On modelling and analysis of healthy and pathological human mitral valves: Two case studies
Source abstract
Abstract
Biomechanical data and related constitutive modelling of the mitral apparatus served as a basis for finite element analyses to better understand the physiology of mitral valves in health and disease. Human anterior and posterior leaflets and chordae tendinae from an elderly heart showing no disease and a hypertrophic obstructive cardiomyopathic heart (HOCM) were mechanically tested by means of uniaxial cyclic extension tests under quasi-static conditions. Experimental data for the leaflets and the chordae tendinae showed highly nonlinear mechanical behaviours and the leaflets were anisotropic. The mitral valve from the HOCM heart exhibited a significantly softer behaviour than the valve from the healthy one. A comparison with porcine data was included because many previous mitral modelling studies have been based on porcine data. Some differences in mechanical response were observed. Material parameters for hyperelastic, transversely isotropic constitutive laws were determined. The experimental data and the related model parameters were used in two finite element studies to investigate the effects of the material properties on the mitral valve response during systole. The analyses showed that during systole the mitral valve from the HOCM heart bulged into the left atrium by taking on the shape of a balloon, whereas the anterior leaflet of the healthy valve remained in the left ventricle.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Elasticity and Material Modeling · Cardiac Structural Anomalies and Repair
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis10.1152/ajpheart.00284.2008 ↗
2. Finite element analysis of the mitral valve
3. Haemodynamic determinants of the mitral valve closure sound: a finite element study10.1007/BF02345218 ↗
4. 3-D computational analysis of the stress distribution on the leaflets after edge-to-edge repair of mitral regurgitation
5. Structural effects of an innovative surgical technique to repair heart valve defects10.1016/j.jbiomech.2004.10.005 ↗
6. Three-dimensional asymmetrical modeling of the mitral valve: A finite element study with dynamic boundaries
7. Finite element analysis of the mitral apparatus: Annulus shape effect and chordal force distribution10.1007/s10237-007-0116-8 ↗
8. Nonlinear solid finite element analysis of mitral valves with heterogeneous leaflets layers10.1007/s00466-008-0310-2 ↗
9. Dynamic finite element implementation of nonlinear, anisotropic hyperelastic biological membranes10.1080/1025584021000048983 ↗
10. A finite shell element for heart mitral valve leaflet mechanics, with large deformations and 3D constitutive material model10.1016/j.jbiomech.2006.01.003 ↗
11. Stress/strain characteristics of porcine mitral valve tissue: Parallel versus perpendicular collagen orientation10.1111/j.1540-8191.1992.tb00777.x ↗
12. Biaxial mechanical behavior of excised porcine mitral valve10.1115/1.2834305 ↗
13. A constitutive law for mitral valve tissue10.1115/1.2834305 ↗
14. Mechanical properties of basal and marginal mitral valve chordae tendineae
15. Prot, V., 2008. Modelling and numerical analysis of the porcine and human mitral apparatus, Ph.D. Thesis, Department of Structural Engineering, NTNU, Norway
16. Mechanics of the human femoral adventitia including the high-pressure response10.1152/ajpheart.00397.2001 ↗
17. Anisotropic mechanical properties of tissue components in human atherosclerotic plaques10.1115/1.1800557 ↗
18. Holzapfel · 2000
19. Transversely isotropic membrane shells with application to mitral valve mechanics. Constitutive modeling and finite element implementation10.1002/nme.1983 ↗
20. Nondestructive analysis of mitral valve collagen fiber orientation
21. Morphology of the human mitral valve: I. Chordae tendinae: A new classification10.1161/01.CIR.41.3.449 ↗
22. The relationship of normal and abnormal microstructural proliferation to the mitral valve closure sound10.1115/1.1835359 ↗
23. Elastic properties of human aortas in relation to age and atherosclerosis: A structural model10.1088/0031-9155/40/10/002 ↗
24. In-vivo dynamic deformation of the mitral valve anterior leaflet10.1016/j.athoracsur.2006.03.117 ↗
25. The material properties of the native porcine mitral valve chordae tendineae: An in vitro investigation10.1016/j.jbiomech.2005.01.024 ↗
26. Diversity of structural mitral valve alterations in hypertrophic cardiomyopathy10.1161/01.CIR.85.5.1651 ↗
27. Determination of material models for arterial walls from uniaxial extension tests and histological structure10.1016/j.jtbi.2005.05.006 ↗
28. On planar biaxial tests for anisotropic nonlinearly elastic solids. A continuum mechanical framework10.1177/1081286507084411 ↗
29. Mitral valve finite-element modelling from ultrasound data: A pilot study for a new approach to understand mitral function and clinical scenarios
30. Papillary muscle traction in mitral valve prolapse: Quantitation by two-dimensional echocardiography10.1016/S0735-1097(10)80274-8 ↗