Breast implant surface texture impacts host tissue response
Source abstract
Abstract
Surface texture of a breast implant influences tissue response and ultimately device performance. Characterizing differences among available surface textures is important for predicting and optimizing performance. Scanning electron microscopy (SEM) and X-ray computed tomography (CT)-imaging were used to characterize the topography and surface area of 12 unique breast implant surface textures from seven different manufacturers. Samples of these surface textures were implanted in rats, and tissue response was analyzed histologically. In separate experiments, the force required to separate host tissue from the implant surface texture was used as a measure of tissue adherence. SEM imaging of the top and cross section of the implant shells showed that the textures differed qualitatively in evenness of the surface, presence of pores, size and openness of the pores, and the depth of texturing. X-ray CT imaging reflected these differences, with the texture surface area of the anterior of the shells ranging from 85 to 551 mm2, which was 8–602% greater than that of a flat surface. General similarities based on the physical structure of the surfaces were noted among groups of textures. In the rat models, with increasing surface texture complexity, there was increased capsule disorganization, tissue ingrowth, and tissue adherence. Surface area and topography of breast implant textures are important factors contributing to tissue ingrowth and adherence. Based on surface area characteristics and measurements, it is possible to group the textures into four classifications: smooth/nanotexture (80–100 mm2), microtexture (100–200 mm2), macrotexture (200–300 mm2), and macrotexture-plus (> 300 mm2).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Breast Implant and Reconstruction · Digital Radiography and Breast Imaging · Breast Cancer Treatment Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. ASTM International · 2011
2. Characterization of breast implant surfaces, shapes, and biomechanics: a comparison of high cohesive anatomically shaped textured silicone, breast implants from three different manufacturers10.1007/s00266-015-0603-8 ↗
3. Textured surface breast implants in the prevention of capsular contracture among breast augmentation patients: a meta-analysis of randomized controlled trials10.1097/01.prs.0000218184.47372.d5 ↗
4. Current implant surface technology: an examination of their nanostructure and their influence on fibroblast alignment and biocompatibility
5. Functional biocompatibility testing of silicone breast implants and a novel classification system based on surface roughness10.1016/j.jmbbm.2017.06.030 ↗
6. Early tissue reaction to textured breast implant surfaces10.1097/00000637-199204000-00010 ↗
7. Histological characterization of human breast implant capsules10.1007/s00266-014-0439-7 ↗
8. Polyurethane-coated breast implants revisited: a 30-year follow-up10.5999/aps.2015.42.2.186 ↗
9. A review of the use of silicone implants in breast surgery10.1586/17434440.2016.1134310 ↗
10. A rat model for capsular contracture: the effects of surface texturing10.1097/00000637-199412000-00005 ↗
11. A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses10.1016/S0294-1260(01)80005-4 ↗
12. Capsular biofilm formation at the interface of textured expanders and human acellular dermal matrix: a comparative scanning electron microscopy study10.1097/PRS.0000000000004216 ↗
13. True synovial metaplasia of breast implant capsules: a light and electron microscopic study10.3109/01913129509014607 ↗
14. Textured silicone breast implant use in primary augmentation: core data update and review10.1097/PRS.0000000000000832 ↗
15. Breast-implant texturing associated with delamination of capsular layers: a histological analysis of the double capsule phenomenon10.1016/j.anplas.2017.02.001 ↗
16. A multi-topographical-instrument analysis: the breast implant texture measurement10.1088/2051-672X/aa7290 ↗
17. A clinical comparison of the tendency to capsular contracture between smooth and textured gel-filled silicone mammary implants10.1097/00006534-199290020-00012 ↗
18. Tendency to capsular contracture around smooth and textured gel-filled silicone mammary implants: a five-year follow-up10.1097/00006534-199711000-00030 ↗
19. Designing implant surface topography for improved biocompatibility10.1586/erd.12.82 ↗
20. Capsular contracture after breast augmentation: an update for clinical practice10.5999/aps.2015.42.5.532 ↗
21. The functional influence of breast implant outer shell morphology on bacterial attachment and growth10.1097/PRS.0000000000004801 ↗
22. Silicon chemistry and silicone breast implants10.1007/s00238-013-0914-4 ↗
23. X-ray microtomography10.1016/j.matchar.2010.09.012 ↗
24. Breast implant design10.21037/gs.2016.11.09 ↗
25. Benefits and limitations of macrotextured breast implants and consensus recommendations for optimizing their effectiveness10.1177/1090820X14538635 ↗
26. The composition and behavior of capsules around smooth and textured breast implants in pigs10.1097/01.prs.0000240878.24213.b7 ↗
27. A pilot quality-of-life instrument for acne rosacea10.1016/j.jaad.2007.01.048 ↗
28. Macrophages, foreign body giant cells and their response to implantable biomaterials10.3390/ma8095269 ↗
29. Characterisation of breast implant surfaces and correlation with fibroblast adhesion10.1016/j.jmbbm.2013.02.005 ↗
30. Spectrum of histological changes reactive to prosthetic breast implants: a clinicopathological study of 84 patients10.1080/00313029600169044 ↗