journal article·2016-10

Tribocorrosion studies of metallic biomaterials: The effect of plasma nitriding and DLC surface modifications

Guo-Hua Zhao, Ragnhild E. Aune, Nuria Espallargas

Publisher page

Abstract

The medical grade pure titanium, stainless steel and CoCrMo alloy have been utilized as biomaterials for load-bearing orthopedic prosthesis. The conventional surgery metals suffer from a combined effect of wear and corrosion once they are implanted, which may significantly accelerate the material degradation process. In this work, the tribocorrosion performance of the metallic biomaterials with different surface modifications was studied in the simulated body fluid for the purpose of investigating the effect of the surface treatments on the tribocorrosion performance and eventually finding the most suitable implantation materials. The metals were subjected to surface modifications by plasma nitriding in different treatment temperatures or physical vapor deposition (PVD) to produce diamond-like carbon (DLC) coating, respectively. The dry wear and tribocorrosion properties of the samples were evaluated by using a reciprocating ball-on-disc tribometer equipped with an electrochemical cell. Prior to the tribocorrosion tests, their electrochemical behavior was measured by the potentiodynamic polarization in phosphate buffer saline (PBS) solution at room temperature. Both stainless steel and CoCrMo after low temperature nitriding kept their passive nature by forming an expanded austenite phase. The DLC coated samples presented the low anodic corrosion current due to the chemical inertness of the carbon layer. During the tribocorrosion tests at open circuit potential, the untreated and low temperature nitrided samples exhibited significant potential drop towards the cathodic direction, which was a result of the worn out of the passive film. Galvanic coupling was established between the depassivated (worn) area and the still passive (unworn) area, making the materials suffered from wear-accelerated corrosion. The DLC coating performed as a solid lubricant in both dry wear and tribocorrosion tests, and the resulting wear after the tests was almost negligible.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Diamond and Carbon-based Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Corrosion performance and mechanical stability of 316L/DLC coating system: Role of interlayers10.1016/j.surfcoat.2010.05.004 ↗
2. Tribocorrosion behaviour of DLC-coated 316L stainless steel10.1016/j.wear.2009.02.006 ↗
3. Tribo-electrochemical technique for studying tribocorrosion behavior of biomaterials10.1016/j.bioeng.2007.07.015 ↗
4. Tribocorrosion of pulsed plasma-nitrided cocrmo implant alloy10.1007/s11249-012-0047-0 ↗
5. Glow discharge nitriding of AISI 316L austenitic stainless steel: Influence of treatment pressure10.1016/j.surfcoat.2005.07.073 ↗
6. Biomedical applications of diamond-like carbon (DLC) coatings: a review10.1016/j.surfcoat.2005.07.077 ↗
7. Electrochemical corrosion behaviour of uncoated and DLC coated medical grade Co28Cr6Mo10.1016/j.surfcoat.2003.06.015 ↗
8. The electrochemical and wear behaviour of amorphous diamond-like carbon coatings and multilayered coatings in aqueous environments10.1016/S0257-8972(96)03054-X ↗
9. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
10. A new experimental technique for quantifying the galvanic coupling effects on stainless steel during tribocorrosion under equilibrium conditions10.1016/j.wear.2013.08.026 ↗
11. A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids10.1016/j.wear.2014.12.030 ↗
12. A quantitative in vitro method to predict the adhesion lifetime of diamond-like carbon thin films on biomedical implants10.1016/j.actbio.2009.05.009 ↗
13. Properties of nitrided layers formed during plasma nitriding of commercially pure Ti and Ti–6Al–4V alloy10.1016/j.surfcoat.2011.10.006 ↗
14. The tribological difference between biomedical steels and CoCrMo-alloys10.1016/j.jmbbm.2012.01.007 ↗
15. Tribocorrosion behavior of plasma nitrided Ti–6Al–4V alloy in neutral NaCl solution10.1016/S0257-8972(01)01309-3 ↗
16. CoCrMo alloy for orthopedic implant application enhanced corrosion and tribocorrosion properties by nitrogen ion implantation10.1016/j.apsusc.2015.04.054 ↗
17. A review of modified DLC coatings for biological applications10.1016/S0925-9635(03)00081-5 ↗
18. Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys10.1002/jbm.a.32851 ↗
19. Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys10.1007/s10856-010-4224-0 ↗
20. Design and mechanical properties of new β type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
21. High intensity plasma ion nitriding of orthopedic materials. Part II. Microstructural analysis10.1016/j.surfcoat.2004.02.047 ↗
22. Plasma nitriding stainless steels at low temperature10.1016/S0257-8972(99)00084-5 ↗
23. Tribocorrosion mechanisms of Ti6Al4V in artificial saliva by zero-resistance ammetry (ZRA) technique10.1007/s40735-015-0008-x ↗
24. Diamond like carbon coatings for potential application in biological implants – a review10.1016/j.triboint.2012.09.006 ↗
25. Reduced tribocorrosion of CoCr alloys in simulated body fluid after nitrogen insertion10.1016/j.surfcoat.2010.01.048 ↗
26. Tribocorrosion of diamond-like carbon deposited on Ti6Al4V10.1007/s11249-009-9408-8 ↗
27. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
28. Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel10.1007/s10856-013-4902-9 ↗
29. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles – a systematic analytical review10.1016/j.actbio.2014.02.027 ↗
30. Wear of CoCrMo alloys used in metal-on-metal hip joints: a tribocorrosion appraisal10.1016/j.wear.2012.11.061 ↗
31. Investigating the correlation between some of the properties of plasma nitrided AISI 316L stainless steel10.1590/S1516-14392013005000081 ↗
32. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
33. Surface modifications for improved wear performance in artificial joints: a review10.1007/s11837-015-1543-0 ↗
34. Tribological behavior of DLC-coated articulating joint implants10.1016/j.actbio.2009.12.019 ↗
35. Amorphous carbon as a bio-mechanical coating – mechanical properties and biological applications10.1016/S0925-9635(00)00462-3 ↗
36. Corrosion and tribological properties and impact fatigue behaviors of TiN- and DLC-coated stainless steels in a simulated body fluid environment10.1016/j.surfcoat.2010.07.111 ↗
37. Wear and corrosion properties of diamond like carbon (DLC) coating on stainless steel, CoCrMo and Ti6Al4V substrates10.1016/j.surfcoat.2015.03.031 ↗
38. Degradation of Zr-based bulk metallic glasses used in load-bearing implants: a tribocorrosion appraisal10.1016/j.jmbbm.2015.12.024 ↗
39. Enhancing the microstructure and properties of titanium alloys through nitriding and other surface engineering methods10.1016/j.surfcoat.2004.07.115 ↗