Mechanical properties, in vitro corrosion resistance and biocompatibility of metal injection molded Ti-12Mo alloy for dental applications
Source abstract
Abstract
A biocompatible Ti-12Mo alloy was fabricated by metal injection moulding (MIM) using non-spherical titanium, molybdenum powders and a purposely designed binder. The density, microstructure and tensile properties were characterized. This was followed by a detailed assessment of its in vitro corrosion and biocompatibility performances, compared with that of two commonly used titanium-based materials extra low interstitial (ELI) Ti-6Al-4V and commercially pure (CP) titanium. The MIM-fabricated Ti-12Mo alloy can achieve a wide range of mechanical properties through controlling sintering process. Specimens sintered at 1400 °C are characterized by fairly uniform near-β microstructure and high relative density of 97.6%, leading to the highest tensile strength of 845.3 ± 21 MPa and elongation of 4.15 ± 0.2% while the highest elastic modulus of 73.2 ± 5.1 GPa. Owing to the formation of protective TiO2-MoO3 passive film, the MIM-fabricated Ti-12Mo alloy exhibits the highest corrosion resistance including the noblest corrosion potential, the lowest corrosion current density and the highest pitting potential in four different electrolytes. The in vitro cytotoxicity test suggests that the MIM-fabricated Ti-12Mo alloy displays no adverse effect on MC3T3-E1 cells with cytotoxicity ranking of 0 grade, which is nearly close to ELI Ti-6Al-4V or CP Ti. These properties together with its easy net-shape manufacturability make Ti-12Mo an attractive new dental implant alloy.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (68)
Show source-provided references
1. Corrosion characterization of titanium alloys applications with changeable Young's modulus for spinal fixation by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
2. ASTM Standards No. G59-97. Standards test method for conducting potentiodynamic polarization resistance measurements. Reapproved in 2003.
3. Electrochemical corrosion behavior of Ti-24Nb-4Zr-8Sn alloy in a simulated physiological environment10.1016/j.apsusc.2011.12.096 ↗
4. Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions10.1016/j.msec.2013.01.036 ↗
5. Beta titanium alloys and their role in the titanium industry10.1007/BF03220742 ↗
6. Investigation of the electrochemical behaviour of TiMo alloys in simulated physiological solutions10.1016/j.electacta.2013.09.116 ↗
7. Experimental study for the influence of twinning on the plastic deformation of pure polycrystalline titanium
8. Metastable beta Ti-Nb-Mo alloys with improved corrosion resistance in saline solution10.1016/j.electacta.2014.06.021 ↗
9. Corrosion behavior of titanium in the presence of calcium phosphate and serum proteins10.1016/j.biomaterials.2005.05.047 ↗
10. Effects of alloying elements on the cytotoxic response of titanium alloys10.1016/j.msec.2010.12.013 ↗
11. Mechanical properties and microstructures of new Ti-Fe-Ta and Ti-Fe-Ta-Zr system alloys
12. Disegi · 2009
13. Characterization of nanocrystalline TiO2-HfO2 thin films prepared by low pressure hot target reactive magnetron sputtering10.1016/j.surfcoat.2005.11.055 ↗
14. Surface characterization of oxides grown on the Ti-13Nb-13Zr alloy and their corrosion protection10.1016/j.corsci.2013.02.007 ↗
15. Microstructure and mechanical behaviour of Ti-6Al-7Nb alloy produced by selective laser melting10.1016/j.matchar.2011.03.006 ↗
16. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
17. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
18. Corrosion of Ti‐15Mo Ti alloy design strategy for biomedical applications10.1016/j.msec.2005.03.007 ↗
19. Electrochemical behaviour of Ti-6Al-4V alloy and Ti in azide and halide solutions10.1016/j.corsci.2011.05.003 ↗
20. Structure and properties of cast binary Ti-Mo alloys10.1016/S0142-9612(99)00114-3 ↗
21. Corrosion-resistant alloys in chloride solution: materials for surgical implants
22. Electrochemical characterisation of passive films on Ti alloys for biomedical under simulated biological conditions10.1016/S0013-4686(02)00029-4 ↗
23. ISO 10993-5: 1999. Biological evaluation of medical devices – Part 5: tests for cytotoxicity: in vitro methods. ANSI/AAMI, Arlington, VA.
24. The application of Ti-15Mo beta titanium alloy in high strength structural orthopaedic applications10.1520/JAI13033 ↗
25. Electrochemical corrosion behavior of biodegradable Mg-Y-RE and Mg-Zn-Zr alloys in Ringer's solution and simulated body fluid10.1016/j.corsci.2014.11.015 ↗
26. Corrosion behaviour of Ti-15Mo alloy for biomedical dental implant applications10.1016/j.jdent.2008.03.007 ↗
27. Electrochemical impedance spectroscopy characterization of passive film formed on the cytotoxic response of titanium implant Ti-6Al-7Nb alloy in Hank's solution10.1023/B:JMSM.0000010097.86245.74 ↗
28. Effect of molybdenum on the microstructure, mechanical properties and corrosion behavior of Ti alloys10.3139/146.111092 ↗
29. Anodic Polarization of titanium and titanium alloys in hydrochloric acid10.1149/1.2411838 ↗
30. Cytotoxicity of titanium and titanium alloying elements10.1177/0022034510363675 ↗
31. Mg-Zr-Sr alloys as biodegradable implant materials10.1016/j.actbio.2012.04.028 ↗
32. Investigation of the dispersion of MoO3 onto the support of mesoporous silica MCM-41
33. Lin, J.H., et al., 2002. Biocompatible low modulus titanium alloy for medical implant. United States patent (6409852).
34. Microstructure and mechanical properties of spark plasma sintered Ti-Mo alloys for dental applications10.1007/s12613-014-0932-7 ↗
35. The role of heat treatment on microstructure and mechanical properties of Ti-13Zr-13Nb alloy fabricated by PIM for biomedical load bearing applications10.1016/j.jmbbm.2011.03.023 ↗
36. Effect of Mo content on electrochemical behaviour of TiMo alloys for dental applications10.1002/maco.201005761 ↗
37. Evaluating electrochemical behaviour of recrystallized titanium alloys in Ringer's solution10.1002/maco.201106185 ↗
38. Electrochemical behaviour of Ti alloys containing Mo and Ta as β-stabilizer elements for dental application10.1016/S1003-6326(13)62936-2 ↗
39. Validation of corrosion rates measured by the Tafel extrapolation method10.1016/j.corsci.2005.05.046 ↗
40. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
41. Mechanical properties of biomedical titanium alloys
42. Processing and mechanical properties of the electrochemical of alloys in simulated physiological porous 316L stainless steel for biomedical applications10.1016/S1003-6326(07)60117-4 ↗
43. Porous NiTi alloy by metal injection moulding/sintering of elemental powders: effect of sintering temperature
44. Point defect model and corrosion of parameters anodic oxide coatings on Ti-6Al-4V10.1016/j.corsci.2008.02.023 ↗
45. Aging characteristics and mechanical property of Ti-29Nb-13Ta-4.6Zr coated with calcium phosphate invert glass-ceramic for biomedical application10.2320/jinstmet1952.67.10_604 ↗
46. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
47. Sintering of aluminiumand its alloys
48. Base metal alloys used for dental restorations and implants10.1016/j.cden.2007.04.001 ↗
49. Corrosion behavior of the Ti-4%Al-4%V alloy in saline boiling nitric acid solutions10.1016/S0010-938X(98)00187-5 ↗
50. In vitro corrosion behaviour of Ti-Nb-Sn shape memory alloys in Ringer's physiological solution
51. Speight · 2005
52. High-strength nanostructured Ti-12Mo alloy from ductile metastable beta state precursor10.1016/j.msea.2010.03.044 ↗
53. Effect of the processing conditions on density, strength and microstructure of Ti-12Mo alloy fabricated by PIM process
54. Electrochemical studies on the stability and corrosion resistance of titanium alloys by electrochemical Ti-5Al-2Nb-1Ta alloy for biomedical applications
55. Characterization of corrosion rates measured by the Tafel extrapolation air-formed surface oxide film on Ti-29Nb-13Ta-4.6Zr alloy surface using XPS and AES10.1016/j.corsci.2008.06.002 ↗
56. Effects of debinding parameters on powder injection molded Ti-6Al-4V/HA composite parts10.1163/156855201750537901 ↗
57. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids10.1016/j.corsci.2012.08.042 ↗
58. Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids10.1016/j.corsci.2009.08.014 ↗
59. Corrosion resistance of titanium dioxide anodic coatings on Ti-6Al-4V10.1002/maco.201407988 ↗
60. Effects of Hf content and immersion time on electrochemical behavior of biomedical Ti-22Nb-xHf alloys in 0.9% NaCl solution10.1002/maco.200805120 ↗
61. Corrosion behaviour of niobium in phosphate buffered saline solutions with different concentrations of bovine serum albumi10.1016/j.corsci.2011.12.039 ↗
62. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: a review10.1016/j.biomaterials.2016.01.012 ↗
63. Corrosion of nickel-based dental casting alloys10.1016/j.dental.2006.06.011 ↗
64. Impacts of trace carbon on the microstructure of as-sintered biomedical Ti-15Mo alloy and titanium alloys in hydrochloric reassessment of the maximum carbon limit10.1016/j.actbio.2013.10.034 ↗
65. Mechanical properties of new type Ti-Fe-Mo-Mn-Nb-Zr titanium alloy
66. Titanium carbide precipitation in Ti-22Nb alloy fabricated by metal injection moulding10.1179/0032589914Z.000000000153 ↗
67. Beta type Ti-Mo alloys with changeable Young's modulus for spinal fixation applications10.1016/j.actbio.2012.02.004 ↗
68. Corrosion behavior of Ti-Mo alloys cold rolled and heat treated10.1016/j.jallcom.2011.03.045 ↗