journal article·2015-02

Pore size and pore shape – but not mesh density – alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair

Spencer P. Lake, Shuddhadeb Ray, Ahmed M. Zihni, Dominic M. Thompson, Jeffrey Gluckstein, Corey R. Deeken

Publisher page

Abstract

Background Over 100 types of soft tissue repair materials are commercially available for hernia repair applications. These materials vary in characteristics such as mesh density, pore size, and pore shape. It is difficult to determine the impact of a single variable of interest due to other compounding variables in a particular design. Thus, the current study utilized prototype meshes designed to evaluate each of these mesh parameters individually. Methods Five prototype meshes composed of planar, monofilament polyethylene terephthalate (PET) were evaluated in this study. The meshes were designed to focus on three key parameters, namely mesh density, pore size, and pore shape. The prototype meshes were implanted in the preperitoneal, retrorectus space in a porcine model of ventral incisional hernia repair, and tissue ingrowth characteristics were evaluated after 90 days. Mesh-tissue composite specimens were obtained from each repair site and evaluated via T-peel mechanical testing. Force-displacement data for each T-peel test were analyzed and five characteristics of tissue ingrowth reported: peak force (fp), critical force (fc), fracture energy (Γc), work (W), and work density (Wden). Hematoxylin and eosin (H&E) stained sections of explanted mesh-tissue composites were also assessed for characteristics of tissue response including cellular infiltration, cell types, inflammatory response, extracellular matrix deposition, neovascularization, and fibrosis, with a composite score assigned to represent overall tissue response. Results The medium-weight, very large pore, hexagonal (MWVLH) mesh performed significantly better than the light-weight, medium pore, diamond (LWMD) mesh for all parameters evaluated (fp, fc, Γc, W, Wden) and trended toward better results than the medium-weight, medium pore, diamond (MWMD) mesh for the majority of the parameters evaluated. When the data for the five meshes was grouped to evaluate mesh density, pore size, and pore shape, differences were more pronounced. No significant differences were observed with respect to mesh density, however significant improvement in mechanical strength of tissue ingrowth occurred as pore size increased from medium to very large. In addition, the hexagonal pores resulted in the strongest tissue ingrowth, followed by the square pores, and finally the diamond pores. Scores for several histological parameters were significantly different for these prototype meshes. For example, the MWVLH mesh showed significantly greater tissue ingrowth by neovascularization histological score than MWMD and MWVLS meshes (p<0.05) and significantly less fibrosis than LWMD and MWVLS meshes (p<0.05). Conclusion Pore shape and pore size significantly altered the mechanical strength of tissue ingrowth and host-site integration in a porcine model of ventral hernia repair, while mesh density had no effect.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hernia repair and management · Intestinal and Peritoneal Adhesions · Surgical Sutures and Adhesives

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Evaluation of composite mesh for ventral hernia repair10.4293/108680811X13071180407393 ↗
2. Cobb · 2009 · 2009
3. The argument for lightweight polypropylene mesh in hernia repair10.1177/155335060501200109 ↗
4. Comparison of contracture, adhesion, tissue ingrowth, and histologic response characteristics of permanent and absorbable barrier meshes in a porcine model of laparoscopic ventral hernia repair10.1007/s10029-011-0854-5 ↗
5. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair10.1016/j.jamcollsurg.2010.09.012 ↗
6. Histologic and biomechanical evaluation of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral incisional hernia repair10.1016/j.jamcollsurg.2011.01.006 ↗
7. Genin G.M., Liu Y. (2013) Models for the mechanics of joining dissimilar materials. In: Structural Interfaces and Attachments in Biology. Thomopoulos S, Birman V, Genin GM, (Eds.), pp. 43–6610.1007/978-1-4614-3317-0_3 ↗
8. Tissue ingrowth and bowel adhesion formation in an animal comparative study: polypropylene versus proceed versus Parietex composite10.1007/s00464-006-9157-9 ↗
9. Evaluation of fenestrated and non-fenestrated biologic grafts in a porcine model of ventral incisional hernia repair10.1007/s10029-010-0684-x ↗
10. Evaluation of fenestrated and non-fenestrated biologic grafts in a porcine model of mature ventral incisional hernia repair10.1007/s10029-010-0684-x ↗
11. The adhesion and surface energy of elastic solids10.1088/0022-3727/4/8/320 ↗
12. Thin-film peeling—the elastic term10.1088/0022-3727/8/13/005 ↗
13. Impact of polymer pore size on the interface scar formation in a rat model10.1006/jsre.2002.6358 ↗
14. The lightweight and large porous mesh concept for hernia repair10.1586/17434440.2.1.103 ↗
15. Central mesh recurrence after incisional hernia repair with Marlex—are the meshes strong enough?10.1007/s100290100023 ↗
16. A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh10.1007/s00464-004-8174-9 ↗
17. Histologic and biomechanical evaluation of a novel macroporous PTFE knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral hernia repair10.1007/s10029-011-0787-z ↗
18. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair10.1002/bjs.4833 ↗
19. Central failures of lightweight monofilament polyester mesh causing hernia recurrence: a cautionary note
20. Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair10.1002/bjs.4387 ↗
21. Ray · 2014
22. The effective work of adhesion
23. Schippers E. Central mesh rupture—myth or real concern? In: Treatment of the Other Hernia. p. 371–376.10.1007/978-3-540-68988-1_37 ↗
24. Functional impairment and complaints following incisional hernia repair with different polypropylene meshes10.1007/s100290100017 ↗
25. Central rupture and bulging of low-weight polypropylene mesh following recurrent incisional sublay hernioplasty10.1007/s10029-013-1197-1 ↗