Planar biaxial testing of soft biological tissue using rakes: A critical analysis of protocol and fitting process
Source abstract
Abstract
Mechanical characterization of soft biological tissue is becoming more and more prevalent. Despite the growing use of planar biaxial testing for soft tissue characterization, testing conditions and subsequent data analysis have not been standardized and vary widely. This also influences the quality of the result of the parameter fitting. Moreover, the testing conditions and data analysis are often not or incompletely reported, which impedes the proper comparison of parameters obtained from different studies. With a focus on planar biaxial tests using rakes, this paper investigates varying testing conditions and varying data analysis methods and their effect on the quality of the parameter fitting results. By means of a series of finite element simulations, aspects such as number of rakes, rakes׳ width, loading protocol, constitutive model, material stiffness and anisotropy are evaluated based on the degree of homogeneity of the stress field, and on the correlation between the experimentally obtained stress and the stress derived from the constitutive model. When calculating the aforementioned stresses, different definitions of the section width and deformation gradient are used in literature, each of which are looked into. Apart from this degree of homogeneity and correlation, also the effect on the quality of the parameter fitting result is evaluated. The results show that inhomogeneities can be reduced to a minimum for wise choices of testing conditions and analysis methods, but never completely eliminated. Therefore, a new parameter optimization procedure is proposed that corrects for the inhomogeneities in the stress field and induces significant improvements to the fitting results. Recommendations are made for best practice in rake-based planar biaxial testing of soft biological tissues and subsequent parameter fitting, and guidelines are formulated for reporting thereof in publications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Gear and Bearing Dynamics Analysis · Mechanical Engineering and Vibrations Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Bonet · 1997
2. A computational test-bed to assess coronary stent implantation mechanics using a population-specific approach10.1007/s13239-012-0104-8 ↗
3. Accurate prediction of stress in fibers with distributed orientations using generalized high-order structure tensors10.1016/j.mechmat.2014.04.006 ↗
4. Characterizing the mechanical contribution of fiber angular distribution in connective tissue10.1007/s10237-010-0194-x ↗
5. Strain uniformity in biaxial specimens is highly sensitive to attachment details10.1115/1.3148467 ↗
6. Arterial clamping10.1016/j.jmbbm.2012.03.010 ↗
7. Simulation of planar soft tissues using a structural constitutive model10.1016/j.jbiomech.2014.03.014 ↗
8. Towards an analytical model of soft biological tissues10.1016/j.jbiomech.2008.05.039 ↗
9. Fung · 1981
10. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
11. Direct measurement of transverse residual strains in aorta10.1152/ajpheart.1996.270.2.H750 ↗
12. A method for measuring strains in soft tissue10.1016/0021-9290(84)90110-6 ↗
13. Holzapfel · 2000
14. Determination of material models for arterial walls from uniaxial extension tests and histological structure10.1016/j.jtbi.2005.05.006 ↗
15. Age estimation based on a combined arteriosclerotic index10.1007/s00414-011-0653-7 ↗
16. Humphrey · 2002
17. Biaxial tension of fibrous tissue10.1115/1.4023503 ↗
18. Avoiding pitfalls in FEA
19. Constitutive equations for fibrous connective tissues10.1016/0021-9290(83)90041-6 ↗
20. Mechanical behavior of coronary stents investigated through the finite element method10.1016/S0021-9290(02)00033-7 ↗
21. On the correct interpretation of measured force and calculation of material stress in biaxial tests10.1016/j.jmbbm.2015.08.019 ↗
22. The biaxial mechanical behaviour of abdominal aortic aneurysm intraluminal thrombus10.1016/j.jbiomech.2014.01.041 ↗
23. Fitting hyperelastic models to experimental data10.1007/s00466-004-0593-y ↗
24. Human thoracic and abdominal aortic aneurysmal tissues10.1016/j.jmbbm.2014.10.003 ↗
25. Multiaxial mechanical behavior of biological materials10.1146/annurev.bioeng.5.011303.120714 ↗
26. Biaxial mechanical evaluation of planar biological materials
27. Non-invasive, energy-based assessment of patient-specific material properties of arterial tissue
28. Multiaxial mechanical response and constitutive modeling of esophageal tissues10.1016/j.actbio.2013.07.041 ↗
29. Compliance and diameter in the human abdominal aorta—influence of age and sex10.1016/S0950-821X(05)80718-2 ↗
30. Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues10.1115/1.1933931 ↗
31. A planar biaxial constitutive relation for the luminal layer of intra-luminal thrombus in abdominal aortic aneurysms10.1016/j.jbiomech.2006.05.011 ↗
32. Boundary conditions during biaxial testing of planar connective tissues. Part 1
33. Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening10.1016/j.jmbbm.2012.03.012 ↗
34. A generalized method for the analysis of planar biaxial mechanical data using tethered testing configurations10.1115/1.4029266 ↗