Tissue engineering provides a promising alternative for small diameter vascular grafts, especially with the self-assembly method. It is crucial that these grafts possess mechanical properties that allow them to withstand physiological flow and pressure without being damaged. Therefore, an accurate assessment of their mechanical properties, especially the burst pressure, is essential prior to clinical release. In this study, the burst pressure of self-assembled tissue-engineered vascular substitutes was first measured by the direct method, which consists in pressurizing the construct with fluid until tissue failure. It was then compared to the burst pressure estimated by Laplace׳s law using data from a ring tensile test. The major advantage of this last method is that it requires a significantly smaller tissue sample. However, it has been reported as overestimating the burst pressure compared to a direct measurement. In the present report, it was found that an accurate estimation of the burst pressure may be obtained from a ring tensile test when failure internal diameter is used as the diameter parameter in Laplace׳s law. Overestimation occurs with the method previously reported, i.e. when the unloaded internal diameter is used for calculations. The estimation of other mechanical properties was also investigated. It was demonstrated that data from a ring tensile test provide an accurate estimate of the failure strain and the stiffness of the constructs when compared to measurements with the direct method.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Aortic Disease and Treatment Approaches

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. ANSI/AAMI/ISO 7198:1998,2001, R2010. Cardiovascular Implants – Tubular Vascular Protheses, 2010
2. Incorporation of intact elastin scaffolds in tissue-engineered collagen-based vascular grafts10.1089/ten.2004.10.1526 ↗
3. Viscoelastic testing methodologies for tissue engineered blood vessels10.1115/1.2073487 ↗
4. Human fibroblast-derived ECM as a scaffold for vascular tissue engineering10.1016/j.biomaterials.2012.09.015 ↗
5. Relation of Structure to function of the wall of blood vessels10.1152/physrev.1954.34.4.619 ↗
6. Investigation of a small-diameter decellularised artery as a potential scaffold for vascular tissue engineering; biomechanical evaluation and preliminary cell seeding10.1016/j.jmbbm.2012.06.001 ↗
7. The effects of preconditioning strain on measured tissue properties10.1016/j.jbiomech.2009.03.023 ↗
8. Eagle · Circulation · 2004 · 110 · e340
9. A novel single-step self-assembly approach for the fabrication of tissue-engineered vascular constructs10.1089/ten.tea.2009.0313 ↗
10. Heart disease and stroke statistics--2013 update: a report from the American Heart Association
11. Saphenous vein graft failure after coronary artery bypass surgery: pathophysiology, management, and future directions10.1097/SLA.0b013e318288c38d ↗
12. Tissue engineering of small caliber vascular grafts10.1016/S1010-7940(01)00706-0 ↗
13. Artificial blood vessel: the Holy Grail of peripheral vascular surgery10.1016/j.jvs.2004.12.026 ↗
14. Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery10.1016/j.biomaterials.2008.11.011 ↗
15. Engineering functionally graded tissue engineering scaffolds10.1016/j.jmbbm.2007.11.002 ↗
16. A Computer-controlled apparatus for the characterization of mechanical and viscoelastic properties of tissue-engineered vascular constructs10.1007/s13239-011-0033-y ↗
17. Human tissue-engineered blood vessels for adult arterial revascularization10.1038/nm1364 ↗
18. A completely biological tissue-engineered human blood vessel
19. Analysis of the uniaxial and multiaxial mechanical response of a tissue-engineered vascular graft10.1089/ten.tea.2012.0075 ↗
20. Tri-layered vascular grafts composed of polycaprolactone, elastin, collagen, and silk: optimization of graft properties10.1016/j.jmbbm.2012.02.026 ↗
21. Minimally invasive direct redo coronary artery bypass grafting
22. Nichols · 2011
23. Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique10.1016/j.biomaterials.2007.10.044 ↗
24. Non-linear viscoelastic laws for soft biological tissues10.1016/S0997-7538(00)00202-3 ↗
25. Manufacture of small calibre quadruple lamina vascular bypass grafts using a novel automated extrusion-phase-inversion method and nanocomposite polymer10.1016/j.jbiomech.2009.01.003 ↗
26. Critical parameter of burst pressure measurement in development of bypass grafts is highly dependent on methodology used10.1016/j.jvs.2006.07.023 ↗
27. Decellularized vein as a potential scaffold for vascular tissue engineering10.1016/j.jvs.2004.03.033 ↗
28. Mechanical strain-stimulated remodeling of tissue-engineered blood vessel constructs10.1089/107632703768247359 ↗
29. Mechanical characterization of a customized decellularized scaffold for vascular tissue engineering10.1016/j.jmbbm.2011.12.003 ↗
30. A bilayered elastomeric scaffold for tissue engineering of small diameter vascular grafts10.1016/j.actbio.2009.06.026 ↗
31. Fabrication of cell microintegrated blood vessel constructs through electrohydrodynamic atomization10.1016/j.biomaterials.2007.02.012 ↗
32. Review: advances in vascular tissue engineering using protein-based biomaterials10.1089/ten.2007.0196 ↗
33. Dynamic straining combined with fibrin gel cell seeding improves strength of tissue-engineered small-diameter vascular grafts10.1089/ten.tea.2008.0183 ↗
34. Implantable arterial grafts from human fibroblasts and fibrin using a multi-graft pulsed flow-stretch bioreactor with noninvasive strength monitoring10.1016/j.biomaterials.2010.09.019 ↗
35. Laplace׳s law: what it is about, where it comes from, and how it is often applied in physiology10.1109/MPUL.2011.942054 ↗
36. Influence of cyclic mechanical stretch and tissue constraints on cellular and collagen alignment in fibroblast-derived cell sheets10.1089/ten.tec.2012.0423 ↗
37. Comparative effectiveness of revascularization strategies10.1056/NEJMoa1110717 ↗