Tribocorrosion behavior of beta titanium biomedical alloys in phosphate buffer saline solution
Source abstract
Abstract
The tribo-electrochemical behavior of different β titanium alloys for biomedical applications sintered by powder metallurgy has been investigated. Different mechanical, electrochemical and optical techniques were used to study the influence of the chemical composition, Sn content, and the electrochemical conditions on the tribocorrosion behavior of those alloys Ti30NbxSn alloys (where "x" is the weight percentage of Sn content, 2% and 4%). Sn content increases the active and passive dissolution rate of the titanium alloys, thus increasing the mechanically activated corrosion under tribocorrosion conditions. It also increases the mechanical wear of the alloy. Prevailing electrochemical conditions between -1 and 2V influences the wear accelerated corrosion by increasing it with the applied potential and slightly increases the mechanical wear of Ti30Nb4Sn. Wear accelerated corrosion can be predicted by existing models as a function of electrochemical and mechanical parameters of the titanium alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants10.1088/0022-3727/46/40/404001 ↗
2. The investigation of the tribocorrosion properties of DLC coatings deposited on Ti6Al4V alloys by CFUBMS10.1016/j.porgcoat.2011.10.023 ↗
3. Corrosion behavior of β titanium alloys for biomedical applications10.1016/j.msec.2011.02.005 ↗
4. Tribocorrosion behaviour of DLC-coated 316L stainless steel10.1016/j.wear.2009.02.006 ↗
5. Influence of the microstructure and topography on the barrier properties of oxide scales generated on blasted Ti6Al4V surfaces10.1016/j.actbio.2011.02.040 ↗
6. Effects of alloying elements on the cytotoxic response of titanium alloys10.1016/j.msec.2010.12.013 ↗
7. Topographical control of cells10.1016/S0142-9612(97)00144-0 ↗
8. Electrochemical behaviour of near-beta titanium biomedical alloys in phosphate buffer saline solution
9. Processing and characterization of β-Ti alloys by means of powder metallurgy processing and blender elemental10.4028/www.scientific.net/MSF.727-728.61 ↗
10. Properties of solid core and porous surface Ti–6Al–4V implants manufactured by powder metallurgy10.1016/j.jallcom.2006.12.143 ↗
11. Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques10.1016/j.wear.2012.04.014 ↗
12. Tribocorrosion behavior of plasma nitrided Ti–6Al–4V alloy in neutral NaCl solution10.1016/S0257-8972(01)01309-3 ↗
13. Preparation and properties of mechanically alloyed and electrochemically etched porous Ti–6Al–4V10.1016/j.elecom.2009.07.014 ↗
14. Tribocorrosion behaviour of Fe–17Cr stainless steel in acid and alkaline solutions10.1016/S0301-679X(99)00051-1 ↗
15. Mechanical properties of fully porous and porous-surfaced Ti–6Al–4V implants fabricated by electro-discharge-sintering10.1016/j.jmatprotec.2007.04.102 ↗
16. Electrochemical methods in tribocorrosion: a critical appraisal10.1016/S0013-4686(01)00679-X ↗
17. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
18. Tribocorrosion mechanisms of Ti6Al4V biomedical alloys in artificial saliva with different pHs10.1088/0022-3727/46/40/404003 ↗
19. Effects of aging heat treatment on the microstructure of Ti–Nb and Ti–Nb–Sn alloys employed as biomaterials10.4028/www.scientific.net/AMR.324.61 ↗
20. Effects of double aging heat treatment on the microstructure, Vickers hardness and elastic modulus of Ti–Nb alloys10.1016/j.matchar.2011.04.015 ↗
21. Influence of microstructure and texture on the corrosion and tribocorrosion behavior of Ti–6Al–4V10.1016/j.triboint.2009.12.055 ↗
22. Significance of tribocorrosion in biomedical applications: overview and current status10.1155/2009/250986 ↗
23. Electrochemical properties, chemical composition and thickness of passive film formed on novel Ti–20Nb–10Zr–5Ta alloy10.1016/j.electacta.2013.03.086 ↗
24. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
25. Sliding tribo-corrosion of passive metals: mechanisms and modeling
26. The role of passive oxide films on the degradation of steel in tribocorrosion systems10.1016/S0043-1648(99)00056-3 ↗
27. The bone tissue compatibility of a new TiNbSn alloy with a low Young׳s modulus10.1016/j.actbio.2011.02.008 ↗
28. Tribocorrosion behavior of β titanium alloys in physiological solutions containing synovial components10.1016/j.msec.2010.10.021 ↗
29. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti29Nb13Ta4.6Zr10.1016/S0142-9612(03)00069-3 ↗
30. Green tribology: principles, research areas and challenges10.1098/rsta.2010.0200 ↗
31. evaluation of passive film growth models with the electrochemical quartz crystal microbalance on PVD deposited Cr10.1149/1.1394025 ↗
32. Electrochemical simulation of the current and potential response in sliding tribocorrosion10.1007/s11249-012-0022-9 ↗
33. EBSD, SEM and FIB characterisation of subsurface deformation during tribocorrosion of stainless steel in sulphuric acid10.1016/j.wear.2010.04.023 ↗
34. Wear and tribocorrosion behaviour of 304L SS, Zr-702, Zircaloy-4 and Ti-grade210.1016/j.wear.2013.11.051 ↗
35. Stachowiak · 2011
36. The effect of mechanical and electrochemical parameters on the tribocorrosion rate of stainless steel in sulphuric acid10.1016/S0043-1648(03)00085-1 ↗
37. Effect of electrochemical potential on tribocorrosion behavior of low temperature plasma carburized 316L stainless steel in 1M H2SO4 solution10.1016/j.surfcoat.2011.03.048 ↗
38. Production of new titanium alloy for orthopedic implants10.1016/j.msec.2004.08.011 ↗
39. Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO3 solutions10.1016/j.corsci.2011.08.041 ↗
40. Effects of Sn content on the microstructure, mechanical properties and biocompatibility of Ti–Nb–Sn/hydroxyapatite biocomposites synthesized by powder metallurgy10.1016/j.matdes.2013.01.012 ↗
41. Effects of titanium surface topography on bone integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
42. Biocompatibility and osteoconduction of active porous calcium–phosphate films on a novel Ti–3Zr–2Sn–3Mo–25Nb biomedical alloy10.1016/j.colsurfb.2011.02.025 ↗
43. Tribological behavior study on TiNbSn/hydroxyapatite composites in simulated body fluid solution10.1016/j.jmbbm.2012.02.017 ↗