journal article·2017-04Open access

Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium

María Sol Cabrera, Cees W.J. Oomens, Frank P.T. Baaijens

Abstract

A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Cardiac Structural Anomalies and Repair

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Finite element modeling of a novel self-expanding endovascular stent method in treatment of aortic aneurysms10.1038/srep03630 ↗
2. Shape-memory alloys: modelling and numerical simulation of the finite-strain superelastic behavior10.1016/S0045-7825(96)01147-4 ↗
3. Deployment of a self-expanding stent inside an artery: a finite element analysis10.1016/j.matdes.2012.05.019 ↗
4. Effect of stent radial force on stress pattern after deployment: a finite element study10.1007/s11665-014-0913-z ↗
5. Mechanical analysis of ovine and pediatric pulmonary artery for heart valve stent design10.1016/j.jbiomech.2013.04.020 ↗
6. Filling the void: a coalescent numerical and experimental technique to determine aortic stent graft mechanics10.1016/j.jbiomech.2013.07.010 ↗
7. Transcatheter implantation of homologous “off-the-shelf” tissue-engineered heart valves with self-repair capacity: long-term functionality and rapid In vivo remodeling in sheep10.1016/j.jacc.2013.09.082 ↗
8. Physical properties of endovascular stents: an experimental comparison10.1016/S1051-0443(07)61620-0 ↗
9. A comparison of balloon- and self-expanding stents10.1080/136457002760273386 ↗
10. Overview߭of߭superelastic stent design10.1080/13645700009169654 ↗
11. Duerig, T.W., Stoeckel, D. Johnson, D., 2003. SMA: Smart Materials for Medical Applications. In: Proceedings of SPIE 4763, European Workshop on Smart Structures in Engineering and Technology, 7 (March 12, 2003); http://dx.doi.org/10.1117/12.508666.10.1117/12.508666 ↗
12. Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent10.1016/j.jmbbm.2012.02.006 ↗
13. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
14. Guidance for Industry and FDA Staff—Non-Clinical Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems [Document issued on: April 18, 2010]); available online from: 〈http://www.fda.gov/downloads/medical%20devices/deviceregulationandguidance/guidancedocuments/ucm071986.pdf〉.
15. Percutaneous implantation of the Edwards SAPIEN pulmonic valve: initial results in the first 22 patients10.1007/s00392-012-0503-8 ↗
16. In vitro evaluation of the radial and axial force of self-expanding esophageal stents10.1055/s-0033-1344985 ↗
17. Clinical Endoscopy Measurement of radial and axial forces of biliary self-expandable metallic stents10.1016/j.gie.2008.09.032 ↗
18. Ageing and vascular ageing10.1136/pgmj.2005.036053 ↗
19. The mechanical properties of endovascular stents: an in vitro assessment10.1007/s10558-010-9097-9 ↗
20. Multiple repressor path-ways contribute to phenotypic switching of vascular smooth muscle cells10.1152/ajpcell.00394.2006 ↗
21. Computational mechanics of Nitinol stent grafts10.1016/j.jbiomech.2008.05.032 ↗
22. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia10.1016/S0735-1097(97)00450-6 ↗
23. Control of phenotypic plasticity of smooth muscle cells by bone morphogenetic protein signaling through the myocardin-related transcription factors10.1074/jbc.M708137200 ↗
24. Percutaneous pulmonary valve replacement: autologous tissue-engineered valved stents10.1093/cvr/cvq212 ↗
25. Okamoto, Y., Tanaka, T., Kobashi, H., Iwasaki, K. Umezu, M., et al., 2009. In-vitro evaluation method to measure the radial force of various stents. In: ICBME 2008 Proceedings, vol. 23, pp. 1053–1056.10.1007/978-3-540-92841-6_259 ↗
26. An engineering review of transcatheter aortic valve technologies10.1007/s13239-010-0008-4 ↗
27. A survivor of late prosthesis migration and rotation following percutaneous transcatheter aortic valve implantation10.1093/ejcts/ezr195 ↗
28. Rosengart, T.K., Feldman, T., Borger, M.A., Vassiliades, T.A., Marc, A., et al., 2008. Percutaneous and minimally invasive valve procedures: a scientific statement from the American Heart Association Council on Cardiovascular Surgery and Anesthesia, Council on Clinical Cardiology, Functional Genomics and Translational Biology Interdisciplinary Working Group, and Quality of Care and Outcomes Research Interdisciplinary Working Group. Circulation; 117: 1750-67.10.1161/CIRCULATIONAHA.107.188525 ↗
29. Minimally-invasive autologous tissue engineered heart valve10.1016/j.jacc.2010.04.024 ↗
30. Shanmugam, K., Viswanatha, N., Ramanathan, R.K., Rajan, J., Selvam, S., et al., 2014. Design optimization of thoracic endovascular stent graft (EVSG). IFMBE Proceedings; 43:352–355.10.1007/978-3-319-02913-9_90 ↗
31. A planar approach for manufacturing cardiac stents: design, fabrication, and mechanical evaluation10.1109/JMEMS.2004.838357 ↗
32. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model10.1016/S0142-9612(02)00030-3 ↗
33. Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)10.1016/j.medengphy.2012.04.009 ↗
34. Percutaneous pulmonary valve implantation in the young 2-Year Follow-Up
35. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep10.1371/journal.pone.0100065 ↗