Failure load and stress analysis of orthodontic miniscrews with different transmucosal collar diameter
Source abstract
Abstract
Miniscrews have been introduced in orthodontics as temporary anchorage devices (TADs), in order to move the correct teeth and avoid other elements to slide toward a wrong direction. Moreover the ease of use of TADs encouraged clinicians to use miniscrews also for non-conventional purposes, as fixation in mandibular fracture, mini-implant supported temporary pontics, miniscrew-assisted rapid palatal expanders and distalizers. These applications develop higher forces, so TAD fracture can be an unwanted complication. Some authors analyzed torsional loads but no studies measured forces required to bend the screws and ultimate flexural strength. Accordingly, in the present report, Ti-6Al-4V TADs were mechanically evaluated. Seven different diameters of screws were tested: 1.3 mm (Aarhus Screw, Medicon), 1.5 mm (Spider Screw, HDC), 1.6 mm (Aarhus Screw, Medicon), 1.7 mm (Ortho Easy, Forestadent), 1.8 mm (Ortho Implant, 3 M), 1.9 mm (Spider Screw, HDC) and 2.0 mm (Storm, Kristal). The forces to bend the titanium TADs were measured at 0.1 mm, 0.2 mm magnitude of deflections and at maximum load (as peak before screw fracture) in air with a universal testing machine. Statistical analyses were performed. Both at 0.1 mm and at 0.2 mm deflections and at maximum load, the significantly highest forces were reported with 1.7, 1.8, 1.9, and 2.0 mm TADs. The lowest values were reported with 1.6, 1.5, and 1.3 mm mini-implants. No significant differences were reported between 1.6 mm and 1.7 mm screws. It was found that load values in N versus stress in MPa were not fully comparable when screws with small and larger diameter were compared. Therefore, when placing a miniscrew for applications that need maximum shear bending resistance, these results would be considered in order to reduce risk of unwanted fracture.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Facial Trauma and Fracture Management · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. The span length and cross-sectional design affect values of strength10.1016/j.dental.2004.05.009 ↗
2. Generic finite element models of orthodontic mini-implants: are they reliable?10.1016/j.jbiomech.2015.08.015 ↗
3. Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during en-masse retraction: a systematic review and meta-analysis10.1016/j.ajodo.2016.08.029 ↗
4. A 12 month clinical study of bond failures of recycled versus new stainless steel orthodontic brackets10.1093/ejo/26.4.449 ↗
5. Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring10.1016/j.ajodo.2005.09.036 ↗
6. Force levels of fiber-reinforced composites and orthodontic stainless steel wires: a 3-point bending test10.1016/j.ajodo.2006.01.047 ↗
7. The dynforce archwire
8. A simple way to intrude overerupted upper second molars with miniscrews10.1111/jopr.12057 ↗
9. Scar formation and revision after the removal of orthodontic miniscrews10.4041/kjod.2015.45.3.146 ↗
10. An upper-molar distalizer with palatal miniscrew anchorage
11. Pain and discomfort following insertion of miniscrews and premolar extractions: a randomized controlled trial10.2319/123115-899.1 ↗
12. Peak torque values at fracture of orthodontic miniscrews
13. Risks and complications of orthodontic miniscrews10.1016/j.ajodo.2006.04.027 ↗
14. Risks and complications of miniscrew anchorage in clinical orthodontics10.1016/j.jdsr.2014.05.001 ↗
15. Endodontic and surgical treatment of root damage caused by orthodontic miniscrew placement10.1016/j.joen.2013.04.037 ↗
16. Temporary anchorage devices for tooth movement: a review and case reports10.1902/jop.2006.060127 ↗
17. Risk factors associated with the failure of miniscrews – a ten-year cross sectional study10.1590/1807-3107BOR-2016.vol30.0124 ↗
18. Can we close large prosthetic space with orthodontics?
19. The use of miniscrews in orthodontics: a review of selected clinical applications10.1308/205016816820209569 ↗
20. Maxillary sinus perforation by orthodontic anchor screws10.2334/josnusd.57.95 ↗
21. An XPS and SEM evaluation of six chemical and physical techniques for cleaning of contaminated titanium implants10.1034/j.1600-0501.1998.090306.x ↗
22. Surface deterioration and elemental composition of retrieved orthodontic miniscrews10.1016/j.ajodo.2014.10.034 ↗
23. A critical view on biaxial and short-beam uniaxial flexural strength tests applied to resin composites using Weibull, fractographic and finite element analyses10.1016/j.dental.2009.09.002 ↗
24. Use of orthodontic mini-implants for maxillomandibular fixation in mandibular fracture10.1055/s-0031-1293522 ↗
25. Preliminary fabrication and characterization of electron beam melted Ti-6Al-4V customized dental implant10.1016/j.sjbs.2016.05.001 ↗
26. Mechanical loading of orthodontic miniscrews – significance and problems: an experimental study10.1515/BMT.2008.038 ↗
27. Orthodontics. Part 9: anchorage control and distal movement10.1038/sj.bdj.4811031 ↗
28. Extrusion of severely impacted mandibular first molar using partial orthodontics and temporary anchorage miniscrews
29. Orthodontics: bracket materials, adhesives systems, and their bond strength10.1155/2016/1329814 ↗
30. Reconditioning of self-ligating brackets10.2319/033011-227.1 ↗
31. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination10.1155/2013/180137 ↗
32. Placement and removal torque values of orthodontic miniscrew implants10.1016/j.ajodo.2010.11.017 ↗
33. Miniscrew-assisted rapid palatal expander (MARPE): the quest for pure orthopedic movement10.1590/2177-6709.21.4.017-023.oin ↗
34. Evaluation of optimal length and insertion torque for miniscrews10.1016/j.ajodo.2013.03.021 ↗
35. Stress analysis of short beams10.2514/3.9455 ↗
36. Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews – an in vitro study10.1186/s13005-017-0143-3 ↗
37. Bone anchor systems for orthodontic application: a systematic review10.1016/j.ijom.2012.05.011 ↗
38. In vitro cytotoxicity and surface topography evaluation of additive manufacturing titanium implant materials10.1007/s10856-017-5863-1 ↗
39. In vitro evaluation of cytotoxicity and genotoxicity of a commercial titanium alloy for dental implantology10.1016/j.mrgentox.2010.06.013 ↗
40. A randomized controlled trial of self-perceived pain, discomfort, and impairment of jaw function in children undergoing orthodontic treatment with fixed or removable appliances10.2319/040215-219.1 ↗
41. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study10.1093/ejo/cjq151 ↗
42. Mini-implant-supported temporary pontics
43. Distal movement of maxillary molars using miniscrew anchorage in the buccal interradicular region10.2319/020408-68.1 ↗