3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses
Source abstract
Abstract
The use of 3D technologies is progressing in the dental field. However, little is known about the biomechanical behavior of the additive manufacturing of full-arch fixed dental prostheses (FAFDPs) for the establishment of clinical protocols. We investigated the influence of three CAD/CAM technologies: milling (control), Selective Laser Melting (SLM) and Electron Beam Melting (EBM) for FAFDP manufacturing. Also, the effects of ceramic veneer and spark erosion on marginal misfits of FAFDPs, the stability of prosthetic screws, strain and stress on the implant-supported system, as well as the effect of chewing simulation on screw stability were evaluated. Fifteen Ti-6Al-4V alloy FAFDPs were obtained by means of CAD/CAM systems: milling, SLM and EBM (n = 5/group). The marginal misfit was analyzed according to the single-screw test protocol. Screw stability was analyzed by screw-loosening torque. Strain-gauge analysis investigated the strain on the mini-abutment analog, and photoelastic analysis investigated the stress on the peri-implant region. Subsequently, all frameworks underwent ceramic veneer and spark erosion procedures. Marginal misfit, screw-loosening and strain and stress analyses were assessed after each evaluation time: initial, ceramic veneer and spark erosion. Finally, all prostheses were subjected to 106 mechanical cycles (2 Hz/150 N), and screw-loosening was re-evaluated. Data were subjected to two-way ANOVA for repeated measures, and the Bonferroni test as a post hoc technique (α = 0.05). At the initial time, the milling group presented the lowest marginal misfit (p < 0.001). Ceramic veneer did not alter marginal misfit for all groups (p > 0.05); spark erosion decreased the misfit values for the SLM and EBM groups (p < 0.05). Evaluation time did not alter screw-loosening values for all groups (p = 0.191), although the milling group presented the highest screw-loosening values (p < 0.05). Ceramic veneer and spark erosion reduced strain in the components regardless of the manufacturing technology used (p < 0.05). The milling group presented the lowest stress values regardless of evaluation time (p = 0.001), and lower stress values were found after spark erosion regardless of the manufacturing group (p = 0.016). In conclusion, although milled frameworks exhibited the best biomechanical behavior, frameworks manufactured by additive technologies presented acceptable values of screw-loosening torque, strain and stress. Ceramic veneer did not negatively interfere in the biomechanical tests of the study, and clinically acceptable marginal misfit was achieved after spark erosion. Therefore, such 3D printing technologies seem to be feasible for the manufacturing of full-arch implant-supported frameworks.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (54)
Show source-provided references
1. Fit of CAD/CAM implant frameworks: a comprehensive review10.1563/AAID-JOI-D-12-00117 ↗
2. Effect of vertical misfit on strain within screw-retained implant titanium and zirconia frameworks10.1016/j.jpor.2011.09.001 ↗
3. Influence of vertical misfit of titanium and zirconia frameworks on peri-implant strain
4. Changes in prosthetic screw stability because of misfit of implant-supported prostheses
5. ASTM International · 2009
6. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations10.1038/sj.bdj.2008.350 ↗
7. Fit and stability of screw-retained implant-supported frameworks under masticatory simulation: influence of cylinder type10.1111/jopr.12349 ↗
8. The effect of casting and masticatory simulation on strain and misfit of implant-supported metal frameworks10.1016/j.msec.2016.02.035 ↗
9. Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: a prototyping guided 3D-FEA study10.1016/j.msec.2016.07.059 ↗
10. Influence of the casting technique and dynamic loading on screw detorque and misfit of single unit implant-supported prostheses10.3109/00016357.2012.690528 ↗
11. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives10.1016/S0022-3913(13)60318-2 ↗
12. Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: a comparative in vitro study10.1016/j.dental.2018.03.009 ↗
13. Osseointegration and its experimental background10.1016/S0022-3913(83)80101-2 ↗
14. Torque required to loosen single-tooth implant abutment screws before and after simulated function
15. The effect of repeated firings and strength on marginal distortion in two ceramometal systems10.1016/0022-3913(81)90035-4 ↗
16. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method10.1016/j.prosdent.2014.09.021 ↗
17. Tightening characteristics for screwed joints in osseointegrated dental implants10.1016/0022-3913(94)90443-X ↗
18. Manufacturing of metal frameworks for full-arch dental restoration on implants: a comparison between milling and a novel hybrid technology10.1111/jopr.13067 ↗
19. Precision fit of screw-retained implant-supported fixed dental prostheses fabricated by CAD/CAM, copy-milling and conventional methods10.11607/jomi.5023 ↗
20. Correlation between vertical misfits and stresses transmitted to implants from metal frameworks10.1016/j.jbiomech.2011.03.032 ↗
21. Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses10.1111/j.1532-849X.2012.00835.x ↗
22. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions10.1016/j.prosdent.2013.07.024 ↗
23. Distortion related to margin design in porcelain-fused-to-metal restorations10.1016/0022-3913(80)90178-X ↗
24. A 2003 update of bone physiology and Wolff’s Law for Clinicians
25. Additive manufacturing processes: selective laser melting
26. Torque loss under mechanical cycling of long-span zirconia and titanium-cemented and screw-retained implant-supported CAD/CAM frameworks10.1111/clr.12286 ↗
27. International Organization for Standardization
28. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup
29. New 3D technologies applied to assess the long-term clinical effects of misfit of the full jaw fixed prosthesis on dental implants10.1111/clr.12490 ↗
30. Clinical methods for evaluating implant framework fit10.1016/S0022-3913(99)70229-5 ↗
31. In vitro precision of fit of computeraided designed and computer-aided manufactured titanium screw-retained fixed dental prostheses before and after ceramic veneering10.1111/clr.12299 ↗
32. CAD/CAM fabrication accuracy of long- vs short-span implant supported FDPs10.1111/clr.12522 ↗
33. Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD/CAM-based processing techniques10.3390/ma9070596 ↗
34. Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques10.4047/jap.2013.5.2.179 ↗
35. Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies10.1016/j.prosdent.2014.07.002 ↗
36. Effect of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with different CAD-CAM technologies
37. Misfit of pure titanium frameworks: effect of veneer coverage and spark erosion process10.3109/00016357.2011.554860 ↗
38. Dimensional precision of implant-supported frameworks fabricated by 3D printing10.1016/j.prosdent.2019.01.019 ↗
39. Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks10.1016/j.prosdent.2016.06.011 ↗
40. Influence of spark erosion on the fit of screw-retained Co-Cr fixed complete denture frameworks veneered with different materials10.1016/j.prosdent.2017.07.003 ↗
41. A comparison of the quality of dental crowns from TI-6AL-4V and CoCr alloys made with slm technology
42. Preliminary fabrication and characterization of electron beam melted Ti-6Al-4V customized dental implant10.1016/j.sjbs.2016.05.001 ↗
43. Discrepancy of complete-arch titanium frameworks manufactured using selective laser melting and electron beam melting additive manufacturing technologies10.1016/j.prosdent.2018.02.010 ↗
44. 3D metal printing – additive manufacturing technologies for frameworks of implant-borne fixed dental prosthesis
45. Accuracy of three corrective techniques for implant bar fabrication10.1067/mpr.2000.111494 ↗
46. Influence of laser-welding and electroerosion on passive fit of implant-supported prosthesis
47. Biomechanical considerations in osseointegrated prostheses10.1016/0022-3913(83)90361-X ↗
48. Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures10.1590/S0103-64402010000100002 ↗
49. Computer-aided design and fabrication of dental restorations: current systems and future possibilities10.14219/jada.archive.2006.0389 ↗
50. The application of rapid prototyping in prosthodontics10.1111/j.1532-849X.2012.00888.x ↗
51. Additively manufactured titanium and cobalt-chromium implant frameworks: fit and effect of ceramic veneering10.11607/jomi.6028 ↗
52. Preliminary fabrication of thin-wall structure of Ti6Al4V for dental restoration by electron beam melting10.1108/13552541211218180 ↗
53. Effects of processing parameters on surface roughness of additive manufactured Ti-6Al-4V via electron beam melting10.3390/ma10101121 ↗
54. Stress fatigue: basic principles and prosthodontic implications