Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution

Gustavo Dartora, Gabriel Kalil Rocha Pereira, Rodrigo Varella de Carvalho, Camila Pauleski Zucuni, Luiz Felipe Valandro, Paulo Francisco Cesar, Ricardo Armini Caldas, Atais Bacchi

Publisher page

Abstract

This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars were randomly assigned into 03 groups (n = 16) and restored with endocrowns (LD - lithium disilicate glass-ceramic or PICN - polymer-infiltrated ceramic network) or with direct composite restorations. Fatigue testing followed a step-stress approach (initial maximum load of 200 N and 5000 cycles, incremental step load of 200N and 10,000 cycles/step, being the specimens loaded until failure or to a maximum of 135,000 cycles at 2800 N). The fatigue failure load and number of cycles until failure were recorded and statistically analyzed. Fractographic and finite element (FEA) analyzes were conducted as well. There were no differences in fatigue failure load, number of cycles until fracture and mean survival probabilities among groups. However, indirect endocrowns had higher mechanical structural reliability, and LD restorations lasted more time before start to failing. FEA showed that the stress concentration in tooth tissues was higher for the resin composite, followed by PICN and LD in a decreasing order. Almost all fractures were restricted to the restorative material (without tooth involvement), and origins were identified at occlusal surface. The type of restoration did not influence the fatigue failure load, number of cycles until fracture and mean survival probabilities of the restorative strategies. Despite that, the mechanical structural reliability of endocrowns, especially those made of lithium disilicate, was higher and lasted more time before start to failing.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Mechanical failure of endocrowns manufactured with different ceramic materials: an in vitro biomechanics study10.1111/jopr.12499 ↗
2. Resin cements formulated with thio-urethanes can strengthen porcelain and increase bond strength to ceramics10.1016/j.jdent.2018.04.002 ↗
3. Fracture strength and stress distribution in premolars restored with cast post-and-cores or glass-fiber posts considering the influence of ferule
4. Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ce-ramic restorations used for endodontically treated teeth10.4012/dmj.2016-017 ↗
5. No post-no core approach to restore severely damaged posterior teeth: an up to 10-year retrospective study of documented endocrown cases10.1016/j.jdent.2017.04.009 ↗
6. Chairside CAD/CAM materials. Part 1:Measurement of elastic constants andmicrostructural characterization10.1016/j.dental.2016.10.009 ↗
7. Comparison of fracture strength of endocrowns and glass fiber post-retained conventional crowns10.2341/11-105-L ↗
8. Clinical evaluation of adhesively placed endo-crowns after two-years preliminary results
9. Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging10.1016/j.prosdent.2017.08.016 ↗
10. In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation10.1016/j.jmbbm.2013.05.004 ↗
11. Damage tolerance of indirect restorative materials (including PICN) after simulated bur adjustments10.1016/j.dental.2015.03.007 ↗
12. Elastic and mechanical properties ofhuman dentin10.1177/00220345580370041801 ↗
13. Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: in vitro and 3-dimensional finite element analysis10.1016/j.joen.2018.04.008 ↗
14. Fractography of a bis-GMA resin10.1177/00220345890680071001 ↗
15. Fracture strength of various types of large direct composite and indirect glass ceramic restorations10.2341/18-111-L ↗
16. A comparison of stresses in molar teeth restored with inlays and direct restorations, including polymerization shrinkage of composite resin and tooth loading during mastication10.1016/j.dental.2014.11.016 ↗
17. The endocrown: a different type of all-ceramic reconstruction for molars
18. Randomized control trial of composite cuspal restorations: five-year results10.1177/0022034513510946 ↗
19. Loading frequencies up to 20 Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic10.1016/j.jmbbm.2016.01.008 ↗
20. Composition and mechanical properties of gutta-percha endodontic points10.1177/00220345750540052901 ↗
21. Microstructural and mechanical characterization of CAD/CAM materials for monolithic dental restorations10.1111/jopr.12964 ↗
22. Greenhalgh · 2009 · 608
23. Effect of endocrown pulp chamber extension depth on molar fracture resistance10.2341/16-097-L ↗
24. Mechanical evaluation of cervical glass-ionomer restorations: 3D finite element study10.1016/j.jdent.2006.04.003 ↗
25. Development of clinically validated bulk failure test for ceramic crowns10.1016/S0022-3913(10)60129-1 ↗
26. ADM guidance-ceramics: fatigue principles and testing10.1016/j.dental.2017.09.006 ↗
27. Effects of thermocycling and occlusal force on adhesive composite crowns10.1177/00220345940730061501 ↗
28. Comparison of the mechanical properties of translucent zirconia and lithium disilicate10.1016/j.prosdent.2017.08.004 ↗
29. Mechanical properties of composite resin blocks for CAD/CAM10.4012/dmj.2014-208 ↗
30. Influence of No-ferrule and No-post buildup design on the fatigue resistance of endodontically treated molars restored with resin nanoceramic CAD/CAM crowns10.2341/13-004-L ↗
31. Three-year clinical evaluation of direct and indirect composite restorations in posterior teeth10.1067/mpr.2000.108774 ↗
32. Biomechanical behavior of teeth without remaining coronal structure restored with different post designs and materials10.1016/j.msec.2017.03.152 ↗
33. Collagen cross-linking and ultimate tensile strength indentin10.1177/154405910408301014 ↗
34. Effect of food simulating liquids on the flexural strength of a methacrylate and silorane-based composite10.1371/journal.pone.0188829 ↗
35. Quantitative study of bite force during sleep associated bruxism10.1046/j.1365-2842.2001.00692.x ↗
36. Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials10.1016/j.jdent.2017.02.007 ↗
37. Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: Fatigue failure load, number of cycles for failure, survival rates, and stress distribution10.1016/j.jmbbm.2018.12.010 ↗
38. The influence of post system design and material on the biomechanical behavior of teeth with little remaining coronal structure10.1111/jopr.12804 ↗
39. How does hydrofluoric acid etching affect the cyclic load-to-failure of lithium disilicate restorations?10.1016/j.jmbbm.2018.07.040 ↗
40. Material properties and fractography of an indirect dental resin composite10.1016/j.dental.2010.02.008 ↗
41. The elastic modulus of dentine determined by static and dynamic methods10.1016/0267-6605(94)90042-6 ↗
42. Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: conventional ceramic etching vs etch & prime one-step primer10.1016/j.dental.2018.04.012 ↗
43. Endocrown restorations: a systematic review and meta-analysis10.1016/j.jdent.2016.07.005 ↗
44. Ceramic strenghtning by tuning the elastic moduli of resin-based luting agentes
45. Maximum bite force analysis in different age groups10.1055/s-0034-1374647 ↗
46. A method for constructing teeth and maxillary bone parametric model from clinical CT scans10.1080/21681163.2014.889579 ↗
47. Fatigue performance of adhesively cemented glass-, hybrid- and resin-ceramic materials for CAD/CAM monolithic restorations10.1016/j.dental.2019.01.013 ↗
48. Effect of the crown, post, and remaining coronal dentin on the biomechanical behavior of endodontically treated maxillary central incisors10.1016/j.prosdent.2013.07.006 ↗
49. Biaxial flexure tests of ceramic substrates
50. Ceramic dental biomaterials and CAD/CAM technology: state of the art
51. Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis10.1016/j.dental.2005.11.034 ↗
52. Fatigue of dental ceramics10.1016/j.jdent.2013.10.007 ↗