journal article·2019-10Open access

Biomechanical assessment of vertebrae with lytic metastases with subject-specific finite element models

M.C. Costa, P. Eltes, A. Lazary, P.P. Varga, M. Viceconti, E. Dall’Ara

Abstract

The assessment of risk of vertebral fracture in patients with lytic metastases is challenging, due to the complexity in modelling the mechanical properties of this heterogeneous material. Currently clinical assessment of patients at high risk of fracture is based on the Spinal Instability Neoplastic Score (SINS), which however in many cases does not provide clear guidelines. The goal of this study was to develop a computational approach to provide a comparative biomechanical assessment of vertebrae with lytic lesions with respect to the adjacent controls and highlight the critical vertebrae. The computed tomography images of the thoracolumbar spine of eight patients suffering of vertebral lytic metastases with SINS between 7 and 12 (indeterminate unstable) were analysed. For each patient one or two vertebrae with lytic lesions were modelled and the closest vertebrae without lesions were considered as control. Metastatic vertebrae (N = 12) and controls (N = 18) were converted to subject-specific, heterogeneous, isotropic, nonlinear finite element models for simulating uniaxial compression. Densitometric and mechanical properties were computed for each vertebra. In average, similar mechanical properties were found for vertebrae with lytic lesions and controls (e.g. ultimate force equal to 6.2 ± 2.7 kN for vertebrae with lytic lesions and to 6.2 ± 3.0 kN for control vertebrae). Only in three patients the vertebrae with lytic lesions were found to be mechanically weaker (-19% to -75% difference for ultimate stress) than the controls. In conclusion, in this study we presented an approach to estimate the mechanical competence of vertebrae with lytic metastases. It remains to be investigated in a clinical study if this method, together with the SINS, can better classify patients with vertebrae with lytic lesions at high risk of fracture.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Management of metastatic bone disease · Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Effect of the metastatic defect on the structural response and failure process of human vertebrae: an experimental study10.1016/j.clinbiomech.2014.10.001 ↗
2. Mechanical assessment of the effects of metastatic lytic defect on the structural response of human thoracolumbar spine10.1002/jor.23154 ↗
3. Female human spines with simulated osteolytic defects: CT-based structural analysis of vertebral body strength10.1148/radiol.2018171139 ↗
4. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
5. Quantitative computed tomography-based predictions of vertebral strength in anterior bending10.1097/01.brs.0000260979.98101.9c ↗
6. Assessment of bone fragility in patients with multiple myeloma using QCT-based finite element modeling10.1002/jbmr.2924 ↗
7. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
8. QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA10.1007/s00198-011-1568-3 ↗
9. Reproducible reference frame for in vitro testing of the human vertebrae10.1016/j.jbiomech.2013.10.005 ↗
10. A biomechanical analysis of metastatic vertebral collapse of the thoracic spine: a sheep model study10.1097/00007632-200405010-00008 ↗
11. Reliability of the Spinal Instability Neoplastic Score ( SINS ) among radiation oncologists : an assessment of instability secondary to spinal metastases10.1186/1748-717X-9-69 ↗
12. Spinal instability neoplastic Score : an analysis of reliability and validity from the spine Oncology study group10.1200/JCO.2010.34.3897 ↗
13. The role of the size and location of the tumors and of the vertebral anatomy in determining the structural stability of the metastatically involved spine: a finite element study10.1016/j.tranon.2018.03.002 ↗
14. Case-specific non-linear finite element models to predict failure behavior in two functional spinal units
15. Quantification of the effect of osteolytic metastases on bone strain within whole vertebrae using image registration10.1002/jor.22045 ↗
16. Digital Volume Correlation for study of the mechanism of whole bones10.1016/j.piutam.2012.05.013 ↗
17. Quantitative, 3-D visualization of the initiation and progression of vertebral fractures under compression and anterior flexion
18. Femoral and vertebral strength improvements in postmenopausa women with osteoporosis treated with denosumab10.1002/jbmr.2024 ↗
19. Lenherr · 2018
20. Estimation of material properties in the equine metacarpus with use of quantitative computed tomography10.1002/jor.1100120610 ↗
21. Strength reductions from trabecular destruction within thoracic vertebrae10.1097/00002517-199304000-00006 ↗
22. Relation of vertebral deformities to bone density ,structure, and strength10.1002/jbmr.150 ↗
23. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
24. Trabecular bone modulus-density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
25. Bone volume fraction explains the variation in strength and stiffness of cancellous bone affected by metastatic cancer and osteoporosis10.1007/s00223-008-9174-x ↗
26. HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models10.1080/10255842.2011.556627 ↗
27. The size of simulated lytic metastases affects the strain distribution on the anterior surface of the vertebra10.1115/1.4040587 ↗
28. Comparison of patient-specific computational models vs. clinical follow-up, for adjacent segment disc degeneration and bone remodelling after spinal fusion10.1371/journal.pone.0200899 ↗
29. A quantitative method for the characterization of lytic metastases of the bone from radiographic images
30. An accurate estimation of bone density improves the accuracy of subject-specific finite element models10.1016/j.jbiomech.2008.05.017 ↗
31. Strength reductions of thoracic vertebrae in the presence of transcortical osseous defects: effects of defect location, pedicle disruption, and defect size10.1007/BF00301407 ↗
32. Stadelmann · 2018
33. A systematic review of evidence on malignant spinal metastases: natural history and technologies for identifying patients at high risk of vertebral fracture and spinal cord compression10.3310/hta17420 ↗
34. Effects of tumor location, shape and surface serration on burst fracture risk in the metastatic spine10.1016/j.jbiomech.2003.09.027 ↗
35. Biomechanics of vertebral level, geometry, and transcortical tumors in the metastatic spine10.1016/j.jbiomech.2005.11.014 ↗
36. Vialle · 2015
37. Prediction of new clinical vertebral fractures in elderly men using finite element analysis of CT scans10.1002/jbmr.1539 ↗
38. Biphasic material properties of lytic bone metastases10.1114/1.1313773 ↗
39. Parametric finite element analysis of vertebral bodies affected by tumors10.1016/S0021-9290(01)00086-0 ↗
40. Burst fracture in the metastatically involved spine: development, validation, and parametric analysis of a three-dimensional poroelastic finite-element model10.1097/01.BRS.0000051910.97211.BA ↗
41. Predicting failure of thoracic vertebrae with simulated and actual metastatic defects
42. Clinical use of quantitative computed tomography-based finite element analysis of the hip and spine int he management of osteoporosis in adults: the 2015 ISCD official positions - Part II10.1016/j.jocd.2015.06.011 ↗