Porous fusion cage is considered as a satisfactory substitute for solid fusion cage in transforaminal lumbar interbody fusion (TLIF) surgery due to its interconnectivity for bone ingrowth and appropriate stiffness reducing the risk of cage subsidence and stress shielding. This study presents an integrated global-local topology optimization approach to obtain porous titanium (Ti) fusion cage with desired biomechanical properties. Local topology optimizations are first conducted to obtain unit cells, and the numerical homogenization method is used to quantified the mechanical properties of unit cells. The preferred porous structure is then fabricated using selective laser melting, and its mechanical property is further verified via compression tests and numerical simulation. Afterward, global topology optimization is used for the global layout. The porous fusion cage obtained by the Boolean intersection between global structural layout and the porous structure decreases the solid volume of the cage by 9% for packing more bone grafts while achieving the same stiffness to conventional porous fusion cage. To eliminate stress concentration in the thin-wall structure, framework structures are constructed on the porous fusion cage. Although the alleviation of cage subsidence and stress shielding is decelerated, peak stress on the cage is significantly decreased, and more even stress distribution is demonstrated in the reinforced porous fusion cage. It promises long-term integrity and functions of the fusion cage. Overall, the reinforced porous fusion cage achieves a favorable mechanical performance and is a promising candidate for fusion surgery. The proposed optimization approach is promising for fusion cage design and can be extended to other orthopedic implant designs.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Additively manufactured metallic porous biomaterials based on minimal surfaces: a unique combination of topological, mechanical, and mass transport properties10.1016/j.actbio.2017.02.024 ↗
2. Mechanical properties and in vitro biological response to porous titanium alloys prepared for use in intervertebral implants10.1016/j.jmbbm.2014.05.029 ↗
3. Interbody spacer material properties and design conformity for reducing subsidence during lumbar interbody fusion10.1115/1.4036312 ↗
4. Stress analysis of the disc adjacent to interbody fusion in lumbar spine10.1016/S1350-4533(01)00076-5 ↗
5. Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: a prospective, randomized, control study with over 7-year follow-up10.1007/s00586-013-2772-y ↗
6. Topology optimisation of spinal interbody cage for reducing stress shielding effect10.1080/10255840903208189 ↗
7. Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc10.1016/j.jbiomech.2004.07.039 ↗
8. Eidel · 2019
9. Osteoinduction of porous Ti implants with a channel structure fabricated by selective laser melting10.1016/j.actbio.2011.01.037 ↗
10. Finite element analysis and design of an interspinous device using topology optimization10.1007/s11517-018-1838-8 ↗
11. Biomechanical evaluation of pedicle screw fixation system in spinal adjacent levels using polyetheretherketone, carbon-fiber-reinforced polyetheretherketone, and traditional titanium as rod materials10.1016/j.compositesb.2017.07.052 ↗
12. The influence of intrinsic disc degeneration of the adjacent segments on its stress distribution after one-level lumbar fusion10.1007/s00586-014-3462-0 ↗
13. Prediction of mechanical behaviors at interfaces between bone and two interbody cages of lumbar spine segments10.1097/00007632-200107010-00010 ↗
14. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
15. Computational comparison of three posterior lumbar interbody fusion techniques by using porous titanium interbody cages with 50% porosity10.1016/j.compbiomed.2016.01.024 ↗
16. Interbody fusion cage design using integrated global layout and local microstructure topology optimization10.1097/01.BRS.0000134573.14150.1A ↗
17. Biomechanical analysis and design of a dynamic spinal fixator using topology optimization: a finite element analysis10.1007/s11517-014-1154-x ↗
18. Biomechanical comparison of multilevel lateral interbody fusion with and without supplementary instrumentation: a three-dimensional finite element study
19. Combination Ti/PEEK ALIF cage for anterior lumbar interbody fusion: early clinical and radiological results10.1016/j.jocn.2016.05.028 ↗
20. Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence10.1016/j.jmbbm.2018.05.040 ↗
21. Bionic mechanical design of titanium bone tissue implants and 3D printing manufacture10.1016/j.matlet.2017.04.128 ↗
22. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis10.1007/s00586-002-0505-8 ↗
23. Osteogenesis of 3D printed porous Ti6Al4V implants with different pore sizes10.1016/j.jmbbm.2018.04.010 ↗
24. Biomechanical effects of implant materials on posterior lumbar interbody fusion: comparison of polyetheretherketone and titanium spacers using finite element analysis and considering bone density10.4236/jbise.2018.114005 ↗
25. Dynamic stabilization of the lumbar spine and its effects on adjacent segments10.1097/00024720-200308000-00015 ↗
26. Designing patient-specific 3D printed craniofacial implants using a novel topology optimization method10.1007/s11517-015-1418-0 ↗
27. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
28. Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion–A finite element study10.1097/01.brs.0000250177.84168.ba ↗
29. The effect of cage stiffness on the rate of lumbar interbody fusion10.1097/00007632-200204010-00003 ↗
30. The effect of 3D-printed Ti6Al4V scaffolds with various macropore structures on osteointegration and osteogenesis: a biomechanical evaluation10.1016/j.jmbbm.2018.08.049 ↗
31. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: a review10.1016/j.biomaterials.2016.01.012 ↗
32. Hip implant design with three-dimensional porous architecture of optimized graded density10.1115/1.4041208 ↗
33. Analysis of factors influencing bone ingrowth into three-dimensional printed porous metal scaffolds: a review10.1016/j.jallcom.2017.05.079 ↗
34. Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models10.1016/S0021-9290(00)00036-1 ↗
35. Topology optimization of microstructure and selective laser melting fabrication for metallic biomaterial scaffolds10.1016/S1003-6326(11)61500-8 ↗
36. Compression–compression fatigue behaviour of gyroid-type triply periodic minimal surface porous structures fabricated by selective laser melting10.1016/j.actamat.2019.09.042 ↗
37. Stress shielding in bone of a bone-cement interface10.1016/j.medengphy.2016.01.009 ↗
38. Biomechanical analysis of porous additive manufactured cages for lateral lumbar interbody fusion: a finite element analysis10.1016/j.wneu.2017.12.127 ↗
39. Finite element model predicts the biomechanical performance of transforaminal lumbar interbody fusion with various porous additive manufactured cages10.1016/j.compbiomed.2018.02.016 ↗
40. Effect of lumbar lordosis on the adjacent segment in transforaminal lumbar interbody fusion: a finite element analysis10.1016/j.wneu.2018.02.073 ↗
41. Finite element analysis of the lumbar spine with a new cage using a topology optimization method10.1016/j.medengphy.2005.03.007 ↗