On the limits of finite element models created from (micro)CT datasets and used in studies of bone-implant-related biomechanical problems
Source abstract
Abstract
Patient-specific approach is gaining a wide popularity in computational simulations of biomechanical systems. Simulations (most often based on the finite element method) are to date routinely created using data from imaging devices such as computed tomography which makes the models seemingly very complex and sophisticated. However, using a computed tomography in finite element calculations does not necessarily enhance the quality or even credibility of the models as these depend on the quality of the input images. Low-resolution (medical-)CT datasets do not always offer detailed representation of trabecular bone in FE models and thus might lead to incorrect calculation of mechanical response to external loading. The effect of image resolution on mechanical simulations of bone-implant interaction has not been thoroughly studied yet. In this study, the effect of image resolution on the modeling procedure and resulting mechanical strains in bone was analyzed on the example of cranial implant. For this purpose, several finite element models of bone interacting with fixation-screws were generated using seven computed tomography datasets of a bone specimen but with different image resolutions (ranging from micro-CT resolution of 25 μm to medical-CT resolution of 1250 μm). The comparative analysis revealed that FE models created from images of low resolution (obtained from medical computed tomography) can produce biased results. There are two main reasons: 1. Medical computed tomography images do not allow generating models with complex trabecular architecture which leads to substituting of the intertrabecular pores with a fictitious mass; 2. Image gray value distribution can be distorted resulting in incorrect mechanical properties of the bone and thus in unrealistic or even completely fictitious mechanical strains. The biased results of calculated mechanical strains can lead to incorrect conclusion, especially when bone-implant interaction is investigated. The image resolution was observed not to significantly affect stresses in the fixation screw itself; however, selection of bone material representation might result in significantly different stresses in the screw.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (63)
Show source-provided references
1. Stress distribution in dental implant with elastomeric stress barrier10.1016/j.matdes.2010.05.053 ↗
2. Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone10.1007/s10237-018-1051-6 ↗
3. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
4. Histologic evaluation of retrieved craniofacial implants. Otolaryngol
5. Parafunctional loading and occlusal device on stress distribution around implants: a 3D finite element analysis10.1016/j.prosdent.2017.12.023 ↗
6. Influence of bone microstructure on the mechanical properties of skull cortical bone – a combined experimental and computational approach10.1016/j.jmbbm.2016.09.041 ↗
7. Robustness in the strategy of scientific model building10.1016/B978-0-12-438150-6.50018-2 ↗
8. Finite element analysis of the human mandible at 3 different stages of life. Oral Surgery10.1016/j.tripleo.2010.01.025 ↗
9. Experimental evaluation of stress distribution with narrow diameter implants: a finite element analysis10.1016/j.prosdent.2017.04.024 ↗
10. Micro Finite Element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
11. Monitoring and interpretation of intracranial pressure10.1136/jnnp.2003.033126 ↗
12. Assessment of trabecular bone tissue elasticity with resonant ultrasound spectroscopy10.1016/j.jmbbm.2017.05.037 ↗
13. Bio-tribology of natural and replacement synovial joints
14. A 2003 update of bone physiology and Wolff's Law for clinicians
15. The influence of mechanical stimulation on osteoclast localization in the mouse maxilla: bone histomorphometry and finite element analysis10.1007/s10237-012-0401-z ↗
16. Inaccuracies in additive manufactured medical skull models caused by the DICOM to STL conversion process10.1016/j.jcms.2013.10.001 ↗
17. Potential for estimation of Young's modulus based on computed tomography numbers in bone: a validation study using a nano-indentation test on murine maxilla10.15761/DOCR.1000254 ↗
18. Static, dynamic and fatigue behaviors of dental implant using finite element method10.1016/j.advengsoft.2006.02.004 ↗
19. Predicting the compressive mechanical behavior of bone10.1016/0021-9290(94)90056-6 ↗
20. The failure envelope concept applied to the bone-dental implant system10.1038/s41598-017-02282-2 ↗
21. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible
22. Patient-specific biomechanical modeling of bone strength using statistically-derived fabric tensors10.1007/s10439-015-1432-2 ↗
23. Trabecular bone strains around a dental implant and associated micromotions—a micro-CT-based three-dimensional finite element study10.1016/j.jbiomech.2010.01.003 ↗
24. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis10.1016/j.jdent.2012.11.008 ↗
25. Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: tissue modulus assignment and sensitivity analyses10.1016/j.jmbbm.2019.03.008 ↗
26. Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone - a feasibility study10.1016/j.jbiomech.2014.10.019 ↗
27. On the level of computational models in biomechanics depending on gained data from CT/MRI and micro-CT
28. Biomechanical performance of cranial implants with different thicknesses and material properties: a finite element study10.1016/j.compbiomed.2019.04.016 ↗
29. Micro finite element analysis of dental implants under different loading conditions10.1016/j.compbiomed.2018.03.012 ↗
30. Micro finite element analysis of dental implants under different loading conditions10.1016/j.compbiomed.2018.03.012 ↗
31. Quantitative comparison of freeware software for bone mesh from DICOM files
32. Experience with cranial implant-based prosthetic reconstruction10.1097/01.scs.0000230614.72141.b9 ↗
33. CT image segmentation of bone for medical additive manufacturing using a convolutional neural network10.1016/j.compbiomed.2018.10.012 ↗
34. The mechanical properties of cranial bone: the effect of loading rate and cranial sampling position10.1016/j.jbiomech.2009.05.030 ↗
35. Finite element analysis of customized reconstruction plates for mandibular continuity defect therapy10.1016/j.jbiomech.2013.11.016 ↗
36. Investigation of bone inelastic response in interaction phenomena with dental implants10.1016/j.dental.2007.11.024 ↗
37. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
38. Pappalardo · 2018
39. Biomechanical analysis of different implant-abutments interfaces in different bone types: an in silico analysis10.1016/j.msec.2018.05.012 ↗
40. Characterization and micromechanical modeling of the human cranial bone elastic properties10.1016/j.mechrescom.2014.04.001 ↗
41. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation10.1016/S0142-9612(97)00073-2 ↗
42. Finite element analysis of 6 large PMMA skull reconstructions: a multi-criteria evaluation approach10.1371/journal.pone.0179325 ↗
43. Structural and mechanical implications of PMMA implant shape and interface geometry in cranioplasty - a finite element study10.1016/j.jcms.2015.10.014 ↗
44. Bone's responses to different designs of implant-supported fixed partial dentures10.1007/s10237-014-0612-6 ↗
45. Finite element analysis suggests functional bone strain accounts for continuous post-eruptive emergence of teeth10.1016/j.archoralbio.2012.05.001 ↗
46. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro10.1016/j.jbiomech.2007.09.009 ↗
47. NIH Image to ImageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
48. Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography10.1016/j.bone.2009.05.023 ↗
49. Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis10.1016/j.bone.2004.11.007 ↗
50. A review of improved fixation methods for dental implants. Part II: biomechanical integrity at bone–implant interface10.1016/j.jpor.2015.01.003 ↗
51. Craniofacial implant surgery
52. Estimation of mechanical properties of cortical bone by computed tomography10.1002/jor.1100090315 ↗
53. A threshold of mechanical strain intensity for the direct activation of osteoblast function exists in a murine maxilla loading model10.1007/s10237-015-0746-1 ↗
54. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques10.1016/S0021-9290(98)00177-8 ↗
55. CT image segmentation methods for bone used in medical additive manufacturing10.1016/j.medengphy.2017.10.008 ↗
56. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
57. Viceconti · 2011
58. Peri-implant stress correlates with bone and cement morphology: micro-FE modeling of implanted cadaveric glenoids10.1002/jor.22933 ↗
59. The discrete nature of trabecular bone microarchitecture affects implant stability10.1016/j.jbiomech.2011.12.024 ↗
60. Finite element analysis of bone loss around failing implants10.1016/j.matdes.2014.04.080 ↗
61. Bone morphological effects on post-implantation remodeling of maxillary anterior buccal bone: a clinical and biomechanical study10.1016/j.jpor.2016.12.010 ↗
62. Physical properties of the human head: mass, center of gravity and moment of inertia10.1016/j.jbiomech.2009.03.029 ↗
63. Patient-specific bone modeling and analysis: the role of integration and automation in clinical adoption10.1016/j.jbiomech.2014.12.018 ↗