journal article·2021-01Open access

Topology optimization of a mandibular reconstruction plate and biomechanical validation

David C. Koper, Carine A.W. Leung, Lars C.P. Smeets, Paul F.J. Laeven, Gabriëlle J.M. Tuijthof, Peter A.W.H. Kessler

Abstract

OBJECTIVES: Reconstruction plates, used to bridge segmental defects of the mandible after tumor resection or traumatic bone tissue loss, are subjected to repeated stresses of mastication. High stress concentrations in these plates can result in hardware failure. Topology optimization (TO) could reduce the peak stress by computing the most optimal material distribution in a patient-specific implant (PSI) used for mandibular reconstruction. The objective of this study was biomechanical validation of a TO-PSI. METHODS: A computer-aided design (CAD) model with a segmental defect was created based on the geometry of a polyurethane mandible model. A standard-PSI was designed to bridge the defect. A TO-PSI was then designed with a maximum stress equal to the ultimate tensile stress of Ti6Al4V (930 MPa) during a loading condition of 378 N. Finite element analysis (FEA) was used to analyze stresses in both PSI designs during loading. The standard-PSI and TO-PSI designs were produced in triplicate by selective laser melting of Ti6Al4V, fixated to polyurethane mandible models with segmental defects identical to the CAD model, and subsequently subjected to continuous compression with a speed of 1 mm/min on a universal testing machine, while recording the load. Peak loads before failure in the TO-PSI group within a 30% range of the predicted peak load (378 N) were considered a successful biomechanical validation. RESULTS: Fracture of the TO-PSI occurred at a median peak load of 334 N (range 304-336 N). These values are within the 30% range of the predicted peak load. Fracture of the mandible model in the standard-PSI group occurred at a median peak load of 1100 N (range 1010-1460 N). Failure locations during biomechanical testing of TO-PSI and standard-PSI samples corresponded to regions in the FEA where stresses exceeded the ultimate tensile strength of titanium and polyurethane, respectively. CONCLUSION: This study demonstrates a successful preliminary biomechanical validation of TO in the design process for mandibular reconstruction plates. Further work is needed to refine the finite element model, which is necessary to ultimately design TO-PSIs for clinical use.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Topology Optimization in Engineering · Facial Trauma and Fracture Management · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Topology optimization and fatigue analysis of temporomandibular joint prosthesis10.4236/wjm.2017.712025 ↗
2. Substitutes for human cadaveric bone in maxillofacial rigid fixation research10.1067/moe.2000.111025 ↗
3. A new classification for mandibular defects after oncological resection10.1016/S1470-2045(15)00310-1 ↗
4. The biomechanical aspects of reconstruction for segmental defects of the mandible: a finite element study to assess the optimisation of plate and screw factors10.1016/j.jcms.2013.12.005 ↗
5. Cienfuegos · 2008
6. Patient-specific reconstruction plates are the missing link in computer-assisted mandibular reconstruction: a showcase for technical description10.1016/j.jcms.2015.02.016 ↗
7. Modeling of jaw biomechanics in the reconstructed mandibulectomy patient10.1016/S0022-3913(99)70244-1 ↗
8. In vitro mechanical analysis of different techniques of internal fixation of combined mandibular angle and body fractures10.1016/j.joms.2015.11.009 ↗
9. A survey of structural and multidisciplinary continuum topology optimization: post 200010.1007/s00158-013-0956-z ↗
10. Plate exposure after anterolateral thigh free-flap reconstruction in head and neck cancer patients with composite mandibular defects10.1245/s10434-014-4322-1 ↗
11. Free flaps in elderly patients: outcomes and complications in head and neck reconstruction after oncological resection10.1016/j.jcms.2012.07.005 ↗
12. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles10.1016/j.joms.2013.06.218 ↗
13. Customized mandibular reconstruction plates improve mechanical performance in a mandibular reconstruction model10.1080/10255842.2016.1240788 ↗
14. Sensitivity analysis for the mechanics of tendons and ligaments: Investigation on the effects of collagen structural properties via a multiscale modeling approach10.1002/cnm.3209 ↗
15. Failure location prediction by finite element analysis for an additive manufactured mandible implant10.1016/j.medengphy.2015.06.001 ↗
16. Mandibular reconstruction using a customized three-dimensional titanium implant applied on the lingual surface of the mandible10.1097/SCS.0000000000004119 ↗
17. Material analysis of AO plate fracture cases10.1016/j.joms.2003.05.009 ↗
18. Development of a functionally equivalent model of the mitral valve chordae tendineae through topology optimization10.1007/s10439-018-02122-y ↗
19. Analysis of mechanical stress in reconstruction plates for bridging mandibular angle defects10.1016/j.jcms.2006.01.004 ↗
20. Study of efficacy and the comparison between 2.0 mm locking plating system and 2.0 mm standard plating system in mandibular fractures10.1007/s12663-014-0718-5 ↗
21. Lemon · 2016
22. Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures10.1016/j.joms.2008.12.032 ↗
23. Biomechanical optimization of bone plates used in rigid fixation of mandibular symphysis fractures10.1016/j.joms.2009.09.108 ↗
24. Fracture of titanium plates used for mandibular reconstruction following ablative tumor surgery10.1002/jbm.b.30603 ↗
25. Masticatory function in hemimandibulectomy patients10.1111/j.1365-2842.1992.tb01104.x ↗
26. Materialise · 2020
27. De novo topology optimization of total ossicular replacement prostheses10.1016/j.jmbbm.2019.103541 ↗
28. Biomechanics of occlusion--implications for oral rehabilitation10.1111/joor.12345 ↗
29. Use of a three-dimensional custom-made porous titanium prosthesis for mandibular body reconstruction10.1016/j.ijom.2017.06.001 ↗
30. Porous architected biomaterial for a tibial-knee implant with minimum bone resorption and bone-implant interface micromotion10.1016/j.jmbbm.2017.11.041 ↗
31. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: a biomechanical in vitro analysis10.1016/j.jcms.2017.08.024 ↗
32. Free flap surgery in Europe: an interdisciplinary survey10.1016/j.ijom.2017.11.013 ↗
33. Patient specific glass fiber reinforced composite versus titanium plate: a comparative biomechanical analysis under cyclic dynamic loading10.1016/j.jmbbm.2018.12.014 ↗
34. Accuracy of secondary maxillofacial reconstruction with prefabricated fibula grafts using 3D planning and guided reconstruction10.1016/j.jcms.2015.12.008 ↗
35. Biomechanical testing of different osteosynthesis systems for segmental resection of the mandible10.1016/j.joms.2006.06.306 ↗
36. Variations in cortical material properties throughout the human dentate mandible10.1002/ajpa.10121 ↗
37. Seebach M, Theurer F, Foehr P, Deimling Cv, Burgkart R, Zaeh MF, editors. Design of Bone Plates for Mandibular Reconstruction Using Topology and Shape Optimization2018; Cham: Springer International Publishing.10.1007/978-3-319-67988-4_154 ↗
38. Fracture of mandibular reconstruction plates used after tumor resection10.1053/joms.2002.29817 ↗
39. Implant failure caused by screw head fractures--a new type of complication in a reconstruction plate: a case report10.1053/joms.2000.8221 ↗
40. Topology optimization: a tool for the tailoring of structures and materials10.1098/rsta.2000.0528 ↗
41. Swierstra · 2017
42. Finite element analysis: a boon to dentistry10.1016/j.jobcr.2014.11.008 ↗
43. Analysis of reconstruction of mandibular defects using single stainless steel A-O reconstruction plates10.1016/S0278-2391(96)90536-4 ↗
44. Deriving tissue density and elastic modulus from microCT bone scans10.1016/j.bone.2011.07.021 ↗
45. Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction10.1007/s11548-015-1193-2 ↗
46. Biomechanics of mandibular reconstruction: a review10.1016/j.ijom.2009.11.003 ↗
47. Biomechanical evaluation of a novel hybrid reconstruction plate for mandible segmental defects: a finite element analysis and fatigue testing10.1016/j.jcms.2017.07.010 ↗
48. Advanced biomaterials for repairing and reconstruction of mandibular defects10.1016/j.msec.2019.109858 ↗
49. Topology optimization in aircraft and aerospace structures design10.1007/s11831-015-9151-2 ↗
50. Biomechanical comparison of a multidirectional locking plate and conventional plates for the osteosynthesis of mandibular angle fractures-A preliminary study10.1016/j.jcms.2017.05.020 ↗