Development and validation of a finite-element musculoskeletal model incorporating a deformable contact model of the hip joint during gait
Source abstract
Abstract
Musculoskeletal models provide non-invasive and subject-specific biomechanical investigations of the musculoskeletal system. In a musculoskeletal model, muscle forces contribute to the deformation and kinematics of the joint which in turn would alter moment arms of muscles and ground reaction forces and thus affect the prediction of muscle forces and contact forces and contact mechanics of the joint. By far, deformable contact models of the hip have not been considered in musculoskeletal models, and the role of kinematics and deformation within the hip in muscle forces and hip contact mechanics is unknown. In this study, an FE musculoskeletal model including bones, joints and muscles of the lower extremity was developed. A deformable contact model of the hip joint was incorporated and coupled into the musculoskeletal model. Joint angles and ground reaction forces during gait were used as inputs. Optimization minimizing the sum of muscle stresses squared was performed directly to the FE musculoskeletal model in order to simultaneously solve muscle forces and contact forces and contact stresses of the hip joint within a single framework. The calculated hip contact forces corresponded well to the in vivo measurement data. The maximum hip contact stress was 6.5 MPa and occurred at weight-acceptance. The influence of kinematics and deformation in the hip on muscles forces and hip contact forces was minimal and not sensitive to variations in the thickness and properties of the joint cartilage during gait. This suggests that the uncoupled approach in which the hip contact forces and contact mechanics are simulated in separate frameworks would serve as an effective and efficient alternative for subject-specific modelling of the hip. This study provides guidance for the level of complexity needed for future hip models and can be used to evaluate biomechanical changes of the musculoskeletal system following interventions.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Muscle activation and electromyography studies · Hip disorders and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Consideration of equilibrium equations at the hip joint alongside those at the knee and ankle joints has mixed effects on knee joint response during gait10.1016/j.jbiomech.2012.09.035 ↗
2. Contact pressures in the human hip joint10.1302/0301-620X.69B4.3611154 ↗
3. Validation of finite element predictions of cartilage contact pressure in the human hip joint10.1115/1.2953472 ↗
4. Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilage10.1002/jor.1100120306 ↗
5. Standardized loads acting in hip implants10.1371/journal.pone.0155612 ↗
6. In vitro contact stress distributions in the natural human hip10.1016/0021-9290(83)90071-4 ↗
7. TLEM 2.0 – a comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity10.1016/j.jbiomech.2014.12.034 ↗
8. Refining muscle geometry and wrapping in the TLEM 2 model for improved hip contact force prediction10.1371/journal.pone.0204109 ↗
9. OpenSim: open-source software to create and analyze dynamic simulations of movement10.1109/TBME.2007.901024 ↗
10. Individuals with patellofemoral pain exhibit greater patellofemoral joint stress: a finite element analysis study10.1016/j.joca.2010.12.001 ↗
11. Finite element prediction of transchondral stress and strain in the human hip10.1115/1.4026101 ↗
12. Role of the acetabular labrum in load support across the hip joint10.1016/j.jbiomech.2011.06.011 ↗
13. A lower extremity model for muscle-driven simulation of activity using explicit finite element modeling10.1016/j.jbiomech.2018.12.040 ↗
14. The normal hip joint space: variations in width, shape, and architecture on 223 pelvic radiographs10.1136/ard.2003.018424 ↗
15. The influence of the representation of collagen fibre organisation on the cartilage contact mechanics of the hip joint10.1016/j.jbiomech.2016.03.050 ↗
16. Development of a finite element musculoskeletal model with the ability to predict contractions of three-dimensional muscles10.1016/j.jbiomech.2019.07.042 ↗
17. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking10.1016/j.clinbiomech.2015.02.014 ↗
18. The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers10.1016/j.jbiomech.2013.04.009 ↗
19. Experimental validation of a new biphasic model of the contact mechanics of the porcine hip10.1177/0954411914537618 ↗
20. Maas
21. 3D active-passive response of human knee joint in gait is markedly altered when simulated as a planar 2D joint10.1007/s10237-016-0846-6 ↗
22. Sensitivity of the knee joint response, muscle forces and stability to variations in gait kinematics-kinetics10.1016/j.jbiomech.2019.109472 ↗
23. Thickness of human articular cartilage in joints of the lower limb10.1136/ard.58.1.27 ↗
24. A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement10.1016/j.jbiomech.2018.07.008 ↗
25. Hip chondrolabral mechanics during activities of daily living: role of the labrum and interstitial fluid pressurization10.1016/j.jbiomech.2018.01.001 ↗
26. Prediction of hip joint load and translation using musculoskeletal modelling with force-dependent kinematics and experimental validation10.1177/0954411915589115 ↗