journal article·2022-09Open access

A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography

E. Dall’Ara, A.J. Bodey, H. Isaksson, G. Tozzi

Abstract

Musculoskeletal tissues are complex hierarchical materials where mechanical response is linked to structural and material properties at different dimensional levels. Therefore, high-resolution three-dimensional tomography is very useful for assessing tissue properties at different scales. In particular, Synchrotron Radiation micro-Computed Tomography (SR-microCT) has been used in several applications to analyze the structure of bone and biomaterials. In the past decade the development of digital volume correlation (DVC) algorithms applied to SR-microCT images and its combination with in situ mechanical testing (four-dimensional imaging) have allowed researchers to visualise, for the first time, the deformation of musculoskeletal tissues and their interaction with biomaterials under different loading scenarios. However, there are several experimental challenges that make these measurements difficult and at high risk of failure. Challenges relate to sample preparation, imaging parameters, loading setup, accumulated tissue damage for multiple tomographic acquisitions, reconstruction methods and data processing. Considering that access to SR-microCT facilities is usually associated with bidding processes and long waiting times, the failure of these experiments could notably slow down the advancement of this research area and reduce its impact. Many of the experimental failures can be avoided with increased experience in performing the tests and better guidelines for preparation and execution of these complex experiments; publication of negative results could help interested researchers to avoid recurring mistakes. Therefore, the goal of this article is to highlight the potential and pitfalls in the design and execution of in situ SR-microCT experiments, involving multiple scans, of musculoskeletal tissues for the assessment of their structural and/or mechanical properties. The advice and guidelines that follow should improve the success rate of this type of experiment, allowing the community to reach higher impact more efficiently.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (91)

Show source-provided references
1. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source
2. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone10.1016/j.bone.2010.02.025 ↗
3. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
4. Data analysis WorkbeNch (DAWN)10.1107/S1600577515002283 ↗
5. Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone10.1002/jor.1100130214 ↗
6. Three-dimensional morphometry of strained bovine periodontal ligament using synchrotron radiation-based tomography10.1111/j.1469-7580.2010.01250.x ↗
7. Launch of the I13-2 data beamline at the Diamond light source synchrotron10.1088/1742-6596/849/1/012038 ↗
8. Glenoid bone strain after anatomical total shoulder arthroplasty: in vitro measurements with micro-CT and digital volume correlation10.1016/j.medengphy.2020.09.009 ↗
9. Mechanical and structural characterisation of completely degradable polylactic acid/calcium phosphate glass scaffolds10.1016/j.biomaterials.2007.06.029 ↗
10. Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study10.1016/j.jmbbm.2016.09.014 ↗
11. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
12. Exploratory full-field mechanical analysis across the osteochondral tissue-biomaterial interface in an ovine model10.3390/ma13183911 ↗
13. High resolution three-dimensional strain measurements in human articular cartilage10.1016/j.jmbbm.2021.104806 ↗
14. Characterization of osteoarthritic and normal human patella cartilage by computed tomography X-ray phase-contrast imaging: a feasibility study10.1097/RLI.0b013e3181e193bd ↗
15. Uncertainties of synchrotron microCT-based digital volume correlation bone strain measurements under simulated deformation10.1016/j.jbiomech.2019.01.041 ↗
16. Micro Finite Element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
17. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
18. A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro10.1016/j.bone.2012.09.006 ↗
19. Precision of digital volume correlation approaches for strain analysis in bone imaged with micro-computed tomography at different dimensional levels
20. Application of digital volume correlation to study the efficacy of prophylactic vertebral augmentation10.1016/j.clinbiomech.2016.07.010 ↗
21. Innovations in laboratory-based dynamic micro-CT to accelerate in situ research10.1111/jmi.12879 ↗
22. Analysis of sintered polymer scaffolds using concomitant synchrotron computed tomography and in situ mechanical testing10.1007/s10856-011-4443-z ↗
23. Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns10.1016/j.actbio.2019.05.021 ↗
24. Visualising the 3D microstructure of stained and native intervertebral discs using X-ray microtomography10.1038/s41598-017-16354-w ↗
25. The degradation properties of co-continuous calcium phosphate polyester composites: insights with synchrotron micro-computer tomography
26. Three-dimensional visualization of bioactive glass-bone integration in a rabbit tibia model using synchrotron X-ray microcomputed tomography10.1089/ten.tea.2011.0068 ↗
27. Extracting accurate strain measurements in bone mechanics: a critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
28. Synchrotron MicroCT reveals the potential of the dual contrast technique for quantitative assessment of human articular cartilage composition10.1002/jor.24479 ↗
29. Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation10.1186/s12929-021-00739-1 ↗
30. Experimental validation of finite element analysis of human vertebral collapse under large compressive strains10.1115/1.4026409 ↗
31. Differences in trabecular microarchitecture and simplified boundary conditions limit the accuracy of quantitative computed tomography-based finite element models of vertebral failure10.1115/1.4038609 ↗
32. Quantitative, 3D visualization of the initiation and progression of vertebral fractures under compression and anterior flexion10.1002/jbmr.2749 ↗
33. Functional adaptation of interradicular alveolar bone to reduced chewing loads on dentoalveolar joints in rats10.1016/j.dental.2020.12.003 ↗
34. Trabecular deformations during screw pull-out: a micro-CT study of lapine bone10.1007/s10237-017-0891-9 ↗
35. Full-field strain of regenerated bone tissue in a femoral fracture model10.1111/jmi.12937 ↗
36. Micromechanical evaluation of cortical bone using in situ XCT indentation and digital volume correlation10.1016/j.jmbbm.2020.104298 ↗
37. Material mapping of QCT-derived scapular models: a comparison with micro-CT loaded specimens using digital volume correlation10.1007/s10439-019-02312-2 ↗
38. Fracture behavior of a composite of bone and calcium sulfate/hydroxyapatite10.1016/j.jmbbm.2022.105201 ↗
39. 3D X-ray ultra-microscopy of bone tissue10.1007/s00198-015-3257-0 ↗
40. Bone damage evolution around integrated metal screws using X-ray tomography - in situ pullout and digital volume correlation10.3389/fbioe.2020.00934 ↗
41. Investigating the mechanical characteristics of bone-metal implant interface using in situ synchrotron tomographic imaging10.3389/fbioe.2018.00208 ↗
42. Biomechanics of a bone-periodontal ligament-tooth fibrous joint10.1016/j.jbiomech.2012.11.010 ↗
43. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
44. Dose optimization approach to fast X-ray microtomography of the lung alveoli10.1107/S0021889813005591 ↗
45. Anisotropic crack propagation and deformation in dentin observed by four-dimensional X-ray nano-computed tomography10.1016/j.actbio.2019.06.042 ↗
46. Long-term effects of bisphosphonate therapy: perforations, microcracks and mechanical properties
47. In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography10.1038/s41551-019-0477-1 ↗
48. Damage tolerance and toughness of elderly human femora10.1016/j.actbio.2021.01.011 ↗
49. Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture10.1016/j.jmbbm.2018.05.016 ↗
50. Synchrotron radiation techniques boost the research in bone tissue engineering10.1016/j.actbio.2019.03.031 ↗
51. Phase contrast imaging X-ray computed tomography: quantitative characterization of human patellar cartilage matrix with topological and geometrical features
52. A noninvasive MRI based approach to estimate the mechanical properties of human knee ligaments10.1016/j.jmbbm.2019.01.022 ↗
53. Tooth periodontal ligament: direct 3D microCT visualization of the collagen network and how the network changes when the tooth is loaded10.1016/j.jsb.2012.10.008 ↗
54. Design and implementation of a novel mechanical testing system for cellular solids10.1002/jbm.b.30232 ↗
55. Quantitative and qualitative bone imaging: a review of synchrotron radiation microtomography analysis in bone research10.1016/j.jmbbm.2020.103887 ↗
56. Validation of finite element models of the mouse tibia using digital volume correlation10.1016/j.jmbbm.2018.06.022 ↗
57. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
58. Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation10.1016/j.jmbbm.2018.08.012 ↗
59. Full-field strain analysis of bone-biomaterial systems produced by the implantation of osteoregenerative biomaterials in an ovine model10.1021/acsbiomaterials.8b01044 ↗
60. Preservation of bone tissue integrity with temperature control for in situ SR-MicroCT experiments10.3390/ma11112155 ↗
61. Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation10.1016/j.actbio.2021.06.014 ↗
62. Synchrotron radiation microCT: a reference tool for the characterization of bone samples10.1007/978-1-4615-0651-5_14 ↗
63. Muscular loading affects the 3D structure of both the mineralized rudiment and growth plate at early stages of bone formation10.1016/j.bone.2021.115849 ↗
64. A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography10.1038/s41598-021-96589-w ↗
65. Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation10.1016/j.jmbbm.2019.04.054 ↗
66. Femoral fracture type can be predicted from femoral structure: a finite element study validated by digital volume correlation experiments10.1002/jor.23669 ↗
67. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
68. Heterogeneous strain distribution in the subchondral bone of human osteoarthritic femoral heads, measured with digital volume correlation10.3390/ma13204619 ↗
69. A synchrotron radiation microtomography system for the analysis of trabecular bone samples10.1118/1.598736 ↗
70. X-ray computed tomography of the anterior cruciate ligament and patellar tendon10.32098/mltj.02.2014.26 ↗
71. Optimising complementary soft tissue synchrotron X-ray microtomography for reversibly-stained central nervous system samples10.1038/s41598-018-30520-8 ↗
72. Quantifying deformations and strains in human intervertebral discs using Digital Volume Correlation combined with MRI (DVC-MRI)10.1016/j.jbiomech.2020.109604 ↗
73. The effect of degeneration on internal strains and the mechanism of failure in human intervertebral discs analyzed using digital volume correlation (DVC) and ultra-high field MRI
74. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light10.1016/j.bone.2006.01.147 ↗
75. A priori information in a regularized sinogram-based method for removing ring artefacts in tomography10.1107/S0909049510010964 ↗
76. Full-field strain uncertainties and residuals at the cartilage-bone interface in unstained tissues using propagation-based phase-contrast XCT and digital volume correlation10.3390/ma13112579 ↗
77. Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression10.1016/j.jbiomech.2014.09.012 ↗
78. Sub-trabecular strain evolution in human trabecular bone10.1038/s41598-020-69850-x ↗
79. Radial lens distortion correction with sub-pixel accuracy for X-ray micro-tomography10.1364/OE.23.032859 ↗
80. Superior techniques for eliminating ring artifacts in X-ray micro-tomography10.1364/OE.26.028396 ↗
81. Time-lapsed assessment of microcrack initiation and propagation in murine cortical bone at submicrometer resolution10.1016/j.bone.2009.04.248 ↗
82. Wadeson · 2016
83. Synchrotron X-ray microtomography (on a micron scale) provides three-dimensional imaging representation of bone ingrowth in calcium phosphate biomaterials10.1016/S0142-9612(03)00335-1 ↗
84. A method for fracture toughness measurement in trabecular bone using computed tomography, image correlation and finite element methods10.1016/j.jmbbm.2020.103838 ↗
85. Assessment of the human bone lacuno-canalicular network at the nanoscale and impact of spatial resolution10.1038/s41598-020-61269-8 ↗
86. Synchrotron X-ray microtomography for assessment of bone tissue scaffolds10.1007/s10856-009-3888-9 ↗
87. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements10.1115/1.2146001 ↗
88. Standardizing compression testing for measuring the stiffness of human bone10.1302/2046-3758.78.BJR-2018-0025.R1 ↗
89. Three-dimensional characterization of the microstructure in rabbit patella-patellar tendon interface using propagation phase-contrast synchrotron radiation microtomography10.1107/S160057751801353X ↗
90. Age-related changes in the plasticity and toughness of human cortical bone at multiple length scales10.1073/pnas.1107966108 ↗
91. Inverse finite element modeling for characterization of local elastic properties in image-guided failure assessment of human trabecular bone10.1115/1.4028991 ↗