The mechanics of head-neck taper junctions: What do we know from finite element analysis?
Source abstract
Abstract
Modular hip implants are widely used in hip arthroplasty because of the advantages they can offer such as flexibility in material combinations and geometrical adjustments. The mechanical environment of the modular junction in the body is quite challenging due to the complex and varying off-axial mechanical loads of physical activities applied to a tapered interface of two contacting materials (head and neck) assembled by an impact force intraoperatively. Experimental analogies to the in-vivo condition of the taper junction are complex, expensive and time-consuming to implement; hence, computational simulations have been a preferred approach taken by researchers for studying the mechanics of these modular junctions that can help us understand their failure mechanisms and improve their design and longevity after implantation. This paper provides a clearer insight into the mechanics of the head-neck taper junction through a careful review on the finite element studies of the junction and their findings. The effects of various factors on the mechanical outputs namely: stresses, micromotions, and contact situations are reviewed and discussed. Also, the simulation methodology of the studies in the literature is compared. Research opportunities for future are scrutinised through tabulating data and information that have been carefully retrieved form the reported findings.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. Optimization of the stress distribution in ceramic femoral heads by means of finite element methods10.1243/09544119JEIM429 ↗
2. Axisymmetric mechanical analysis of ceramic heads for total hip replacement10.1243/PIME_PROC_1990_204_250_02 ↗
3. Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation10.1016/j.jbiomech.2017.07.027 ↗
4. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
5. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections10.1016/j.medengphy.2012.07.013 ↗
6. A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement10.1177/0954411917713774 ↗
7. Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants10.1016/j.jmbbm.2017.10.032 ↗
8. The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty10.1080/10255842.2019.1627524 ↗
9. Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system10.1002/jor.22970 ↗
10. Stress and micromotion in the taper lock joint of a modular segmental bone replacement prosthesis10.1016/S0021-9290(00)00058-0 ↗
11. Wear and corrosion of modular interfaces in total hip replacements
12. Impaction force influences taper-trunnion stability in total hip arthroplasty10.1016/j.arth.2018.01.020 ↗
13. Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters10.1016/j.jbiomech.2014.02.035 ↗
14. Finite element analysis of the head-neck taper interface of modular hip prostheses10.1016/j.triboint.2015.01.016 ↗
15. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis10.1007/s11999-013-3244-8 ↗
16. A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
17. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
18. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors
19. Adapter sleeves are essential for ceramic heads in hip revision surgery10.1016/j.clinbiomech.2019.10.018 ↗
20. Influence of geometry and materials on the axial and torsional strength of the head-neck taper junction in modular hip replacements: a finite element study10.1016/j.jmbbm.2015.12.044 ↗
21. Fallahnezhad · 2017
22. An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: the role of taper angle mismatch10.1016/j.jmbbm.2017.07.003 ↗
23. A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 210.1016/j.jmbbm.2017.08.038 ↗
24. The influence of assembly force on the material loss at the metallic head-neck junction of hip implants subjected to cyclic fretting wear10.3390/met9040422 ↗
25. A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 1, level walking10.1016/j.jmbbm.2017.08.012 ↗
26. CORR insights(A (R)): does surface topography play a role in taper damage in head-neck modular junctions?10.1007/s11999-016-4973-2 ↗
27. Influence of assembly force and distraction on the femoral head-taper junction10.1016/j.arth.2018.02.030 ↗
28. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements10.1002/jbm.b.33972 ↗
29. Influence of flexural rigidity on micromotion at the head-stem taper interface of modular hip prostheses10.1016/j.medengphy.2019.03.020 ↗
30. Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty10.1007/s00402-008-0660-4 ↗
31. One hundred and fifty years of history of the Morse taper: from Stephen A. Morse in 1864 to complications related to modularity in hip arthroplasty10.1007/s00264-013-1927-0 ↗
32. Huebner · 2001
33. Head-neck taper corrosion in hip arthroplasty10.1155/2015/758123 ↗
34. Wear reduction in modular taper-trunnion hip prostheses using straight cylindrical stems
35. Determination of the pullout/holding strength at the taper-trunnion junction of hip implants
36. 2003
37. Effect of trunnion roughness and length on the modular taper junction strength under typical intraoperative assembly forces10.1016/j.medengphy.2016.11.001 ↗
38. Research on the torsional fretting behavior of the head–neck interface of artificial hip joint10.1016/j.matdes.2013.12.007 ↗
39. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement10.1016/j.medengphy.2006.07.001 ↗
40. Proximal component modularity in THA—at what cost?: an implant retrieval study10.1007/s11999-011-2155-9 ↗
41. The influence of contamination and cleaning on the strength of modular head taper fixation in total hip arthroplasty10.1016/j.arth.2017.05.009 ↗
42. Accelerating failure rate of the ASR total hip replacement
43. Effect of geometric parameters in the design of hip implants paper IV10.1016/j.matdes.2004.01.012 ↗
44. Trunnion-head stresses in THA: are big heads trouble?10.1016/j.arth.2015.01.021 ↗
45. Effect of neck length on third-generation ceramic head failure; finite element and retrieval analysis10.1007/s00776-014-0573-8 ↗
46. An analysis of the head-neck taper interface in retrieved hip prostheses
47. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability10.1302/2046-3758.58.BJR-2016-0044.R1 ↗
48. Investigations into the mechanical reliability of ceramic femoral heads for hip joints10.1007/BF00058992 ↗
49. Trunnionosis in total hip arthroplasty: a review10.1007/s10195-016-0391-1 ↗
50. Head taper corrosion causing head bottoming out and consecutive gross stem taper failure in total hip arthroplasty10.1016/j.arth.2018.07.017 ↗
51. Taper-trunnion interface stress varies significantly with head size and activity10.1016/j.arth.2018.09.004 ↗
52. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography10.1002/jor.22461 ↗
53. Morse-type tapers - factors that may influence taper strength during total hip arthroplasty10.1054/arth.2002.33565 ↗
54. Prediction of taper performance using quasi static FE models: the influence of loading, taper clearance and trunnion length10.1002/jbm.b.34104 ↗
55. Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses10.1016/j.clinbiomech.2011.08.002 ↗
56. Effect of manufacturing tolerances on the micromotion at the Morse taper interface in modular hip implants using the finite element technique10.1016/0142-9612(96)88713-8 ↗
57. Does taper design affect taper fretting corrosion in ceramic-on-polyethylene total hip arthroplasty? A retrieval analysis10.1016/j.arth.2019.02.058 ↗
58. Mechanical stability of the taper connection of large metal femoral heads with adapter sleeves in total hip arthroplasty analyzed using explicit finite element simulations10.1016/j.arth.2017.03.033 ↗
59. Evidence based recommendations for reducing head-neck taper connection fretting corrosion in hip replacement prostheses10.5301/hipint.5000545 ↗
60. Quantification of the contact area at the head-stem taper interface of modular hip prostheses10.1371/journal.pone.0135517 ↗
61. DPhil (oxon), Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty
62. Taper fretting behavior of PEEK artificial hip joint10.1016/j.triboint.2019.04.027 ↗
63. A finite element methodology for wear–fatigue analysis for modular hip implants10.1016/j.triboint.2013.02.016 ↗
64. Micro–macro wear–fatigue of modular hip implant taper-lock coupling10.1177/0309324713502175 ↗