journal article·2022-04

Blood clot behaves as a poro-visco-elastic material

Farshid Ghezelbash, Shiyu Liu, Aboulfazl Shirazi-Adl, Jianyu Li

Publisher page

Abstract

Mechanical properties of blood clots play a crucial role in hemostasis and embolization. They are time-dependent and often described with viscoelastic models. But blood clots also exhibit some hallmark features of poroelasticity, as most biological tissues exhibit concurrent viscoelasticity and poroelasticity. In this study, we characterized the time-dependent behavior of blood clots, and developed an experimental-computational framework to decouple and model poroelastic and viscoelastic responses. Compression stress relaxation tests were conducted on bovine blood clots with different diameters to evaluate the influence of sample size on the relaxation time. In the compression tests, the mass of blood clots was measured to estimate fluid migration. To capture pure viscoelastic responses, rheological shear stress relaxation tests were carried out. A poroviscoelastic model was also proposed and calibrated to capture the complex multiaxial (compression and shear) relaxation behavior of blood clots. In unconfined compression tests, stresses relaxed markedly (average: 83%; range: 76-90%), and samples with larger diameters showed longer relaxation time. Blood clots lost about 24% of their initial masses, and the mass transport took place gradually in compression tests. Under shear deformation, blood clots relaxed in average 37% (range: 32-39%) which was much less than those under unconfined compression tests (in average 37% versus 83%). Unlike poroelastic and viscoelastic theories, the poroviscoelastic model accurately predicted multiaxial responses of blood clots under compression and shear; additionally, the estimated Darcy's coefficient (4.4×10-9 cm2) was found within the reported physiological range (0.1×10-9 to 36 × 10-9 cm2). The combination of size-dependent stress relaxation and mass loss under compression (due to poroelasticity) as well as substantial stress relaxation under shear deformation (due to viscoelasticity) demonstrate that blood clot behaves as a poroviscoelastic material; therefore, accurate interpretation of transient responses of blood clots requires a validated poroviscoelastic model. This work provides understanding and methodology on blood clot mechanics and will further motivate the development of clot-like biomaterials.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Blood properties and coagulation · Rheology and Fluid Dynamics Studies · Elasticity and Material Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Abaqus · 2019 · vol. 651
2. Marked increase of fibrin gel permeability with very low dose ASA treatment10.1016/j.thromres.2005.02.007 ↗
3. Equivalence between short-time biphasic and incompressible elastic material responses10.1115/1.2720918 ↗
4. Fibrin gel structure and clotting time10.1016/0049-3848(82)90214-6 ↗
5. Large strain viscoelastic constitutive models10.1016/S0020-7683(00)00215-8 ↗
6. Multiscale mechanics of fibrin polymer: gel stretching with protein unfolding and loss of water10.1126/science.1172484 ↗
7. Spherical indentation testing of poroelastic relaxations in thin hydrogel layers10.1039/C1SM06514A ↗
8. Effects of extracellular matrix viscoelasticity on cellular behaviour10.1038/s41586-020-2612-2 ↗
9. Unconfined compression of white matter10.1016/j.jbiomech.2005.11.004 ↗
10. Fibrin clots are equilibrium polymers that can be remodeled without proteolytic digestion10.1038/srep00879 ↗
11. Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs10.3174/ajnr.A2485 ↗
12. Coussy · 2004
13. Constitutive modeling of brain tissue: current perspectives10.1115/1.4032436 ↗
14. Simple shear is not so simple10.1016/j.ijnonlinmec.2011.05.008 ↗
15. Fibrin clot permeability as a predictor of stroke and bleeding in anticoagulated patients with atrial fibrillation10.1161/STROKEAHA.117.018143 ↗
16. Troubleshooting in platelet storage temperature and new perspectives through proteomics
17. Fereidoonnezhad · 2021
18. Clinical outcomes and plasma clot permeability and lysability in patients with venous thromboembolism on rivaroxaban: a cohort study
19. Fibrin network structure and clot mechanical properties are altered by incorporation of erythrocytes10.1160/TH09-03-0199 ↗
20. Rheology of fibrin clots II: linear viscoelastic behavior in shear creep10.1016/0301-4622(74)80046-3 ↗
21. Modeling of human intervertebral disc annulus fibrosus with complex multi-fiber networks10.1016/j.actbio.2020.12.062 ↗
22. On the modeling of human intervertebral disc annulus fibrosus: elastic, permanent deformation and failure responses10.1016/j.jbiomech.2019.109463 ↗
23. Holzapfel · 2000
24. Viscoelasticity and poroelasticity in elastomeric gels10.1016/S0894-9166(12)60039-1 ↗
25. Using indentation to characterize the poroelasticity of gels10.1063/1.3370354 ↗
26. Rheology of fibrin clots. VI. Stress relaxation, creep, and differential dynamic modulus of fine clots in large shearing deformations10.1122/1.549722 ↗
27. Investigating the mechanical behavior of clot analogues through experimental and computational analysis10.1007/s10439-020-02570-5 ↗
28. Platelet storage temperature–how low can we go?10.1159/000103920 ↗
29. Dynamic viscoelastic study for the structure of fibrin networks in the clots of blood and plasma
30. Foam-like compression behavior of fibrin networks10.1007/s10237-015-0683-z ↗
31. Structural basis for the nonlinear mechanics of fibrin networks under compression10.1016/j.biomaterials.2014.04.056 ↗
32. A special theory of biphasic mixtures and experimental results for human annulus fibrosus tested in confined compression10.1115/1.429640 ↗
33. A transversely isotropic viscohyperelastic material: application to the modeling of biological soft connective tissues10.1016/j.ijsolstr.2004.02.057 ↗
34. Fibrin mechanical properties and their structural origins10.1016/j.matbio.2016.08.003 ↗
35. Anisotropic finite strain viscoelasticity: constitutive modeling and finite element implementation10.1016/j.jmps.2018.09.014 ↗
36. Fracture mechanics of blood clots: measurements of toughness and critical length scales10.1016/j.eml.2021.101444 ↗
37. The mechanical properties of single fibrin fibers10.1111/j.1538-7836.2010.03745.x ↗
38. Effect of structural distortions on articular cartilage permeability under large deformations10.1007/s10237-019-01213-6 ↗
39. Haemostatic changes related to fibrin formation and fibrinolysis during the first trimester in normal pregnancy and in recurrent miscarriage10.1160/TH06-09-0542 ↗
40. The cytoplasm of living cells behaves as a poroelastic material10.1038/nmat3517 ↗
41. Blood rheology: key parameters, impact on blood flow, role in sickle cell disease and effects of exercise10.3389/fphys.2019.01329 ↗
42. Thrombin flux and wall shear rate regulate fibrin fiber deposition state during polymerization under flow10.1016/j.bpj.2009.12.4275 ↗
43. Niessen · 2003 · vol. 34 · 2019
44. Pathare · 2021
45. An international study on the standardization of fibrin clot permeability measurement: methodological considerations and implications for healthy control values10.1111/j.1538-7836.2012.04883.x ↗
46. Viscoelasticity of the human red blood cell10.1152/ajpcell.00562.2006 ↗
47. Hyper-viscoelastic damage modeling of whole blood clot under large deformation
48. Analysis of articular cartilage as a composite using nonlinear membrane elements for collagen fibrils10.1016/j.medengphy.2005.04.024 ↗
49. Preparation and mounting of whole blood clot samples for mechanical testing10.1002/cpz1.197 ↗
50. A whole blood thrombus mimic: constitutive behavior under simple shear10.1016/j.jmbbm.2020.104216 ↗
51. Nonlinear, dissipative phenomena in whole blood clot mechanics10.1039/D0SM01317J ↗
52. Interplay of platelet contractility and elasticity of fibrin/erythrocytes in blood clot retraction10.1016/j.bpj.2017.01.005 ↗
53. Fibrin clot properties are altered in patients with chronic obstructive pulmonary disease10.1160/TH09-02-0118 ↗
54. Reduced clot permeability and susceptibility to lysis in patients with acute coronary syndrome: effects of inflammation and oxidative stress10.1016/j.atherosclerosis.2007.05.028 ↗
55. Altered fibrin clot structure/function in patients with idiopathic venous thromboembolism and in their relatives10.1182/blood-2009-05-222380 ↗
56. The significance of red cell surface area to the permeability of fibrin network
57. A constitutive model for developing blood clots with various compositions and their nonlinear viscoelastic behavior10.1007/s10237-015-0686-9 ↗
58. Separating viscoelasticity and poroelasticity of gels with different length and time scales10.1007/s10409-014-0015-z ↗
59. The hydraulic permeability of blood clots as a function of fibrin and platelet density10.1016/j.bpj.2013.02.055 ↗
60. Model predictions of deformation, embolization and permeability of partially obstructive blood clots under variable shear flow10.1098/rsif.2017.0441 ↗
61. Some forms of the strain energy function for rubber10.5254/1.3538343 ↗
62. Stress-relaxation behavior in gels with ionic and covalent crosslinks10.1063/1.3343265 ↗
63. A three-dimensional phase-field model for multiscale modeling of thrombus biomechanics in blood vessels10.1371/journal.pcbi.1007709 ↗