Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study
Source abstract
Abstract
OBJECTIVES: To investigate in a numerical study the effect of the geometry and the extension of orthodontic aligner edges and the aligner thickness on force transmission to upper right central incisor tooth (Tooth 11). METHODS: A three-dimensional (3D) digital model, obtained from a 3D data set of a complete dentulous maxilla, was imported into 3-matic software. Aligners with four different trimming line designs (scalloped, straight, scalloped extended, straight extended) were designed, each with four different thicknesses (0.3, 0.4, 0.5, and 0.6 mm). The models were exported to a finite element (FE) software (Marc/Mentat). A facial 0.2 mm bodily malposition of tooth 11 was simulated. RESULTS: The maximum resultant force was in the range of (7.5 - 55.2) N. The straight trimming designs had higher resultant force than the scalloped designs. The resultant force increases with increasing the edge extension of the aligner. The normal contact forces were unevenly distributed over the entire surface and were concentrated in six areas: Incisal, Mesio-Incisal, Disto-Incisal, Middle, Mesio-Cervical, and Disto-Cervical. The resultant force increases super linearly with increasing thickness. CONCLUSIONS: The design of the trimming line, the edge extension, and the thickness of the aligner affect significantly the magnitude of the resultant force and the distribution of normal contact force. The straight extended trimming design exhibited better force distribution that may favor a bodily tooth movement. CLINICAL RELEVANCE: A straight extended trimming design of an orthodontic aligner may improve the clinical outcomes. In addition, the manufacturing procedures of the straight design are much simpler compared to the scalloped design.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Periodontal health in teenagers treated with removable aligners and fixed orthodontic appliances10.1007/s00056-015-0285-5 ↗
2. Biomechanical behavior of endodontically treated premolars restored with different endocrown designs: finite element study10.1016/j.jmbbm.2022.105309 ↗
3. Effect of shrinking and no shrinking dentine and enamel replacing materials in posterior restoration: a 3D-FEA study10.3390/app11052215 ↗
4. A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances10.1007/s10439-007-9424-5 ↗
5. Design of customised orthodontic devices by digital imaging and CAD/FEM modelling
6. Computer aided modelling to simulate the biomechanical behaviour of customised orthodontic removable appliances10.1007/s12008-014-0246-z ↗
7. Computational design and engineering of polymeric orthodontic aligners10.1002/cnm.2839 ↗
8. Three-dimensional diagnosis andorthodontic treatment of complex malocclusions with the invisalign appliance
9. Brown · 2021
10. Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment10.1186/s12903-015-0091-x ↗
11. Experimental study of the pressures and points of application of the forces exerted between aligner and tooth10.3390/nano9071010 ↗
12. Cowley · 2012 · 1662
13. The effect of gingival-margin design on the retention of thermoformed aligners
14. Influence of orthodontic appliance design on employment hiring preferences10.1016/j.ajodo.2018.12.020 ↗
15. Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation10.1007/s00056-015-0307-3 ↗
16. Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: an in vitro study10.2319/011316-37R.1 ↗
17. Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: an in-vitro study10.1016/j.ajodo.2016.08.020 ↗
18. Effect of different attachment geometries on the mechanical load exerted by PET-G aligners during derotation of mandibular canines10.1007/s00056-019-00193-7 ↗
19. Elshazly · 2023
20. Computer-aided finite element model for biomechanical analysis of orthodontic aligners
21. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: an in vitro study10.1016/j.jdent.2022.104276 ↗
22. Potential application of 4D technology in fabrication of orthodontic aligners10.3389/fmats.2021.794536 ↗
23. Effect of aging of orthodontic aligners in different storage media on force and torque generation: an in vitro study10.3390/oral3010007 ↗
24. Effect of thermomechanical aging of orthodontic aligners on force and torque generation: an in vitro study
25. T. Elshazly, D. Salvatori, C. Bourauel et al., Effect of Thickness and Material Type of Orthodontic Aligners on Force Transmission: an in Vitro Study Using Pressure-Sensitive Films, Available SSRN 4270102.
26. Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion10.2319/090216-666.1 ↗
27. B. Golkhani, A. Weber, L. Keilig et al., Variation of the modulus of elasticity of aligner foil sheet materials due to thermoforming, J. Orofac. Orthop. 83 (2022), 233–243. https://doi.org/10.1007/s00056-021-00327-w.10.1007/s00056-021-00327-w ↗
28. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis10.2319/050714-330.1 ↗
29. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping10.1016/j.ajodo.2008.12.015 ↗
30. Initial forces generated by three types of thermoplastic appliances on an upper central incisor during tipping10.1093/ejo/cjp047 ↗
31. Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor10.2319/033009-181.1 ↗
32. Torquing an upper central incisor with aligners acting forces and biomechanical principles10.1093/ejo/cjq007 ↗
33. Effects of different aligner materials and attachments on orthodontic behavior10.1016/j.jds.2021.01.011 ↗
34. Torque capabilities of self-ligating and conventional brackets under the effect of bracket width and free wire length10.1111/j.1601-6343.2012.01553.x ↗
35. Orthodontic aligner incorporating eucommia ulmoides exerts low continuous force: in vitro study10.3390/ma13184085 ↗
36. Influence of constant strain on the elasticity of thermoplastic orthodontic materials
37. Retention of thermoformed aligners with attachments of various shapes and positions
38. Numerical simulation and biomechanical analysis of an orthodontically treated periodontally damaged dentition10.1007/s00056-013-0182-8 ↗
39. Force delivery properties of thermoplastic orthodontic materials10.1016/j.ajodo.2006.03.034 ↗
40. Three-dimensional numerical simulation of stress induced by different lengths of osseointegrated implants in the anterior maxilla10.1080/10255842.2012.654780 ↗
41. Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners
42. Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor10.4041/kjod.2016.46.2.65 ↗
43. Effect of thermoplastic appliance thickness on initial stress distribution in periodontal ligament10.1177/1687814015578362 ↗
44. Aligners: the rapidly growing trend in orthodontics around the world
45. The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties10.4041/kjod.2010.40.1.16 ↗
46. Basic concepts of finite element analysis and its applications in dentistry: an overview
47. Nanda · 2010 · 38
48. Proffit · 2000
49. Biomechanical finite-element investigation of the position of the centre of resistance of the upper incisors10.1093/ejo/cjl086 ↗
50. J.-H. Seo, K. Min-Seok, L. Jeong-Hyeon et al., Biomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition—A Finite Element Analysis, Materials 15 (2022), 3118. https://doi.org/10.3390/ma15093118.10.3390/ma15093118 ↗
51. An ultra-thin piezoresistive stress sensor for measurement of tooth orthodontic force in Invisible aligners10.1109/JSEN.2011.2166065 ↗
52. Salivary levels of cariogenic bacterial species during orthodontic treatment with thermoplastic aligners or fixed appliances: a prospective cohort study10.1186/s40510-018-0230-4 ↗
53. Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization10.1016/j.ajodo.2014.03.015 ↗
54. Pressure differences from clear aligner movements assessed by pressure sensors
55. Orthodontic treatment with clear aligners and the scientific reality behind their marketing: a literature review10.5152/TurkJOrthod.2019.18083 ↗
56. Tuncay · 2006
57. Biomechanics of clear aligners: hidden truths & first principles
58. Biomechanics in orthodontics
59. In-vivo von Mises strains during Invisalign treatment10.1016/j.ajodo.2008.11.027 ↗
60. The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva10.1038/s41598-021-89425-8 ↗
61. Clinical effectiveness of clear aligner treatment compared to fixed appliance treatment: an overview of systematic reviews
62. Zamani · 2022