journal article·2023-04Open access

Effect of various printing parameters on the accuracy (trueness and precision) of 3D-printed partial denture framework

Anastasiia Grymak, Abdelrahman Badarneh, Sunyoung Ma, Joanne Jung Eun Choi

Abstract

OBJECTIVES: To measure and compare the accuracy of 3D-printed materials used for RPD production to improve workflow and eliminate errors in manufacturing. METHODS: A partially edentulous maxilla (Kennedy Class III, modification 1) was prepared and designed with proximal plates, rest seats and clasps in one first premolar, one canine and two second molars. A total of 540 3D printed RPD frameworks were 3D printed with three different types of resin (DentaCAST (Asiga, Australia), SuperCAST (Asiga, Australia) and NextDent (3D Systems, Netherlands)). To evaluate the trueness of the printing materials, they were printed with three types of layer thickness: 50 μm, 75 μm and 100 μm, using two types of build angles: 0° and 45° and three types of plate locations: side, middle and corner. After production, all specimens were scanned and superimposed with a control sample that was digitally designed. Using the initial alignment and best-fit alignment method, the root mean square error (RMSE) was calculated. To capture region specific discrepancy, 10 points of XYZ internal discrepancy within RPDs were measured and Euclidean error was calculated. Data was statistically analysed using Shapiro-Wilk and Kruskal-Wallis tests, one-way ANOVA and T-test (SPSS Version 29) and MATLAB (R2022b). RESULTS: Optimal results were found using 45°, middle of the build plate and layer thicknesses of 100 μm (115 ± 19 μm, DentaCAST), 75 μm (143 ± 14 μm, NextDent), 50 μm (98 ± 35 μm, SuperCAST), which were clinically acceptable. Results were statistically significant when comparing layer thickness in each testing group (p < 0.001). Layer thickness was a primary parameter in the determination of print accuracy among all materials (p < 0.001). Higher discrepancies and failures were observed in 0° prints. No statistically significant difference was found in material usage between build angles or layer thickness (p > 0.005). CONCLUSIONS: All three 3D printing materials exhibited clinically acceptable RMSE results with a build angle of 45° with a printing layer thickness of 50 μm for SuperCAST, 75 μm NextDent and 100 μm for DentaCAST. The highest discrepancies were mostly found in posterior clasps, while the lowest discrepancy was found in palatal straps. Despite unoptimized spacing of prints, frameworks configured to print in the middle of the build plate result in the least printing failures.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Dental Research and COVID-19

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Accuracy · 1994
2. Fit accuracy of removable partial denture frameworks fabricated with CAD/CAM, rapid prototyping, and conventional techniques: a systematic review
3. Part orientation and build cost determination in layered manufacturing10.1016/S0010-4485(97)00083-3 ↗
4. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations10.1016/j.prosdent.2015.12.002 ↗
5. Surface quality of 3D-printed models as a function of various printing parameters10.3390/ma12121970 ↗
6. Photopolymerization in 3D printing10.1021/acsapm.8b00165 ↗
7. Bouaziz · 2016 · 1
8. Production tolerance of additive manufactured polymeric objects for clinical applications10.1016/j.dental.2016.03.020 ↗
9. Determining optimal parameters for stereolithography processes via genetic algorithm10.1016/S0278-6125(00)88887-1 ↗
10. The effect of storage time of removable partial denture wax pattern on the accuracy of fit of the cast framework10.1016/S0022-3913(97)70162-8 ↗
11. Mechanical characterization of 3D-printed polymers
12. A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies10.1016/j.prosdent.2006.02.001 ↗
13. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models10.1016/j.ajodo.2017.06.012 ↗
14. Effect of anchorage on the accuracy of fit in removable partial denture framework10.1111/j.1532-849X.2010.00594.x ↗
15. Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters10.4047/jap.2022.14.3.150 ↗
16. The effect of the angle of acuteness of additive manufactured models and the direction of printing on the dimensional fidelity: clinical implications10.1007/s10266-016-0239-4 ↗
17. Effects of post-curing time on the mechanical and color properties of three-dimensional printed crown and bridge materials10.3390/polym12112762 ↗
18. A neural network approach to the modelling and analysis of stereolithography processes. Proceedings of the Institution of Mechanical Engineers, Part B10.1177/095440540121501206 ↗
19. Influence of the rinsing postprocessing procedures on the manufacturing accuracy of vat‐polymerized dental model material10.1111/jopr.13288 ↗
20. Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment10.1016/j.dental.2019.01.012 ↗
21. Accuracy of metal 3D printed frameworks for removable partial dentures evaluated by digital superimposition10.1016/j.dental.2021.12.012 ↗
22. Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics10.3390/ma12162533 ↗
23. Effects of environmental conditions, aging, and build orientations on the mechanical properties of ASTM type I specimens manufactured via stereolithography10.1108/13552541211250373 ↗
24. Color dimensions of additive manufactured interim restorative dental material10.1016/j.prosdent.2019.06.001 ↗
25. Influences of build angle on the accuracy, printing time, and material consumption of additively manufactured surgical templates10.1016/j.prosdent.2020.09.012 ↗
26. Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations10.1016/j.prosdent.2019.05.034 ↗
27. An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks10.1111/jopr.12997 ↗
28. Clinical evaluation of removable partial denture rest seat adaptation10.1016/0022-3913(85)90015-0 ↗
29. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering10.1016/j.jpor.2019.07.009 ↗
30. Evaluation of removable partial denture frameworks fabricated using 3 different techniques10.1016/j.prosdent.2018.10.013 ↗
31. Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin10.1016/j.dental.2018.09.011 ↗
32. Anisotropicity of flexural properties of occlusal splint material processed by stereolithography10.1016/j.prosdent.2016.03.018 ↗
33. Accuracy of orthodontic models prototyped for clear aligners therapy: a 3D imaging analysis comparing different market segments 3D printing protocols10.1016/j.jdent.2022.104212 ↗
34. Influence of the three-dimensional printing technique and printing layer thickness on model accuracy10.1007/s00056-019-00180-y ↗