An improved trabecular bone model based on Voronoi tessellation
Source abstract
Abstract
BACKGROUND AND OBJECTIVE: Accurate numerical and physical models of trabecular bone, correctly representing its complexity and variability, could be highly advantageous in the development of e.g. new bone-anchored implants due to the limited availability of real bone. Several Voronoi tessellation-based porous models have been reported in the literature, attempting to mimic the trabecular bone. However, these models have been limited to lattice rod-like structures, which are only structurally representative of very high-porosity trabecular bone. The objective of this study was to provide an improved model, more representative of trabecular bone of different porosity. METHODS: Boolean operations were utilized to merge scaled Voronoi cells, thereby introducing different structural patterns, controlling porosity and to some extent anisotropy. The mechanical properties of the structures were evaluated using analytical estimations, numerical simulations, and experimental compression tests of 3D-printed versions of the structures. The capacity of the developed models to represent trabecular bone was assessed by comparing some key geometric features with trabecular bone characterized in previous studies. RESULTS: The models gave the possibility to provide pore interconnectivity at relatively low porosities as well as both plate- and rod-like structures. The mechanical properties of the generated models were predictable with numerical simulations as well as an analytical approach. The permeability was found to be better than Sawbones at the same porosity. The models also showed the capability of matching e.g. some vertebral structures for key geometric features. CONCLUSIONS: An improved numerical model for mimicking trabecular bone structures was successfully developed using Voronoi tessellation and Boolean operations. This is expected to benefit both computational and experimental studies by providing a more diverse and representative structure of trabecular bone.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone health and osteoporosis research · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. A fast voxel traversal algorithm for ray tracing
2. Microarchitecture influences microdamage accumulation in human vertebral trabecular bone10.1359/jbmr.080517 ↗
3. 2007
4. Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response10.1016/j.cmpb.2023.107342 ↗
5. Bennani Kamane · 2012
6. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography10.1002/jbmr.141 ↗
7. Braam · 2022
8. Bone-derived CAD library for assembly of scaffolds in computer-aided tissue engineering10.1080/17452750801911352 ↗
9. Development of a tissue engineering scaffold structure library for rapid prototyping. Part 2: parametric library and assembly program10.1007/s001700300035 ↗
10. Age-and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck10.1007/s00198-009-0993-z ↗
11. Design and properties of biomimetic irregular scaffolds for bone tissue engineering10.1016/j.compbiomed.2021.104241 ↗
12. Conway · 2013 · vol. 290
13. Porous polylactic acid scaffolds for bone regeneration: a study of additively manufactured triply periodic minimal surfaces and their osteogenic potential10.1177/2041731420956541 ↗
14. Hexagonal pore geometry and the presence of hydroxyapatite enhance deposition of mineralized bone matrix on additively manufactured polylactic acid scaffolds10.1016/j.msec.2021.112091 ↗
15. Accuracy of cancellous bone volume fraction measured by micro-CT scanning10.1016/S0021-9290(98)00176-6 ↗
16. The ellipsoid factor for quantification of rods, plates, and intermediate forms in 3D geometries10.3389/fendo.2015.00015 ↗
17. A method to design biomimetic scaffolds for bone tissue engineering based on Voronoi lattices10.1080/17452759.2016.1172301 ↗
18. Role of trabecular microarchitecture in whole‐vertebral body biomechanical behavior10.1359/jbmr.090317 ↗
19. Design and assessment of the biomimetic capabilities of a Voronoi-based cancellous microstructure10.1016/j.jmbbm.2022.105186 ↗
20. Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians
21. Gibson · 1999
22. Design and properties of 3D scaffolds for bone tissue engineering10.1016/j.actbio.2016.06.032 ↗
23. The potential of stereolithography for 3D printing of synthetic trabecular bone structures
24. Hakenberg · 2014
25. Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor10.1007/BF00540446 ↗
26. Hibbitt · 1992
27. Quantification of bone microarchitecture with the structure model index10.1080/01495739708936692 ↗
28. Characterization of a polymer, open-cell rigid foam that simulates the ultrasonic properties of cancellous bone10.1121/1.5023219 ↗
29. Jacobson
30. Generation of periodic stochastic foam models for numerical analysis10.1177/0021955X13503848 ↗
31. A simple and effective geometric representation for irregular porous structure modelling10.1016/j.cad.2010.06.006 ↗
32. Porous three-dimensional scaffold generation for 3D printing10.3390/math8060946 ↗
33. Spatial modeling of bone microarchitecture
34. The design and evaluation of bionic porous bone scaffolds in fluid flow characteristics and mechanical properties10.1016/j.cmpb.2022.107059 ↗
35. Contributions of trabecular rods of various orientations in determining the elastic properties of human vertebral trabecular bone10.1016/j.bone.2009.04.201 ↗
36. Min
37. Regional, age and gender differences in architectural measures of bone quality and their correlation to bone mechanical competence in the human radius of an elderly population10.1016/j.bone.2009.06.031 ↗
38. Muir
39. Three-dimensional methods for quantification of cancellous bone architecture10.1016/S8756-3282(97)00007-0 ↗
40. Okabe · 2000
41. Pullout strength of suture anchors: effect of mechanical properties of trabecular bone10.1016/j.jbiomech.2009.12.007 ↗
42. Multi-axial mechanical properties of human trabecular bone10.1007/s10237-008-0128-z ↗
43. In vivo assessment of local effects after application of bone screws delivering bisphosphonates into a compromised cancellous bone site10.1016/j.clinbiomech.2011.06.004 ↗
44. ImageJ2: ImageJ for the next generation of scientific image data10.1186/s12859-017-1934-z ↗
45. Schneider · 2002
46. Composition and microarchitecture of human trabecular bone change with age and differ between anatomical locations10.1016/j.bone.2013.01.045 ↗
47. Analysis of microstructural and mechanical alterations of trabecular bone in a simulated three-dimensional remodelling process10.1016/j.jbiomech.2012.06.024 ↗
48. Design and compressive behavior of controllable irregular porous scaffolds: based on voronoi-tessellation and for additive manufacturing10.1021/acsbiomaterials.7b00916 ↗
49. Insertion angle impact on primary stability of orthodontic mini-implants10.2319/100707-484.1 ↗
50. 3D-printed PLA/HA composite structures as synthetic trabecular bone: a feasibility study using Fused Deposition Modelling
51. 3D-printed PLA/HA composite structures as synthetic trabecular bone: a feasibility study using fused deposition modeling10.1016/j.jmbbm.2019.103608 ↗
52. Zheng · 2020