Developing porous hip implants implementing topology optimization based on the bone remodelling model and fatigue failure
Source abstract
Abstract
In contemporary orthopaedic practice, total hip arthroplasty (THA) is a reliable surgical technique for hip joint replacement. However, introducing solid implants into human bone tissue can lead to complications, notably stress shielding and cortical hypertrophy. These issues often stem from mechanical mismatches, particularly stiffness disparities, between the solid implants and the bone tissue. A potential solution lies in adopting porous implant structures with lower stiffness and tuneable mechanical properties based on morphological parameters such as porosity, relative density, and unit cell sizes. This study, which is of significant importance to orthopaedic implant development, aims to develop porous implants that meet biological and manufacturing requirements, employing topology optimization methods to address the challenges associated with conventional solid implants. To achieve this objective, we conducted finite element analyses to compare the stress distribution within healthy bones with solid and newly developed porous implants under real-life loading conditions. The porous implants were designed with triply periodic minimal surface structures, featuring uniform relative density and gradient relative density mapping derived from topology optimization results considering additive manufacturing capabilities and biological constraints. Our findings provide critical insights into the impact on the bone's mechanical environment about the choice of implant. Specifically, solid implants significantly decrease applied stress within the cortical bone, leading to stress shielding and subsequent bone resorption, consistent with bone remodelling principles and Wolff's law. However, replacing the solid implant with uniform porosity with maximum compliance and employing gradient porous implants based on topology optimization methods significantly increases the strain energy density ratio. Specifically, the uniform gyroid, uniform diamond, gradient gyroid, and gradient diamond stems exhibited increases of 43%, 39%, 27%, and 25%, respectively, compared to the solid stem, effectively mitigating the stress shielding effect. However, amongst porous stems, only gradient designs could meet the mechanical strength requirements with a safety factor greater than one, rendering them suitable replacements for solid implants aimed at addressing associated complications. These results hold promise, particularly with the advancements in additive manufacturing methods capable of fabricating these porous implants with acceptable precision.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (80)
Show source-provided references
1. Design, optimization, and selective laser melting of vin tiles cellular structure-based hip implant10.1007/s00170-020-06323-5 ↗
2. Mechanical and fatigue properties of Ti-6Al-4V alloy fabricated using binder jetting process and subjected to hot isostatic pressing10.3390/ma17153825 ↗
3. Use of compression test to determine the Young's modulus of the titanium alloy Ti6Al4V manufactured via direct metal laser sintering10.1556/1848.2022.00536 ↗
4. Finite element analysis of porous titanium alloy hip stem to evaluate the biomechanical performance during walking and stair climbing10.1007/s42235-019-0122-4 ↗
5. Finite element study of functionally graded porous femoral stems incorporating body‐centered cubic structure10.1111/aor.13444 ↗
6. Metallic scaffolds for bone regeneration10.3390/ma2030790 ↗
7. Fatigue design of a mechanically biocompatible lattice for a proof-of-concept femoral stem10.1016/j.jmbbm.2013.03.002 ↗
8. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty10.1002/jor.23445 ↗
9. Quasi-Static compressive responses and fatigue behaviour of Ti-6Al-4 V graded lattice structures fabricated by laser powder bed fusion10.1016/j.matdes.2021.110110 ↗
10. Synthetic bone: design by additive manufacturing10.1016/j.actbio.2019.07.049 ↗
11. Bendsøe · 2004
12. IS staircase walking a RISK for the fixation OF HIP implants?10.1016/0021-9290(94)00105-D ↗
13. Method of computational design for additive manufacturing of hip endoprosthesis based on basic-cell concept10.1002/cnm.3802 ↗
14. Total hip arthroplasty: techniques and results
15. Distal femoral cortical hypertrophy after hip arthroplasty using a cementless double-tapered femoral stem10.1177/1602400309 ↗
16. Additive manufacturing structural redesign of hip prostheses for stress-shielding reduction and improved functionality and safety10.1016/j.mechmat.2021.104173 ↗
17. Mechanical behavior of materials: engineering methods for deformation
18. Effect of solution treatment and cooling rate on the microstructure and hardness of Ti-6Al-4V alloy manufactured by selective laser melting before and after hot isostatic pressing treatment10.1007/s11665-021-06489-3 ↗
19. Microstructure and mechanical properties of Ti-6Al-4V manufactured by selective laser melting after stress relieving, hot isostatic pressing treatment, and post-heat treatment10.1007/s11665-021-05753-w ↗
20. Mechanical properties and deformation behavior of functionally graded TPMS structures under static and dynamic loading10.1016/j.ijimpeng.2023.104554 ↗
21. Migration pattern of a femoral short-stem prosthesis: a 2-year EBRA-FCA-study10.1007/s00402-014-1984-x ↗
22. Impact of post-process heat treatments performed on Ti6Al4V titanium alloy specimens obtained using LPBF technology10.3390/technologies11040100 ↗
23. Parametric design of hip implant with gradient porous structure10.3389/fbioe.2022.850184 ↗
24. Multi-objective design optimization of 3D micro-architected implants10.1016/j.cma.2022.115102 ↗
25. Gibson · 1997
26. On the design evolution of hip implants: a review
27. Solid-lattice hip prosthesis design: applying topology and lattice optimization to reduce stress shielding from hip implants
28. Determination of muscle loading at the hip joint for use in pre-clinical testing10.1016/j.jbiomech.2004.05.022 ↗
29. Adaptive bone-remodeling theory applied to prosthetic-design analysis10.1016/0021-9290(87)90030-3 ↗
30. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
31. Femoral stem incorporating a diamond cubic lattice structure: design, manufacture and testing10.1016/j.jmbbm.2017.08.034 ↗
32. Design and characterization of sheet-based gyroid porous structures with bioinspired functional gradients10.3390/ma13173844 ↗
33. Radiological evaluation of the relationship between cortical hypertrophy and stress shielding after total hip arthroplasty using a cementless stem10.1016/j.artd.2020.09.018 ↗
34. Finite element analysis of orthopedic hip implant with functionally graded bioinspired lattice structures10.3390/biomimetics5030044 ↗
35. Rationally designed meta-implants: a combination of auxetic and conventional meta-biomaterials10.1039/C7MH00699C ↗
36. Enhancement in the fatigue resistances of triply periodic surfaces-based scaffolds10.1016/j.ijmecsci.2023.108119 ↗
37. The influence of selective laser melting defects on the fatigue properties of Ti6Al4V porosity graded gyroids for bone implants10.1016/j.ijmecsci.2020.106180 ↗
38. A comprehensive analysis of bio-inspired design of femoral stem on primary and secondary stabilities using mechanoregulatory algorithm10.1007/s10237-020-01334-3 ↗
39. Finite element modelling and characterization of 3D cellular microstructures for the design of a cementless biomimetic porous hip stem10.1016/j.matdes.2018.04.002 ↗
40. A novel design, analysis and 3D printing of Ti-6Al-4V alloy bio-inspired porous femoral stem10.1007/s10856-020-06420-7 ↗
41. Melchels · 2010
42. Influence of cleaning process on mechanical properties and surface characteristics of selective laser melted Ti6Al4V parts prepared for medical implant applications10.1557/s43578-022-00630-1 ↗
43. Effects of porous tantalum on periprosthetic bone remodeling around metaphyseal filling femoral stem: a multicenter, prospective, randomized controlled study10.1038/s41598-022-04936-2 ↗
44. A novel hybrid design and modelling of a customised graded Ti-6Al-4V porous hip implant to reduce stress-shielding: an experimental and numerical analysis10.3389/fbioe.2023.1092361 ↗
45. Mechanical characterisation and numerical modelling of TPMS-based gyroid and diamond Ti6Al4V scaffolds for bone implants: an integrated approach for translational consideration10.3390/bioengineering9100504 ↗
46. Cortical hypertrophy in total hip arthroplasty with cementless stem
47. Mechanical performance and fatigue life prediction of lattice structures: parametric computational approach10.1016/j.compstruct.2019.111821 ↗
48. Thermal characterization of 3D-Printed lattices based on triply periodic minimal surfaces embedded with organic phase change material10.1016/j.csite.2021.101315 ↗
49. Study of cellular femoral stem for stress shielding and interface stability10.1177/03913988231168158 ↗
50. Design parameters effects on relative density of triply periodic minimal surfaces for additive manufacturing
51. Design and manufacturing of patient-specific Ti6Al4V implants with inhomogeneous porosity10.1016/j.jmbbm.2023.105925 ↗
52. Selective laser melted Ti6Al4V split-P TPMS lattices for bone tissue engineering10.1016/j.ijmecsci.2023.108353 ↗
53. Distal cortical hypertrophy following total hip arthroplasty10.1016/S0883-5403(88)80076-7 ↗
54. Biomechanical effects of the porous structure of gyroid and voronoi hip implants: a finite element analysis using an experimentally validated model10.3390/ma16093298 ↗
55. Preoperative planning of total hip arthroplasty
56. Topology optimization approaches: a comparative review10.1007/s00158-013-0978-6 ↗
57. Heterogeneous modeling based prosthesis design with porosity and material variation10.1016/j.jmbbm.2018.07.029 ↗
58. Physiologically based boundary conditions in finite element modelling10.1016/j.jbiomech.2006.10.038 ↗
59. Wolff's law (bone functional adaptation)
60. Biomechanical optimization of elastic modulus distribution in porous femoral stem for artificial hip joints10.1007/s42235-018-0057-1 ↗
61. Designing patient-specific 3D printed craniofacial implants using a novel topology optimization method10.1007/s11517-015-1418-0 ↗
62. Topology optimisation for compliant hip implant design and reduced strain shielding10.3390/ma14237184 ↗
63. Fabrication and characterization of porous bone scaffold of bovine hydroxyapatite-glycerin by 3D printing technology10.1016/j.bprint.2020.e00078 ↗
64. Total hip arthroplasty techniques
65. Selective laser melted Ti-6Al-4V alloy after post-heat treatments: microstructure, mechanical properties and fatigue behavior
66. Multi-scale surface treatments of titanium implants for rapid osseointegration: a review
67. On the design and properties of porous femoral stems with adjustable stiffness gradient10.1016/j.medengphy.2020.05.003 ↗
68. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: a review
69. Hip implant design with three-dimensional porous architecture of optimized graded density10.1115/1.4041208 ↗
70. Waqas, M., He, D., Liu, Y., Riaz, S., Afzal, F., n.d. Effect of Heat Treatment on Microstructure and Mechanical Properties of Ti6Al4V Alloy Fabricated by Selective Laser Melting. https://doi.org/10.1007/s11665-022-07106-7.10.1007/s11665-022-07106-7 ↗
71. Effects of material properties of femoral hip components on bone remodeling10.1002/jor.1100100614 ↗
72. Sensitivity of periprosthetic stress-shielding to load and the bone density–modulus relationship in subject-specific finite element models10.1016/S0021-9290(00)00036-1 ↗
73. Wolff · 1986
74. Topology optimization of multi-scale structures: a review10.1007/s00158-021-02881-8 ↗
75. Fatigue performances of selective laser melted Ti-6Al-4V alloy: influence of surface finishing, hot isostatic pressing and heat treatments10.1016/j.ijfatigue.2018.11.019 ↗
76. Study on the tensile and shear behaviors of selective laser melting manufactured Ti6Al4V10.1007/s12540-023-01433-7 ↗
77. Evaluation of fatigue life for dental implants using FEM analysis10.3390/prosthesis3040028 ↗
78. Advanced porous hip implants: a comprehensive review10.1016/j.heliyon.2024.e37818 ↗
79. Exploring the optimal mechanical properties of triply periodic minimal surface structures for biomedical applications: a Numerical analysis10.1016/j.jmbbm.2024.106757 ↗
80. Design of titanium alloy femoral stem cellular structure for stress shielding and stem stability: computational analysis10.3390/app12031548 ↗