FEM wear prediction of ceramic hip replacement bearings under dynamic edge loading conditions

K. Nitish Prasad, P. Ramkumar

Publisher page

Abstract

Hard-on-Hard hip implants, specifically ceramic tribo-pair, have produced the highest in-vivo wear resistance, biocompatibility, superior corrosion resistance, and high fracture toughness. However, this ceramic tribo-pair suffers from edge loading, sharply increasing wear and accelerating early implant failures due to micro-separation. Even though in-vitro studies have tested the occurrence of wear due to dynamic edge loading, the Finite Element Method (FEM) gives the advantage of accurately estimating the wear, minimizing the experimental time and cost. A new fundamental FEM model is developed to predict wear for ceramic hip replacement bearings under dynamic edge loading conditions for a fixed separation and fixed inclination angle. The model is directly validated with the existing hip simulator data up to 3 million cycles in terms of wear depth, wear scar and volumetric wear rate. The results from the model show that the accuracy in wear prediction was more than 98% for the wear depth and volumetric wear rate for the dynamic edge loading condition. A stripe wear scar is captured, depicting the edge loading conditions. The developed model from this study can predict wear under pure standard and dynamic edge loading conditions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Retrieval analysis of three generations of Biolox® femoral heads: spectroscopic and SEM characterisation10.1016/j.jmbbm.2012.04.003 ↗
2. Wear of 36-mm BIOLOX delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions10.1177/0954411912474613 ↗
3. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement10.1002/jbm.b.31708 ↗
4. The influence of kinematic conditions and variations in component positioning on the severity of edge loading and wear of ceramic-on-ceramic hip bearings10.3390/ceramics2030037 ↗
5. Ali
6. The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis10.1115/1.4001031 ↗
7. Is patient satisfaction related to patient reported sounds from ceramic on ceramic total hip arthroplasty? A study of 265 hips10.1007/s00590-019-02426-2 ↗
8. Analysis of micro-separation and contact mechanics between the femoral head and the acetabular cup in artificial hip joint replacements
9. Implant wear mechanisms - basic approach10.1088/1748-6041/3/4/042001 ↗
10. Chemically driven tetragonal-to-monoclinic polymorphic transformation in retrieved ZTA femoral heads from dual mobility hip implants10.1016/j.jmbbm.2015.11.032 ↗
11. Finite element method based sliding wear prediction of steel-on-steel contacts using extrapolation techniques10.1177/1350650119836813 ↗
12. Slide track analysis of eight contemporary hip simulator designs10.1016/S0021-9290(02)00171-9 ↗
13. 2015
14. Ceramics for medical applications: a picture for the next 20 years10.1016/j.jeurceramsoc.2008.08.025 ↗
15. Submodeling in wear predictive finite element models with multipoint contacts10.1002/nme.6682 ↗
16. A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants10.1016/j.triboint.2014.10.023 ↗
17. Wear in alumina-on-alumina ceramic total hip replacements: a retrieval analysis of edge loading10.1302/0301-620X.94B7.29115 ↗
18. Computationally efficient modelling of hip replacement separation due to small mismatches in component centres of rotation10.1016/j.jbiomech.2019.07.040 ↗
19. Finite element analysis of sliding distance and contact mechanics of hip implant under dynamic walking conditions10.1177/0954411915585380 ↗
20. Effect of grain size on hertzian contact damage in alumina10.1111/j.1151-2916.1994.tb07057.x ↗
21. Effect of heat treatment on wear damage mechanisms in 3Y-TZP ceramics10.1016/j.wear.2010.03.004 ↗
22. Ceramic on ceramic bearings10.31524/bkkmedj.2012.09.015 ↗
23. Advances in Zirconia toughened alumina biomaterials for total joint replacement10.1016/j.jmbbm.2013.03.022 ↗
24. Complications of ceramic-on-ceramic bearings: fracture, stripe wear, and squeaking10.1007/978-3-319-54913-2_14 ↗
25. A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements10.1016/j.jmbbm.2018.04.018 ↗
26. Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints10.1016/j.triboint.2017.01.012 ↗
27. Enhanced computational modelling of UHMWPE wear in total hip joint replacements: the role of frictional work and contact pressure
28. Enhanced computational modelling of UHMWPE wear in total hip joint replacements: the role of frictional work and contact pressure
29. Development of computational wear simulation of metal-on-metal hip resurfacing replacements10.1016/j.jbiomech.2007.09.020 ↗
30. A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture10.1186/s13018-022-03190-6 ↗
31. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses10.1016/j.arth.2009.10.019 ↗
32. Mak1 · 2002
33. Does Biolox® Delta ceramic reduce the rate of component fractures in total hip replacement?10.1016/j.otsr.2014.05.010 ↗
34. Materials for hip prostheses: a review of wear and loading considerations10.3390/ma12030495 ↗
35. Computational method for bearing surface wear prediction in total hip replacements
36. Non-cytotoxic and non-genotoxic wear debris of strontium oxide doped (Zirconia Toughened Alumina) (SrO-ZTA) implant for hip prosthesis10.1016/j.matchemphys.2021.125187 ↗
37. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns10.1054/arth.2000.8100 ↗
38. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions10.1016/S0142-9612(00)00361-6 ↗
39. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements10.1002/jbm.b.33991 ↗
40. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators [1] (multiple letters)10.1016/S0021-9290(03)00074-5 ↗
41. In vitro investigation of friction under edge-loading conditions for ceramic-on-ceramic total hip prosthesis10.1002/jor.21100 ↗
42. Finite element submodeling technique to analyze the contact pressure and wear of hard bearing couples in hip prosthesis10.1080/10255842.2020.1734794 ↗
43. Wear prediction of hard carbon coated hard-on-hard hip implants using finite element method10.1504/IJCAET.2018.092844 ↗
44. Nanotechnology and precision engineering tribological performance of bioimplants : a comprehensive review
45. Tribological performance of some alternative bearing materials for artificial joints10.1016/S0043-1648(03)00276-X ↗
46. Wear mechanisms in ceramic hip implants
47. How does bicycling affect the longevity of Total Hip Arthroplasty? A finite element wear analysis10.1016/j.jmbbm.2023.105673 ↗
48. Predicting the wear of hard-on-hard hip joint prostheses10.1016/j.wear.2013.01.009 ↗
49. Retrieval analysis of squeaking alumina ceramic-on-ceramic bearings10.1302/0301-620X.93B12.27529 ↗
50. Finite element analysis of polyethylene wear in total hip replacement: a literature review10.1177/0954411919872630 ↗
51. Release of metal ions from nano CoCrMo wear debris generated from tribo-corrosion processes in artificial hip implants10.1016/j.jmbbm.2017.01.041 ↗
52. Total hip arthroplasty using hybrid ceramic bearing: a minimum 10-year followup study10.4103/ortho.IJOrtho_416_18 ↗
53. Design of low wear artificial hip joint considering 3D physiological loading and motion10.1016/j.wear.2023.204744 ↗