Macro-indentation testing of soft biological materials and assessment of hyper-elastic material models from inverse finite element analysis
Source abstract
Abstract
Mechanical characterization of hydrogels and ultra-soft tissues is a challenging task both from an experimental and material parameter estimation perspective because they are much softer than many biological materials, ceramics, or polymers. The elastic modulus of such materials is within the 1 - 100 kPa range, behaving as a hyperelastic solid with strain hardening capability at large strains. In the current study, indentation experiments have been performed on agarose hydrogels, bovine liver, and bovine lymph node specimens. This work reports on the reliable determination of the elastic modulus by indentation experiments carried out at the macro-scale (mm) using a spherical indenter. However, parameter identification of the hyperelastic material properties usually requires an inverse finite element analysis due to the lack of an analytical contact model of the indentation test. Hence a comprehensive study on the spherical indentation of hyperelastic soft materials is carried out through robust computational analysis. Neo-Hookean and first-order Ogden hyperelastic material models were found to be most suitable. A case study on known anisotropic hyperelastic material showed the inability of the inverse finite element method to uniquely identify the whole material parameter set.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Elasticity and Material Modeling · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (56)
Show source-provided references
1. Advances in bio-tactile sensors for minimally invasive surgery using the fibre Bragg grating force sensor technique: A survey10.3390/s140406633 ↗
2. Biomechanical characterization with inverse FE model parameter estimation: Macro and micro applications10.3795/KSME-A.2009.33.11.1202 ↗
3. Microstructure and mechanics of the bovine trachea: Layer specific investigations through SHG imaging and biaxial testing10.1016/j.jmbbm.2022.105371 ↗
4. Metastatic neck disease. Palpation vs ultrasound examination10.1001/archotol.1989.01860300043013 ↗
5. Development of a mechanical testing assay for fibrotic murine liver10.1118/1.2795665 ↗
6. Shear wave liver elastography10.1007/s00261-017-1375-1 ↗
7. Textural properties of agarose gels. I. Rheological and fracture properties10.1016/j.foodhyd.2005.02.019 ↗
8. Supersonic shear imaging: a new technique for soft tissue elasticity mapping10.1109/TUFFC.2004.1295425 ↗
9. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure10.1016/j.jbiomech.2010.03.038 ↗
10. Local axial compressive mechanical properties of human carotid atherosclerotic plaques—characterisation by indentation test and inverse finite element analysis10.1016/j.jbiomech.2013.03.017 ↗
11. Comparative analysis of indentation and magnetic resonance elastography for measuring viscoelastic properties10.1007/s10409-020-01042-2 ↗
12. Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation10.1007/BF02345212 ↗
13. Lymphatic vessel activation in cancer10.1196/annals.1413.021 ↗
14. Lymphoma of the head and neck.10.1016/S0033-8389(22)01257-X ↗
15. Characterizing white matter tissue in large strain via asymmetric indentation and inverse finite element modeling10.1016/j.jmbbm.2016.09.020 ↗
16. Shear wave elastography for evaluation of liver fibrosis10.7863/ultra.33.2.197 ↗
17. Ultrasound elastography: advantages, limitations and artefacts of the different techniques from a study on a phantom10.1016/j.diii.2013.01.024 ↗
18. Fung · 2013
19. Constitutive modeling of liver tissue: experiment and theory10.1007/s10439-009-9812-0 ↗
20. Spherical indentation of incompressible rubber-like materials10.1016/j.jmps.2006.11.010 ↗
21. Comparison of quantitative shear wave MR-elastography with mechanical compression tests10.1002/mrm.10343 ↗
22. A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue10.1016/S0301-5629(02)00776-7 ↗
23. Stress-driven collagen fiber remodeling in arterial walls10.1007/s10237-006-0049-7 ↗
24. Introduction to instrumented indentation testing10.1111/j.1747-1567.2009.00541.x ↗
25. Modelling non-symmetric collagen fibre dispersion in arterial walls10.1098/rsif.2015.0188 ↗
26. Biomechanics of soft tissue
27. Magnetic resonance elastography of liver-current update10.1097/RMR.0000000000000177 ↗
28. Characterization of soft-tissue material properties: large deformation analysis
29. Normal liver stiffness in healthy adults assessed by real-time shear wave elastography and factors that influence this method10.1016/j.ultrasmedbio.2014.05.008 ↗
30. Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue10.1016/j.jbiomech.2009.03.002 ↗
31. Lee, H., Pharr, G.M., Nahm, S.H., 2003. Material property evaluation of hyper-elastic rubber by micro-indentation. In: Proceedings of the SEM Annual Conference and Exposition on Experimental and Applied Mechanics.
32. A simple indentation device for measuring micrometer-scale tissue stiffness
33. Spherical indentation of soft matter beyond the hertzian regime: numerical and experimental validation of hyperelastic models10.1007/s10237-008-0139-9 ↗
34. Characterizing the micro-scale elastic modulus of hydrogels for use in regenerative medicine10.1016/j.jmbbm.2013.07.008 ↗
35. Assessing liver tumor stiffness by transient elastography10.1007/s12072-007-9012-7 ↗
36. Sample, testing and analysis variables affecting liver mechanical properties: A review10.1016/j.actbio.2016.08.055 ↗
37. The mechanical response of human liver and its relation to histology: an in vivo study10.1016/j.media.2007.06.010 ↗
38. Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography10.1016/j.jmbbm.2019.05.001 ↗
39. A review on material models for isotropic hyperelasticity10.1002/msd2.12013 ↗
40. Method of testing very soft biological tissues in compression10.1016/j.jbiomech.2004.03.004 ↗
41. The stiffness of lymph nodes containing lung carcinoma metastases: a new diagnostic parameter measured by a tactile sensor10.1002/(SICI)1097-0142(19971115)80:10<1920::AID-CNCR8>3.0.CO;2-R ↗
42. Inverse finite element analysis of indentation tests to determine hyperelastic parameters of soft-tissue layers10.1243/03093247JSA485 ↗
43. In vivo mechanical characterization of human liver10.1016/j.media.2007.10.001 ↗
44. Cross-validation of magnetic resonance elastography and ultrasound-based transient elastography: A preliminary phantom study10.1002/jmri.21929 ↗
45. Can hyperelastic material parameters be uniquely determined from indentation experiments?10.1039/C6RA15747E ↗
46. Early and locally advanced non-small-cell lung cancer (NSCLC): ESMO clinical practice guidelines for diagnosis, treatment and follow-up10.1093/annonc/mdx222 ↗
47. A method to measure the hyperelastic parameters of ex vivo breast tissue samples10.1088/0031-9155/49/18/014 ↗
48. Finite-element modeling of soft tissue rolling indentation10.1109/TBME.2011.2106783 ↗
49. Calculating the elastic modulus from instrumented indentation reload curves
50. Smith · 2010
51. Elastography in the assessment of sentinel lymph nodes prior to dissection10.1016/j.ejrad.2012.04.031 ↗
52. Magnetic resonance elastography of liver: technique, analysis, and clinical applications10.1002/jmri.23731 ↗
53. Vilmann · Endoscopy · 2015 · 47 · 54510.1055/s-0034-1392040 ↗
54. Mechanical characterization of porcine liver properties for computational simulation of indentation on cancerous tissue10.1093/imammb/dqaa006 ↗
55. In-vitro strain and modulus measurements in porcine cervical lymph nodes10.2174/1874120701105010039 ↗
56. Evaluation of material properties of incompressible hyperelastic materials based on instrumented indentation of an equal-biaxial prestretched substrate10.1016/j.ijsolstr.2015.03.019 ↗