Anatomically and mechanically conforming patient-specific spinal fusion cages designed by full-scale topology optimization
Source abstract
Abstract
Cage subsidence after instrumented lumbar spinal fusion surgery remains a significant cause of treatment failure, specifically for posterior or transforaminal lumbar interbody fusion. Recent advancements in computational techniques and additive manufacturing, have enabled the development of patient-specific implants and implant optimization to specific functional targets. This study aimed to introduce a novel full-scale topology optimization formulation that takes the structural response of the adjacent bone structures into account in the optimization process. The formulation includes maximum and minimum principal strain constraints that lower strain concentrations in the adjacent vertebrae. This optimization approach resulted in anatomically and mechanically conforming spinal fusion cages. Subsidence risk was quantified in a commercial finite element solver for off-the-shelf, anatomically conforming and the optimized cages, in two representative patients. We demonstrated that the anatomically and mechanically conforming cages reduced subsidence risk by 91% compared to an off-the-shelf implant with the same footprint for a patient with normal bone quality and 54% for a patient with osteopenia. Prototypes of the optimized cage were additively manufactured and mechanically tested to evaluate the manufacturability and integrity of the design and to validate the finite element model. • A novel full-scale topology optimization formulation tailored for patient-specific spinal fusion cages. • The optimized patient-specific spinal fusion cages result in anatomically and mechanically conforming devices. • Anatomically and mechanically conforming devises reduce subsidence risk compared to other cages. • The reduction in subsidence risk is 91% compared to an off-the-shelf implant for a patient with normal bone quality.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Topology Optimization in Engineering · Composite Material Mechanics · Manufacturing Process and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (56)
Show source-provided references
1. Giga-voxel computational morphogenesis for structural design10.1038/nature23911 ↗
2. Outcomes of surgical reconstruction using custom 3D-printed porous titanium implants for critical-sized bone defects of the foot and ankle10.1177/10711007221077113 ↗
3. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
4. Bergmann · 2008
5. Frictional and bone ingrowth properties of engineered surface topographies produced by electron beam technology10.1007/s00402-010-1218-9 ↗
6. 3D-printed spine surgery implants: a systematic review of the efficacy and clinical safety profile of patient-specific and off-the-shelf devices10.1007/s00586-019-06236-2 ↗
7. Interbody spacer material properties and design conformity for reducing subsidence during lumbar interbody fusion10.1115/1.4036312 ↗
8. Physics-informed machine learning for reduced-order modeling of nonlinear problems10.1016/j.jcp.2021.110666 ↗
9. Evaluation of the contact surface between vertebral endplate and 3D printed patient-specific cage vs commercial cage10.1038/s41598-022-16895-9 ↗
10. Empirical relationships between bone density and ultimate strength: a literature review
11. Clinical and radiographic outcomes of transforaminal lumbar interbody fusion in patients with osteoporosis10.1055/s-0036-1578804 ↗
12. Limiting the first principal stress in topology optimization: a local and consistent approach10.1007/s00158-022-03320-y ↗
13. OpenPNM: a pore network modeling package10.1109/MCSE.2016.49 ↗
14. PoreSpy: a Python toolkit for quantitative analysis of porous media images10.21105/joss.01296 ↗
15. Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements10.1016/j.jmbbm.2016.10.002 ↗
16. Lumbar spinal loads vary with body height and weight10.1016/j.medengphy.2012.09.009 ↗
17. S. J. Hollister, “INTERGRATED GLOBAL LAYOUT AND LOCAL MICROSTRUCTURE TOPOLOGY OPTIMIZATION APPROACH FOR SPINAL CAGE DESIGN AND FABRICATION.”.
18. Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization10.18063/ijb.697 ↗
19. Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone density10.1007/s005860050043 ↗
20. Heterogeneity and spatial distribution of intravertebral trabecular bone mineral density in the lumbar spine is associated with prevalent vertebral fracture10.1002/jbmr.3946 ↗
21. Maximum length scale in density based topology optimization10.1016/j.cma.2017.02.018 ↗
22. Comparison of outcomes of anterior, posterior, and transforaminal lumbar interbody fusion surgery at a single lumbar level with degenerative spinal disease10.1016/j.wneu.2017.01.114 ↗
23. Phantomless calibration of CT scans for measurement of BMD and bone strength—inter-operator reanalysis precision10.1016/j.bone.2017.07.029 ↗
24. Interbody fusion cage design using integrated global layout and local microstructure topology optimization10.1097/01.BRS.0000134573.14150.1A ↗
25. The design of simpleITK
26. Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density10.1302/0301-620X.80B2.0800351 ↗
27. Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF/ATP, LLIF and ALIF
28. Anterior lumbar interbody fusion using a personalized approach: is custom the future of implants for anterior lumbar interbody fusion surgery?10.1016/j.wneu.2018.12.144 ↗
29. Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence10.1016/j.jmbbm.2018.05.040 ↗
30. Titanium-based biomaterials for preventing stress shielding between implant devices and bone10.1155/2011/836587 ↗
31. Microstructure and mechanical properties of Titanium grade 23 produced by selective laser melting10.1007/s43452-021-00304-5 ↗
32. Density and mechanical properties of vertebral trabecular bone—a review10.1002/jsp2.1176 ↗
33. Biomechanical characteristics of human trabecular bone10.1016/S0268-0033(97)00035-1 ↗
34. Parisien · 2021
35. Subsidence of spinal fusion cages: a systematic review10.14444/8363 ↗
36. Interactive graph-cut segmentation for fast creation of finite element models from clinical ct data for hip fracture prediction10.1080/10255842.2016.1181173 ↗
37. Mechanical performance of lumbar intervertebral body fusion devices: an analysis of data submitted to the Food and Drug Administration10.1016/j.jbiomech.2018.07.022 ↗
38. Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month10.1016/j.clinbiomech.2007.09.011 ↗
39. Applying a follower load delivers realistic results for simulating standing10.1016/j.jbiomech.2009.03.048 ↗
40. Activities of everyday life with high spinal loads10.1371/journal.pone.0098510 ↗
41. The visualization toolkit: an object oriented approach to 3D graphics, 3rd edition - kitware Inc.pdf
42. Sigmund · 2004
43. Topology optimization using PETSc: a Python wrapper and extended functionality10.1007/s00158-021-03018-7 ↗
44. Conceptual design of compliant bone scaffolds by full-scale topology optimization
45. The effectiveness of percutaneous vertebroplasty is determined by the patient-specific bone condition and the treatment strategy
46. A lattice topology optimization of cervical interbody fusion cage and finite element comparison with ZK60 and Ti-6Al-4V cages10.1186/s12891-020-03840-y ↗
47. The method of moving asymptotes—a new method for structural optimization10.1002/nme.1620240207 ↗
48. Manufacturing and stiffness constraints for topology optimized periodic structures10.1007/s00158-022-03222-z ↗
49. Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion10.3171/2017.5.SPINE16427 ↗
50. Simple and efficient GPU accelerated topology optimisation: codes and applications10.1016/j.cma.2023.116043 ↗
51. Wang · 2011 · 767
52. On projection methods, convergence and robust formulations in topology optimization10.1007/s00158-010-0602-y ↗
53. Porous fusion cage design via integrated global-local topology optimization and biomechanical analysis of performance
54. Interbody fusion cage design driven by topology optimization10.1016/j.wneu.2022.08.108 ↗
55. Infill optimization for additive manufacturing-approaching bone-like porous structures10.1109/TVCG.2017.2655523 ↗
56. Biomechanical analysis of porous additive manufactured cages for lateral lumbar interbody fusion: a finite element analysis10.1016/j.wneu.2017.12.127 ↗