journal article·2012-04

What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?

Mathew T. Mathew, Valentim A. Barão, Judy Chia-Chun Yuan, Wirley G. Assunção, Cortino Sukotjo, Markus A. Wimmer

Publisher page

Abstract

In an oral environment, titanium dental implants are exposed to a complex degradation process which is predominantly influenced by the intermittent mechanical events (mastication), continuous exposure to varying chemical solutions (saliva and food) and formation of microbiological (biofilm). Several studies have investigated the chemical corrosion and mechanical resistance of titanium; however, very few attempted to report on the effects of combined chemical, mechanical and microbiological interactions, which simulates the oral environment. A new multi-disciplinary research area, "tribocorrosion" (a combined study of wear and corrosion), was used to address such issues. The tribocorrosive nature of titanium in artificial saliva (pH 6.5) with lipopolysaccharide (LPS) was investigated. Twenty-four titanium discs (12 mm diameter, 7 mm thickness), were divided into 8 groups (n=3) as a function of material (commercially pure titanium (cpTi) and titanium-aluminum-vanadium (TiAlV) alloy) and LPS concentrations (0, 0.15, 15 and 150 μg/ml). Sliding duration (2000 cycles), frequency (1.2 Hz) and load (20 N) parameters mimicked the daily mastication process. Electrochemical impedance spectroscopy was conducted before and after tribocorrosion to comprehend the changes in corrosion kinetics. Worn surfaces were examined using white-light-interferometry and scanning electron microscopy. Total weight loss and roughness values were calculated. LPS affected the tribocorrosive behavior of both titanium types. LPS statistically accelerated the ion exchange between titanium and saliva, and reduced the resistance of the titanium surface against corrosion (p<.05). Sliding events decreased the protectiveness of the titanium surface. In general, TiAlV exhibited better corrosion behavior, but both titanium types showed similar in total weight loss (p>.05). LPS significantly increased the cpTi weight loss (p=.041), and the roughness of the surface (p<.001). In summary, LPS negatively affected the corrosion/wear behavior of titanium, which may contribute to the failure of dental implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Ariza, E., Rocha, L.A., 2005. Evaluation of corrosion resistance of multi-layered Ti/glass-ceramic interfaces by electrochemical impedance spectroscopy. Functionally Graded Materials Viii 492-493, 189-194.10.4028/www.scientific.net/MSF.492-493.189 ↗
2. Tribo-electrochemical technique for studying tribocorrosion behavior of biomaterials10.1016/j.bioeng.2007.07.015 ↗
3. The role of lipopolysaccharide on the electrochemical behavior of titanium10.1177/0022034510396880 ↗
4. Barao, V.A., Mathew, M.T., Assuncao, W.G., Yuan, J.C., Wimmer, M.A., Sukotjo, C., 2011. Stability of cp-Ti and Ti–6Al-4 V alloy for dental implants as a function of saliva pH — an electrochemical study. Clin. Oral Implants Res., in press (doi:10.1111/j.1600-0501.2011.02265.x).
5. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4 V in 0.9 wt% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
6. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis10.1034/j.1600-0501.1996.070302.x ↗
7. An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications10.1007/s10856-008-3487-1 ↗
8. Levels of aggregatibacter actinomycetemcomitans, porphyromonas gingivalis, inflammatory cytokines and species-specific immunoglobulin G in generalized aggressive and chronic periodontitis10.1111/j.1600-0765.2010.01278.x ↗
9. An overview of the corrosion aspect of dental implants (titanium and its alloys)10.4103/0970-9290.49068 ↗
10. Fatigue and fluoride corrosion on Streptococcus mutans adherence to titanium-based implant/component surfaces10.1111/j.1532-849X.2009.00463.x ↗
11. Galvanic corrosion behavior of titanium implants coupled to dental alloys10.1023/A:1008905229522 ↗
12. The effect of surface treatments on the fretting behavior of Ti–6Al-4 V alloy10.1002/jbm.b.31034 ↗
13. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
14. In vitro corrosion behavior of bioceramic, metallic, and bioceramic–metallic coated stainless steel dental implants10.1016/S0109-5641(02)00029-5 ↗
15. Tribocorrosion behaviour of plasma nitrided and plasma nitrided plus oxidised Ti6A14 V alloy10.1016/j.surfcoat.2005.11.069 ↗
16. Clinical experiences with dental implants10.1177/08959374990130010401 ↗
17. Analysis of early biofilm formation on oral implants in man10.1111/j.1365-2842.2007.01725.x ↗
18. Electrochemical corrosion properties of Ti–6Al-4V implant alloy in the biological environment10.1016/j.msea.2004.03.069 ↗
19. Effect of fluoride and albumin concentration on the corrosion behavior of Ti–6Al-4 V alloy10.1016/S0142-9612(02)00315-0 ↗
20. Teeth and bones: applications of surface science to dental materials and related biomaterials10.1016/S0167-5729(00)00011-X ↗
21. Corrosion behaviour of titanium after short-term exposure to an acidic environment containing fluoride ions10.1007/s10856-009-3930-y ↗
22. Corrosion behaviour of TiN and ZrN in the environment containing fluoride ions10.1088/1748-6041/5/5/054108 ↗
23. Effect of pH on Porphyromonas gingivalis endotoxin affinity for resins
24. The corrosion/wear mechanisms of Ti–6Al-4 V alloy for different scratching rates10.1016/j.wear.2006.11.025 ↗
25. Electrochemical methods in tribocorrosion: a critical appraisal10.1016/S0013-4686(01)00679-X ↗
26. Effect of load deflection on corrosion behavior of NiTi wire10.1177/154405910708600610 ↗
27. Biodegradation of restorative metallic systems10.1177/08959374920060011301 ↗
28. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium10.1016/j.actbio.2005.09.004 ↗
29. Comparative corrosion study of Ti-Ta alloys for dental applications10.1016/j.actbio.2009.05.037 ↗
30. Tribocorrosion behaviour of TiCxOy thin films in bio-fluids10.1016/j.electacta.2010.08.067 ↗
31. Mathew, M.T., Srinivasa Pai, P., Pourzal, R., Fischer, A., Wimmer, M.A., 2009. Significance of tribocorrosion in biomedical applications: overview and current status. Adv. in Tribology 2009, Article ID 250986, 250912 pages.10.1155/2009/250986 ↗
32. Corrosion of phosphate-enriched titanium oxide surface dental implants (TiUnite) under in vitro inflammatory and hyperglycemic conditions10.1002/jbm.b.31548 ↗
33. Corrosion of machined titanium dental implants under inflammatory conditions10.1002/jbm.b.31162 ↗
34. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
35. Wear-accelerated corrosion of passive metals in tribocorrosion systems10.1149/1.1838341 ↗
36. Biomaterial interface investigated by electrochemical impedance spectroscopy10.1002/adem.200800184 ↗
37. The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermentor10.1046/j.1365-2672.2001.01338.x ↗
38. Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use10.1177/00220345990780091201 ↗
39. Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys10.4012/dmj.21.83 ↗
40. Lipopolysaccharide affinity for titanium implant biomaterials10.1016/S0022-3913(97)70210-5 ↗
41. Saliva and dental implants10.1097/01.id.0000239320.57403.8d ↗
42. Long-term assessment of the implant titanium material–artificial saliva interface10.1007/s10856-007-3271-7 ↗
43. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys10.1016/S0142-9612(01)00328-3 ↗
44. The role of endotoxin in periodontal disease. I. A reproducible, quantitative method for determining the amount of endotoxin in human gingival exudate
45. Micro-abrasion-corrosion of a CoCrMo alloy in simulated artificial hip joint environments10.1016/j.wear.2005.02.045 ↗
46. Biofilms inducing ultra-low friction on titanium10.1177/0022034510378428 ↗
47. Do oral biofilms influence the wear and corrosion behavior of titanium?10.1080/08927011003767985 ↗
48. Effects of pH on the electrochemical behaviour of titanium alloys for implant applications10.1007/s10856-008-3623-y ↗
49. Mapping erosion-corrosion of carbon steel in oil exploration conditions: Some new approaches to characterizing mechanisms and synergies10.1016/j.triboint.2010.01.005 ↗
50. Increase of endotoxin concentration in gingival washings during experimental gingivitis in man10.1902/jop.1979.50.4.175 ↗
51. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids10.1016/j.corsci.2008.04.002 ↗
52. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
53. Biological activities of lipopolysaccharides from oral bacteria and their relevance to the pathogenesis of chronic periodontitis
54. Corrosion behavior of Ti–5Ag alloy with and without thermal oxidation in artificial saliva solution10.1016/j.dental.2010.10.005 ↗