Abstract
Secondary interventions after endovascular repair of abdominal aortic aneurysms are frequent because stent-graft (SG) related complications may occur (mainly endoleak and SG thrombosis). Complications have been related to insufficient SG flexibility, especially when devices are deployed in tortuous arteries. Little is known on the relationship between SG design and flexibility. Therefore, the aim of this study was to simulate numerically the bending of two manufactured SGs (Aorfix--Lombard Medical (A) and Zenith--Cook Medical Europe (Z)) using finite element analysis (FEA). Global SG behavior was studied by assessing stent spacing variation and cross-section deformation. Four criteria were defined to compare flexibility of SGs: maximal luminal reduction rate, torque required for bending, maximal membrane strains in graft and maximal Von Mises stress in stents. For angulation greater than 60°, values of these four criteria were lower with A-SG, compared to Z-SG. In conclusion, A-SG was more flexible than Z-SG according to FEA. A-SG may decrease the incidence of complications in the setting of tortuous aorto-iliac aneurysms. Our numerical model could be used to assess flexibility of further manufactured as well as newly designed SGs.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Vascular Procedures and Complications · Cardiac, Anesthesia and Surgical Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: a study using a flow model10.1053/ejvs.2001.1385 ↗
2. Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European multicenter experience
3. Finite-element analysis of a stenotic artery revascularization through a stent insertion
4. The advantages of Aorfix (TM) for endovascular repair of abdominal aortic aneurysm
5. Endoleaks after endovascular repair of abdominal aortic aneurysms10.1097/01.RVI.0000085773.71254.86 ↗
6. Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes10.1016/S0741-5214(02)00117-9 ↗
7. Influence of the textile structure on the degradation of explanted aortic endoprostheses10.1016/S1078-5884(03)00341-1 ↗
8. Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence10.1016/j.ejvs.2007.01.009 ↗
9. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial10.1016/S0140-6736(04)16979-1 ↗
10. Endovascular versus open repair of abdominal aortic aneurysm10.1056/NEJMoa0909305 ↗
11. Textile heart valve prosthesis: the effect of fabric construction parameters on long-term durability10.1177/0040517507101457 ↗
12. Early results of a flexible bifurcated endovascular stent-graft (Aorfix)
13. Comparison of implicit and explicit finite-element methods for the hydroforming process of an automobile lower arm10.1007/s001700200170 ↗
14. Computational mechanics of Nitinol stent grafts10.1016/j.jbiomech.2008.05.032 ↗
15. Non symmetric tension compression behaviour of NiTi alloy
16. Stress-induced martensitic transformation of Niti alloy in isothermal shear, tension, and compression10.1016/S1359-6454(98)00167-0 ↗
17. Fatigue and durability of Nitinol stents10.1016/j.jmbbm.2007.08.001 ↗
18. The Aorfix stent-graft to treat infrarenal abdominal aortic aneurysms with angulated necks and/or tortuous iliac arteries: midterm results10.1583/09-2822.1 ↗
19. Anaconda aortic stent-graft: single-center experience of a new commercially available device for abdominal aortic aneurysms10.1583/07-2277.1 ↗
20. Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: a 4-year single-center follow-up10.1583/1074-6218(1999)006<0017:TRAISP>2.0.CO;2 ↗
21. First report of a late type III endoleak from fabric tears of a Zenith stent graft10.1016/j.jvs.2008.03.047 ↗
22. Use of the Aorfix (TM) stent graft in patients with tortuous iliac anatomy
23. Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome10.1016/j.jvs.2004.03.008 ↗