Biomechanical properties of an intact, injured, repaired, and healed femur: An experimental and computational study
Source abstract
Abstract
There is no "gold standard" treatment for femoral mid-shaft fractures near the tip of a hip implant. Moreover, no study has quantified the changes in a femur's mechanical properties from injury through to healing. The present aim was to predict overall stiffness and peak bone stress in the same femur after injury, repair, and healing with respect to its intact condition. Stage 1 was an intact femur. Stage 2 mimicked a femur with a hip stem. Stage 3 had a 5-mm fracture gap repaired with a plate and screws. Stage 4 represented complete fracture union. Experiments were done on a synthetic femur with strain gages and subjected to 1500 N of axial force. Finite element (FE) models were validated against experiments and then re-analyzed using a clinical-level force of 3000 N. At 1500 N, FE vs. experimental strains had excellent linear agreement (R=0.94; slope=0.97). At 3000 N, FE stiffnesses were 2167 N/mm (Stage 1), 2359 N/mm (Stage 2), 973 N/mm (Stage 3), and 3348 N/mm (Stage 4), showing that Stage 3 was the least stable compared to Stage 1. At 3000 N, FE bone stresses yielded peaks of 75.7 MPa at the load application point (Stage 1), 29.0 MPa near the hip implant tip (Stage 2), 126.3 MPa at the distal portion of the plate (Stage 3), and 69.3 MPa at the proximal portion of the plate (Stage 4), showing that Stage 3 was most vulnerable to re-injury compared to Stage 1. Stress shielding and high stresses were present not only after hip implantation and plating, but also after healing.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Hip and Femur Fractures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (94)
Show source-provided references
1. AISI Type 316L Stainless Steel, Annealed Plate, 〈http://www.matweb.com〉.
2. ASTM International(a), West Conshohocken, PA, USA, ASTM D638-10, Standard Test Method for Tensile Properties of Plastics. 〈http://www.astm.org/Standards/D638.htm〉.
3. ASTM International(b), West Conshohocken, PA, USA, ASTM F75-07, Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants. 〈http://www.astm.org/Standards/F75.htm〉.
4. ASTM International(c), West Conshohocken, PA, USA, ASTM F1472, Standard Specification for Wrought Titanium-6 Aluminum-4 Vanadium Alloy for Surgical Implant Applications. 〈http://www.astm.org/Standards/F1472.htm〉.
5. The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures10.1115/1.4005696 ↗
6. Periprosthetic fractures of the femur. Analysis of 93 fractures10.1097/00003086-199606000-00029 ↗
7. Evaluation of bone plate with low-stiffness material in terms of stress distribution10.1016/j.jbiomech.2008.08.003 ↗
8. Hip joint loading during walking and running, measure in two patients10.1016/0021-9290(93)90058-M ↗
9. The use of Dall-Miles cables in total hip arthroplasty10.3928/0147-7447-19930701-16 ↗
10. Proximal femoral fractures following total hip arthroplasty10.1097/00003086-198210000-00013 ↗
11. The effect of muscle loading on the simulation of bone remodeling in the proximal femur10.1016/j.jbiomech.2004.03.005 ↗
12. The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis10.1243/09544119JEIM501 ↗
13. Bone remodeling in a new biomimetic polymer-composite hip stem10.1002/jbm.a.32346 ↗
14. The Biomechanics of a validated finite element model of stress shielding in a novel Hybrid total knee replacement10.1243/09544119JEIM691 ↗
15. Assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements10.1186/1749-799X-5-34 ↗
16. A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements10.1115/1.4004414 ↗
17. A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants10.1016/j.medengphy.2010.09.011 ↗
18. The Vancouver classification of periprosthetic fractures of the hip: a rational approach to treatment10.1097/00013611-199906000-00005 ↗
19. Classification of the hip10.1016/S0030-5898(05)70076-6 ↗
20. The reliability and validity of the Vancouver classification of femoral fractures after total hip replacement10.1016/S0883-5403(00)91181-1 ↗
21. The use of cortical allograft struts for fixation of fractures associated with well-fixed total joint prostheses
22. Diaphyseal fractures of the femur
23. Three-dimensional finite element analysis of a simplified compression plate fixation system10.1115/1.3138497 ↗
24. Stress analysis of compression plate fixation and its effects on long bone remodeling10.1016/0021-9290(85)90006-5 ↗
25. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty10.1002/jor.1100100314 ↗
26. Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading10.1016/j.medengphy.2003.10.006 ↗
27. Influence of size and stability of the osteotomy gap on the success of fracture healing10.1002/jor.1100150414 ↗
28. Effects of mechanical factors on the fracture healing process10.1097/00003086-199810001-00015 ↗
29. Fractures of the femur in relation to cemented hip prostheses
30. Mechanical validation of whole bone composite femur models10.1016/0021-9290(95)00084-4 ↗
31. Femoral neck fracture following hip resurfacing: the effect of alignment of the femoral component
32. Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems10.1016/j.clinbiomech.2005.12.011 ↗
33. Fixation of periprosthetic femoral fracture shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques10.1054/arth.2000.4339 ↗
34. Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques10.1097/00005131-200103000-00005 ↗
35. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position10.1177/0954411911410642 ↗
36. Influence of muscle forces on femoral strain distribution10.1016/S0021-9290(98)00080-3 ↗
37. Fractures of the femur after total hip replacement
38. Elstrom · 2006
39. Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty. A basic science and clinical study10.1097/00003086-199212000-00007 ↗
40. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates10.1097/01.bot.0000199119.38359.96 ↗
41. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates10.1186/1475-925X-4-46 ↗
42. The influence of induced micromovement upon the healing of experimental tibial fractures
43. Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening10.1097/00003086-197906000-00002 ↗
44. Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate
45. Clinical and roentgenographic evaluation of noncemented porous-coated anatomic medullary locking (AML) and porous-coated anatomic (PCA) total hip arthroplasties10.1097/00003086-199009000-00022 ↗
46. Structural properties of a new design of composite replicate femurs and tibias10.1016/S0021-9290(01)00015-X ↗
47. Biomechanics of bone
48. Jimenez, M.L., Sferra, T.A., and Twigg, S.L. Morbidity and mortality associated with periprosthetic fractures of the femur. Orthopaedic Trauma Association 20th Annual Meeting. Florida, Oct 8–10, 2004, paper no. 63.
49. Fracture of the ipsilateral femur in patients with total hip replacement
50. Bone-ingrowth hip prostheses in asymptomatic patients: radiographic features10.1148/radiology.169.1.3420262 ↗
51. Controlled mechanical stimulation in the treatment of tibial fractures10.1097/00003086-198904000-00006 ↗
52. Axial movement and tibial fractures—a controlled randomized trial of treatment
53. Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: biomechanical comparison studies on cadaveric bones10.1016/j.injury.2010.05.007 ↗
54. Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis
55. Femoral strain changes after total hip arthroplasty—patient-specific finite element analyses 12 years after operation10.1016/j.medengphy.2004.12.016 ↗
56. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support
57. Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures10.1097/BOT.0b013e31815c89ce ↗
58. The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty10.1186/1749-799X-5-45 ↗
59. Periprosthetic femur fractures: a complication of rigid cylindrical reaming?
60. The biomechanics of ipsilateral intertrochanteric and femoral shaft fractures: a comparison of 5 fracture fixation techniques10.1097/BOT.0b013e31817d97bc ↗
61. Methods of operative fixation of the acromio-clavicular joint: a biomechanical comparison10.1097/BOT.0b013e31803eb14e ↗
62. Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty10.1016/0021-9290(92)90087-H ↗
63. The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour,10.1177/0954411911420004 ↗
64. Fractures beneath hip prostheses: a special indication for parham bands and plating
65. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs10.1115/1.2401178 ↗
66. Nylon straps for internal fixation of bone10.1016/S0140-6736(76)91187-9 ↗
67. Fixation of periprosthetic femur fractures: a biomechanical analysis comparing cortical strut allograft plates and conventional metal plates10.3928/0147-7447-20030701-13 ↗
68. Distal cortical hypertrophy following total hip arthroplasty10.1016/S0883-5403(88)80076-7 ↗
69. Sanders · 2008
70. Sawbones, Vashon, WA, USA, 〈www.sawbones.com/catalog/pdf/us_catalog.pdf〉.
71. Surgical management of intra and post operative fractures of the femur about the tip of the stem in total hip arthroplasty10.1016/S0883-5403(96)80010-6 ↗
72. Femoral fractures in conjunction with total hip replacement
73. Treatment of fractures about hip prostheses with compression plating10.1016/0883-5403(92)90005-B ↗
74. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?10.1177/0954411911413060 ↗
75. Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages
76. A biomechanical study of three wiring techniques for cerclage-plating10.1097/00005131-199505000-00004 ↗
77. Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction10.1016/S0021-9290(00)00225-6 ↗
78. Dall-Miles plating for periprosthetic B1 fractures of the femur10.1016/S0883-5403(00)91129-X ↗
79. Cyclic loading of periprosthetic fracture fixation constructs
80. Fixation of long bone segmental defects: a biomechanical study10.1016/j.injury.2007.08.026 ↗
81. Fractures of the femur after hip replacement: the Oregon experience10.1016/S0030-5898(05)70078-X ↗
82. Dall-Miles plates for periprothetic femoral fractures. A critical review of 16 cases10.1016/S0020-1383(02)00161-4 ↗
83. The management of periprosthetic femoral fractures around hip replacements10.1016/S0020-1383(02)00257-7 ↗
84. US Department of Transportation, Transportation Statistics Annual Report 2007, Washington, DC, USA, 2007, 〈www.bts.gov〉.
85. Periprosthetic fractures: an operative algorithm10.3928/0147-7447-20010901-19 ↗
86. A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures10.1016/j.clinbiomech.2004.08.008 ↗
87. The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation10.1016/S0268-0033(98)00097-7 ↗
88. Thermoelastic stress analysis by means of a standard thermocamera
89. Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs10.1115/1.2540926 ↗
90. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis10.1243/09544119JEIM409 ↗
91. Biomechanical evaluation of periprosthetic femoral fracture fixation
92. Cortical screw purchase in synthetic and human femurs10.1115/1.3194755 ↗
93. The effect of cortex thickness on intact femur biomechanics: a comparison of finite element analysis with synthetic femurs10.1243/09544119JEIM702 ↗
94. Ogden plate and other fixations for fractures complicating femoral endoprostheses10.1097/00003086-198806000-00010 ↗