Extracting accurate strain measurements in bone mechanics: A critical review of current methods
Source abstract
Abstract
Osteoporosis related fractures are a social burden that advocates for more accurate fracture prediction methods. Mechanistic methods, e.g. finite element models, have been proposed as a tool to better predict bone mechanical behaviour and strength. However, there is little consensus about the optimal constitutive law to describe bone as a material. Extracting reliable and relevant strain data from experimental tests is of fundamental importance to better understand bone mechanical properties, and to validate numerical models. Several techniques have been used to measure strain in experimental mechanics, with substantial differences in terms of accuracy, precision, time- and length-scale. Each technique presents upsides and downsides that must be carefully evaluated when designing the experiment. Moreover, additional complexities are often encountered when applying such strain measurement techniques to bone, due to its complex composite structure. This review of literature examined the four most commonly adopted methods for strain measurements (strain gauges, fibre Bragg grating sensors, digital image correlation, and digital volume correlation), with a focus on studies with bone as a substrate material, at the organ and tissue level. For each of them the working principles, a summary of the main applications to bone mechanics at the organ- and tissue-level, and a list of pros and cons are provided.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Optical measurement and interference techniques · Ultrasonics and Acoustic Wave Propagation · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (65)
Show source-provided references
1. Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems10.1302/0301-620X.83B6.0830921 ↗
2. Local reinforcement effect of embedded strain gauges10.1051/epjconf/20100613003 ↗
3. Assessment of digital image correlation measurement accuracy in the ultimate error regime: main results of a collaborative benchmark10.1111/str.12054 ↗
4. An Y., Draughn R., Mechanical Testing of Bone and the Bone–Implant Interface, 1999.10.1201/9781420073560 ↗
5. Verification, validation and sensitivity studies in computational biomechanics10.1080/10255840601160484 ↗
6. Automatic segmentation of medical images using image registration: diagnostic and simulation applications10.1080/03091900412331289889 ↗
7. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures10.1016/j.jbiomech.2014.10.025 ↗
8. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
9. Numerical analysis of the reinforcement effect of a strain gage applied to a soft material10.1016/0020-7225(79)90019-3 ↗
10. Experimental methods of stress and strain analysis in orthopaedics biomechanics
11. Prediction of the fracture load of whole proximal femur specimens by topological analysis of the mineral distribution in DXA-scan images10.1016/j.bone.2008.07.244 ↗
12. Assessment of digital image correlation measurement errors: methodology and results10.1007/s11340-008-9204-7 ↗
13. Femoral strength is better predicted by finite element models than QCT and DXA10.1016/S0021-9290(99)00099-8 ↗
14. Strain distribution in the proximal human femoral metaphysis10.1243/09544119JEIM497 ↗
15. Mechanical testing of bones: the positive synergy of finite-element models and in vitro experiments
16. Multiscale investigation of the functional properties of the human femur
17. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
18. Reliability and accuracy of embedded fiber Bragg grating sensors for strain monitoring in advanced composite structures10.1007/s12540-014-3020-7 ↗
19. Age variations in the properties of human tibial trabecular bone10.1302/0301-620X.79B6.0790995 ↗
20. Fibre optic Bragg grating sensors: an alternative method to strain gauges for measuring deformation in bone10.1016/j.medengphy.2007.01.006 ↗
21. A critical review of the biomechanical stress analysis of the human femur10.1016/0142-9612(82)90053-9 ↗
22. Development of an inertia-driven model of sideways fall for detailed study of femur fracture mechanics10.1115/1.4025390 ↗
23. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
24. Experimental validation of finite element model for proximal composite femur using optical measurements10.1016/j.jmbbm.2013.02.006 ↗
25. Full-field strain measurement during mechanical testing of the human femur at physiologically relevant strain rates10.1115/1.4028415 ↗
26. Mechanism of head injury as studies by the cathode ray oscilloscope preliminary report10.3171/jns.1944.1.6.0393 ↗
27. Development of a balanced experimental-computational approach to understanding the mechanics of proximal femur fractures10.1016/j.medengphy.2014.02.019 ↗
28. Mathematical relationships between bone density and mechanical properties: a literature review10.1016/j.clinbiomech.2007.08.024 ↗
29. A survey of finite element analysis in orthopedic biomechanics: the first decade10.1016/0021-9290(83)90072-6 ↗
30. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
31. Strain distribution in the proximal human femur. An in vitro comparison in the intact femur and after insertion of reference and experimental femoral stems10.1302/0301-620X.83B2.0830295 ↗
32. Kleckers T., Fibre Bragg sensors compared with electrical strain gauges for use in force measurement – Prospects and potentials, in: Proceedings of the XIX IMEKO World Congress Fundamental and Applied Metrology, 2009.
33. Metrological characteristics of resistance strain gauges and evaluation of deformation measurement errors10.1007/BF00821043 ↗
34. Yield strain behavior of trabecular bone,10.1016/S0021-9290(98)00057-8 ↗
35. Kyowa Electronic Instruments, Strain gage catalogue, pp. 1–100, Available at 〈http://www.kyowa-ei.com/eng/download/technical/strain_gages/pdf_index_001_eng.pdf〉.
36. A practical approach to optimizing the preparation of speckle patterns for digital-image correlation10.1088/0957-0233/25/10/107001 ↗
37. Incidence of traumatic long-bone fractures requiring in-hospital management: a prospective age- and gender-specific analysis of 4890 fractures10.1016/j.injury.2009.06.003 ↗
38. Miles · 1992
39. A review of the biomechanical properties of bone as a material10.1016/0141-5425(89)90058-7 ↗
40. Fracture mechanisms in soft rock: identification and quantification of evolving displacement discontinuities by extended digital image correlation10.1016/j.tecto.2010.09.024 ↗
41. Validated finite element models of the proximal femur using two-dimensional projected geometry and bone density10.1016/j.cmpb.2010.11.008 ↗
42. An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems10.1302/0301-620X.91B5.21749 ↗
43. Ovryn B., 1993. Whole-field displacement and strain measurements: application to biomechanics In: Proceedings of the SPIE 1889, Holography, Interferometry, and Optical Pattern Recognition in Biomedicine III, pp. 134–148.10.1117/12.155711 ↗
44. 3D local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
45. Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review10.1088/0957-0233/20/6/062001 ↗
46. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions10.1016/j.medengphy.2005.06.003 ↗
47. Strain-gage reinforcement effects on orthotropic materials10.1111/j.1747-1567.1986.tb01386.x ↗
48. Digital imaging techniques in experimental stress analysis10.1117/12.7972925 ↗
49. Load measurement in orthopaedics using strain gauges10.1016/0141-5425(79)90168-7 ↗
50. Finite element models in tissue mechanics and orthopaedic implant design10.1016/S0268-0033(97)00018-1 ↗
51. Differences in external and internal cortical strain with prosthesis in the femur10.2174/1874325001105010379 ↗
52. A review on the application of the digital volume correlation technique for the measurement of displacement and strain fields in bone10.1016/j.jbiomech.2014.01.001 ↗
53. Strain-gage techniques in biomechanics10.1007/BF02326147 ↗
54. Biomechanical and molecular regulation of bone remodeling10.1146/annurev.bioeng.8.061505.095721 ↗
55. Digital image correlation and fracture: an advanced technique for estimating stress intensity factors of 2D and 3D cracks10.1088/0022-3727/42/21/214004 ↗
56. Determination of displacements using an improved digital correlation method10.1016/0262-8856(83)90064-1 ↗
57. Three-dimensional digital image correlation to quantify deformation and crack-opening displacement in ductile aluminum under mixed-mode I/III loading10.1117/1.2741279 ↗
58. Sutton · 2009
59. Shear deformation and fracture of human cortical bone10.1016/j.bone.2014.10.001 ↗
60. Extracting clinically relevant data from finite element simulations10.1016/j.clinbiomech.2005.01.010 ↗
61. Vishay Micro-Measurements, 2005. Surface preparation for strain gage bonding. Application Note B-129–8.
62. In silico models of bone remodeling from macro to nano – from organ to cell10.1002/wsbm.115 ↗
63. Werneck M., Allil R., RibeiroB., de Nazaré F., A Guide to Fiber Bragg Grating Sensors, pp. 1–24, 2013.
64. Strain distribution in the proximal Human femur during in vitro simulated sideways fall10.1016/j.jbiomech.2015.02.022 ↗
65. A review of morphology–elasticity relationships in human trabecular bone: theories and experiments10.1016/S0021-9290(03)00128-3 ↗