On the necessity of modelling fluid–structure interaction for stented coronary arteries
Source abstract
Abstract
Although stenting is the most commonly performed procedure for the treatment of coronary atherosclerotic lesions, in-stent restenosis (ISR) remains one of the most serious clinical complications. An important stimulus to ISR is the altered hemodynamics with abnormal shear stresses on endothelial cells generated by the stent presence. Computational fluid dynamics is a valid tool for studying the local hemodynamics of stented vessels, allowing the calculation of the wall shear stress (WSS), which is otherwise not directly possible to be measured in vivo. However, in these numerical simulations the arterial wall and the stent are considered rigid and fixed, an assumption that may influence the WSS and flow patterns. Therefore, the aim of this work is to perform fluid-structure interaction (FSI) analyses of a stented coronary artery in order to understand the effects of the wall compliance on the hemodynamic quantities. Two different materials are considered for the stent: cobalt-chromium (CoCr) and poly-l-lactide (PLLA). The results of the FSI and the corresponding rigid-wall models are compared, focusing in particular on the analysis of the WSS distribution. Results showed similar trends in terms of instantaneous and time-averaged WSS between compliant and rigid-wall cases. In particular, the difference of percentage area exposed to TAWSS lower than 0.4Pa between the CoCr FSI and the rigid-wall cases was about 1.5% while between the PLLA cases 1.0%. The results indicate that, for idealized models of a stented coronary artery, the rigid-wall assumption for fluid dynamic simulations appears adequate when the aim of the study is the analysis of near-wall quantities like WSS.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Cardiovascular Health and Disease Prevention · Rheology and Fluid Dynamics Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (81)
Show source-provided references
1. Discordance of the areas of peak wall shear stress and tissue stress in coronary artery plaques as revealed by fluid-structure interaction finite element analysis: a case study10.1536/ihj.54.54 ↗
2. Effects of different stent designs on local hemodynamics in stented arteries10.1016/j.jbiomech.2007.12.005 ↗
3. Bathe, K.J., 2006a. Theory and Modeling guide, vol. I: ADINA Solids & Structures, ADINA R&D, Inc., Watertown, MA, USA
4. Bathe K.J., 2006b. Theory and Modeling guide, vol. II: ADINA CFD & FSI, ADINA R&D, Inc., Watertown, MA, USA.
5. Finite element developments for general fluid flows with structural interactions10.1002/nme.959 ↗
6. Finite element analysis of fluid flows fully coupled with structural interactions10.1016/S0045-7949(99)00042-5 ↗
7. A numerical parametric study of the mechanical action of pulsatile blood flow onto axisymmetric stenosed arteries10.1016/j.medengphy.2012.02.010 ↗
8. Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation?10.1161/01.CIR.0000066914.95878.6D ↗
9. A piece-wise nonlinear elastic stress expression of human and pig coronary-arteries tested in vitro10.1016/0021-9290(91)90168-M ↗
10. Computational fluid dynamic simulations of image-based stented coronary bifurcation models10.1098/rsif.2013.0193 ↗
11. Fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method10.1016/j.euromechflu.2012.01.011 ↗
12. Evidence of dominant backward-propagating suction wave responsible for diastolic coronary filling in humans, attenuated in left ventricular hypertrophy10.1161/CIRCULATIONAHA.105.603050 ↗
13. Residual strain effects on the stress field in a thick wall finite element model of the human carotid bifurcation10.1016/S0021-9290(97)00025-0 ↗
14. A note on the elasticity of biological soft tissues10.1016/0021-9290(72)90047-4 ↗
15. An arbitrary Lagrangian–Eulerian finite element method for transient dynamic fluid-structure interaction10.1016/0045-7825(82)90128-1 ↗
16. Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro model
17. Optical coherence tomography for patient-specific 3D artery reconstruction and evaluation of wall shear stress in a left circumflex coronary artery10.1007/s13239-011-0047-5 ↗
18. A coupled momentum method for modeling blood flow in three-dimensional deformable arteries10.1016/j.cma.2005.11.011 ↗
19. Computer simulation of three-dimensional plaque formation and progression in the carotid artery10.1007/s11517-012-1031-4 ↗
20. Carotid arterial plaque stress analysis using fluid-structure interactive simulation based on in-vivo magnetic resonance images of four patients10.1016/j.jbiomech.2009.04.010 ↗
21. Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning10.1007/s10237-010-0196-8 ↗
22. Hyperelastic modeling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
23. Fluid-structure interaction in blood flows on geometries based on medical imaging10.1016/j.compstruc.2004.03.083 ↗
24. Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries10.1016/j.amjcard.2003.08.017 ↗
25. Computational fluid dynamics evaluation of equivalency in hemodynamic alterations between Driver, Integrity, and similar stents implanted into an idealized coronary artery10.1115/1.4023413 ↗
26. Optimization of cardiovascular stent design using computational fluid dynamics10.1115/1.4005542 ↗
27. Rapid and computationally inexpensive method to virtually implant current and next-generation stents into subject-specific computational fluid dynamics models10.1007/s10439-010-0238-5 ↗
28. A new technique for assessing arterial pressure wave forms and central pressure with tissue doppler10.1186/1476-7120-5-6 ↗
29. Effects of cyclic motion on coronary blood flow10.1115/1.4025335 ↗
30. Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia10.1016/0021-9290(96)00036-X ↗
31. Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling10.1152/ajpheart.00934.2004 ↗
32. Coronaryartery distensibility assessed by 3.0 Tesla coronary magnetic resonance imaging in subjects with and without coronary artery disease10.1016/j.amjcard.2011.03.078 ↗
33. Multiphysics simulation of blood flow and LDL transport in a porohyperelastic arterial wall model10.1115/1.2720914 ↗
34. Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries10.1152/ajpheart.01107.2004 ↗
35. A fluid-structure interaction analysis on hemodynamics in carotid artery based on patient-specific clinical data10.1007/s12206-012-1008-0 ↗
36. Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts10.1016/S0021-9290(01)00194-4 ↗
37. Fluid structure interaction of patient specific abdominal aortic aneurisms: a comparison with solid stress models10.1186/1475-925X-5-33 ↗
38. Hemodynamic shear stress and its role in atherosclerosis10.1001/jama.282.21.2035 ↗
39. Impedance-based outflow boundary conditions for human carotid haemodynamics10.1080/10255842.2012.744396 ↗
40. Blood flow and mass transfer of a human left coronary artery bifurcation: FSI vs. CFD10.1016/j.icheatmasstransfer.2012.04.009 ↗
41. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery10.1115/1.4005476 ↗
42. Reducing in-stent restenosis through novel stent flow field augmentation10.1007/s13239-012-0109-3 ↗
43. Predicting neointimal hyperplasia in stented arteries using time-dependant computational fluid dynamics: a review10.1016/j.compbiomed.2010.02.005 ↗
44. A numerical methodology to fully elucidate the altered wall shear stress in a stented coronary artery10.1007/s13239-010-0028-0 ↗
45. The influence of strut-connectors in stented vessels: a comparison of pulsatile flow through five coronary stents10.1007/s10439-010-9962-0 ↗
46. Relationship of shear stress with in-stent restenosis: bare metal stenting and the effect of brachytherapy10.1016/j.ijcard.2008.02.006 ↗
47. Coronary dilatation 10 weeks after paclitaxel-eluting stent implantation. No role of shear stress in lumen enlargement?10.1007/s00380-006-0970-9 ↗
48. In-stent neoatherosclerosis: a final common pathway of late stent failure10.1016/j.jacc.2011.10.909 ↗
49. Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model10.1016/0021-9290(95)95273-8 ↗
50. Reproducibility of quantitative measurements from intracoronary ultrasound images. beat-to-beat variability and influence of the cardiac cycle10.1093/oxfordjournals.eurheartj.a014726 ↗
51. Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model10.1016/j.jbiomech.2004.01.021 ↗
52. Fluid dynamic analysis in a human left anterior descending coronary artery with arterial motion10.1007/s10439-004-7816-3 ↗
53. Compound ex vivo and in silico method for hemodynamic analysis of stented arteries10.1371/journal.pone.0058147 ↗
54. Mechanical stresses in abdominal aortic aneurysm: influence of diameter, asymmetry and material anisotropy10.1115/1.2898830 ↗
55. Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics10.1157/13083645 ↗
56. Wall stress and flow dynamics in abdominal aortic aneurysms: Finite element analysis vs. fluid-structure interaction10.1080/10255840701827412 ↗
57. Compliant biomechanics of abdominal aortic aneurysms: a fluid-structure interaction study10.1016/j.compstruc.2006.08.041 ↗
58. Three-dimensional palpography of human coronary arteries: Ex vivo validation and in-patient evaluation
59. Spurk · 2008
60. A computational study of flow in a compliant carotid bifurcation-stress phase angle correlation with shear stress10.1007/s10439-005-5630-1 ↗
61. A comparative study based on patient-specific fluid-structure interaction modeling of cerebral aneurysms10.1115/1.4005071 ↗
62. Patient-specific arterial fluid-structure interaction modeling of cerebral aneurysms10.1002/fld.2360 ↗
63. A negative correlation between human carotid atherosclerotic plaque progression and plaque wall stress: In vivo MRI-based 2D/3D FSI models10.1016/j.jbiomech.2007.11.026 ↗
64. Effect of a lipid pool on stress/strain distributions in stenotic arteries: 3-D fluid-structure interactions (FSI) models10.1115/1.1762898 ↗
65. Steady flow and wall compression in stenotic arteries: a three-dimensional thick-wall model with fluid-wall interactions10.1115/1.1406036 ↗
66. A 3-D thin wall model with fluid-structure interactions for blood flow in carotid arteries with symmetric and asymmetric stenosis10.1016/S0045-7949(99)00019-X ↗
67. 3D critical plaque wall stress is a better predictor of carotid plaque rupture sites than flow shear stress: an in vivo MRI-based 3D FSI study10.1115/1.4001028 ↗
68. Modelling of fluid-structure interactions with the space-time finite elements: arterial fluid mechanics10.1002/fld.1443 ↗
69. Simulation of cardiac motion on non-Newtonian, pulsating flow development in the human left anterior descending coronary artery10.1088/0031-9155/53/18/002 ↗
70. Images in cardiovascular medicine. Focal in-stent restenosis near step-up: roles of low and oscillating shear stress?10.1161/01.CIR.0000018282.32332.13 ↗
71. Role of 0D peripheral vasculature model in fluid-structure interaction modeling of aneurysm10.1007/s00466-009-0439-7 ↗
72. Fluid-structure interaction modeling of aneurysmal conditions with high and normal blood pressures10.1007/s00466-006-0065-6 ↗
73. Fluid-structure interaction analysis of a patient-specific right coronary artery with physiological velocity and pressure waveforms10.1002/cnm.1231 ↗
74. Dynamic expansion of the coronary arteries: implications for intravascular ultrasound measurements10.1016/0002-8703(95)90234-1 ↗
75. Relationship between neointimal thickness and shear stress after wallstent implantation in human coronary arteries10.1161/01.CIR.103.13.1740 ↗
76. The influence of shear stress on in-stent restenosis and thrombosis
77. A patient-specific computational model of fluid–structure interaction in abdominal aortic aneurysms10.1016/j.medengphy.2005.06.008 ↗
78. Impact of flow rates in a cardiac cycle on correlations between advanced human carotid plaque progression and mechanical flow shear stress and plaque wall stress10.1186/1475-925X-10-61 ↗
79. Advanced human carotid plaque progression correlates positively with flow shear stress using follow-up scan data: an in vivo MRI multi-patient 3D FSI study10.1016/j.jbiomech.2010.05.018 ↗
80. In vivo IVUS-based 3-D fluid-structure interaction models with cyclic bending and anisotropic vessel properties for human atherosclerotic coronary plaque mechanical analysis10.1109/TBME.2009.2025658 ↗
81. Effects of cardiac motion on right coronary artery hemodynamics10.1114/1.1560631 ↗