The current study is part of an ongoing research program to develop an advanced new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite with a "sandwich structure" as a substitute for metallic materials for orthopedic long bone fracture plate applications. The purpose of this study was to assess the fatigue properties of this composite, since cyclic loading is one of the main types of loads carried by a femur fracture plate during normal daily activities. Conventional fatigue testing, thermographic analysis, and scanning electron microscopy (SEM) were used to analyze the damage progress that occurred during fatigue loading. Fatigue strength obtained using thermography analysis (51% of ultimate tensile strength) was confirmed using the conventional fatigue test (50-55% of ultimate tensile strength). The dynamic modulus (E(⁎)) was found to stay almost constant at 47GPa versus the number of cycles, which can be related to the contribution of both flax/epoxy and CF/epoxy laminae to the stiffness of the composite. SEM images showed solid bonding at the CF/epoxy and flax/epoxy laminae, with a crack density of only 0.48% for the plate loaded for 2 million cycles. The current composite plate showed much higher fatigue strength than the main loads experienced by a typical patient during cyclic activities; thus, it may be a potential candidate for bone fracture plate applications. Moreover, the fatigue strength from thermographic analysis was the same as that obtained by the conventional fatigue tests, thus demonstrating its potential use as an alternate tool to rapidly evaluate fatigue strength of composite biomaterials.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fatigue and fracture mechanics · Orthopaedic implants and arthroplasty · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (80)

Show source-provided references
1. ASTMD3479/D3479M-12, 2007. Standard test method for tension–tension fatigue of polymer matrix composite materials. American Society for Testing Materials.
2. ASTMF382, 2008. Standard specification and test method for metallic bone plates. Annual Book of ASTM Standards.
3. Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface10.1054/arth.2002.30285 ↗
4. Quantitative histological evaluation of early fracture healing of cortical bones immobilized by stainless steel and composite plates10.1007/BF02563988 ↗
5. Carbon fibre composite bone plates. Development, evaluation and early clinical experience10.1302/0301-620X.72B4.2380209 ↗
6. Influence of the stacking sequence on the mechanical properties of glass/sisal hybrid composites10.1177/0731684408096430 ↗
7. Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications10.1016/j.jmbbm.2012.12.013 ↗
8. Bagheri, Z.S., Elsawi, I., Amleh, A., Schemitsch, E.H., Zdero, R., Bougherara, H., 2013. New flax/epoxy and CF/epoxy composite materials for bone fracture plate applications: a biological and wettability study. ICCM 19. Montreal, Canada, July 28–August 2, pp. 8880–8889.
9. Biomechanics of a new CF/flax/epoxy plate versus a traditional metal plate for Vancouver B1 femur fractures: an experimental and computational study
10. Load bearing capacity of bone anchored fiber-reinforced composite device10.1007/s10856-007-3159-6 ↗
11. Bone tissue responses to glass fiber-reinforced composite implants—a histomorphometric study10.1111/j.1600-0501.2008.01700.x ↗
12. Prepolymerized vs. in situ-polymerized fiber-reinforced composite implants—a pilot study10.1177/0022034510384737 ↗
13. Histological changes associated with an artificial anterior cruciate ligament10.1136/jcp.48.6.556 ↗
14. Bartel · 2006
15. Design of a biomimetic polymer-composite hip prosthesis10.1002/jbm.a.31146 ↗
16. A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements10.1115/1.4004414 ↗
17. Carbon fibre reinforced epoxy as a high strength, low modulus material for internal fixation plates10.1016/0142-9612(80)90057-5 ↗
18. A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients10.1097/00007632-199310001-00030 ↗
19. Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial10.1097/00007632-200006010-00017 ↗
20. Characterization of short-fibre reinforced thermoplastics for fracture fixation devices10.1016/0142-9612(90)90075-2 ↗
21. Fatigue fracture of bone plates10.1016/S0020-1383(80)80044-1 ↗
22. Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering10.1243/09544119JEIM770 ↗
23. Compact bone fatigue damage—I. Residual strength and stiffness10.1016/0021-9290(77)90005-7 ↗
24. Mechanical properties of flax fibers and of the derived unidirectional composites10.1177/0021998310369579 ↗
25. Characterization of natural fibers and their application in bone grafting substitutes
26. Fatigue performance of composite analogue femur constructs under high activity loading10.1007/s10439-007-9284-z ↗
27. Development of a carbon–carbon hip prosthesis10.1002/j.1097-4636.1987.tb00018.x ↗
28. Fatigue behaviour of a GFRP laminate by thermographic measurements10.1016/j.proeng.2011.04.579 ↗
29. A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate
30. Dieter · 1986
31. Polymer-based composite hip prostheses10.1016/S0162-0134(99)00228-7 ↗
32. Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study10.1016/j.jmbbm.2012.09.005 ↗
33. Composite technology in load-bearing orthopaedic implants10.1016/S0142-9612(97)00217-2 ↗
34. Rapid determination of the fatigue curve by the thermographic method10.1016/S0142-1123(01)00107-4 ↗
35. Mechanical behavior of carbon/flax hybrid composites for structural applications10.1177/0021998311429884 ↗
36. Improved fracture healing with less rigid plates. A biomechanical study in dogs10.1097/00003086-199706000-00032 ↗
37. Performance study of braided carbon/PEEK composite compression bone plates10.1016/S0142-9612(03)00065-6 ↗
38. Feasibility of knitted carbon/PEEK composites for orthopedic bone plates10.1016/j.biomaterials.2003.10.050 ↗
39. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates10.1186/1475-925X-4-46 ↗
40. Polyetheretherketone (PEEK). Part I: prospects for use in orthopaedics and traumatology10.55095/achot2010/077 ↗
41. Carbon–carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris10.1023/B:JMSM.0000010102.26218.d1 ↗
42. Stiffness and strength design of composite bone plates10.1016/j.compscitech.2004.06.006 ↗
43. Inoue, H., Miyazaki, M., Saito, M., Toki, H., 1988. Sizing agent for carbon fibers. Google Patents.
44. Biological response to chopped-carbon-fiber-reinforced peek10.1002/jbm.820260202 ↗
45. Is routine implant removal after trauma surgery sensible?
46. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
47. Stiffness prediction of flax fibers-epoxy composite materials10.1023/A:1006776423764 ↗
48. Thermographic methodology for rapid determination of the fatigue limit of materials and mechanical components10.1016/S0142-1123(99)00088-2 ↗
49. Interfacial bonding of flax fibre/poly(l-lactide) bio-composites10.1016/j.compscitech.2009.10.009 ↗
50. The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty10.1186/1749-799X-5-45 ↗
51. A comparative study of fatigue behaviour of flax/epoxy and glass/epoxy composites10.1016/j.compscitech.2012.01.011 ↗
52. Hardware removal after fracture fixation procedures in the femur10.1097/TA.0b013e318219fea9 ↗
53. Infrared thermographic scanning of fatigue in metals10.1016/0029-5493(95)01043-H ↗
54. Fatigue limit evaluation of metals using an infrared thermographic technique10.1016/S0167-6636(97)00047-1 ↗
55. Use of infrared thermography to investigate the fatigue behavior of a carbon fiber reinforced polymer composite10.1016/j.compstruct.2012.09.046 ↗
56. Sisal/carbon fibre reinforced hybrid composites: tensile, flexural and chemical resistance properties10.1007/s10924-010-0210-3 ↗
57. Nordin · 2001
58. Carbon-fibre reinforced plates for problem fractures10.1302/0301-620X.74B1.1732273 ↗
59. Polyetheretherketone (PEEK). Part II: application in clinical practice10.55095/achot2010/078 ↗
60. Assessment of carbon fibre composite fracture fixation plate using finite element analysis10.1007/s10439-006-9102-z ↗
61. Repair of radial fractures in toy breed dogs with self-reinforced biodegradable bone plates, metal screws, and light-weight external coaptation10.1111/j.1532-950X.2005.00003.x ↗
62. Investigating the effect of machining processes on the mechanical behavior of composite plates with circular holes10.1016/j.compositesa.2013.09.002 ↗
63. An experimental investigation on the impact behavior of hybrid composite plates10.1016/j.compstruct.2009.10.036 ↗
64. Vertebral body replacement with a bioglass-polyurethane composite in spine metastases—clinical, radiological and biomechanical results10.1007/s005860000162 ↗
65. Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages10.1016/j.medengphy.2012.02.012 ↗
66. Composite technology for total hip arthroplasty10.1097/00003086-198810000-00022 ↗
67. Structural response and relative strength of a laminated composite hip prosthesis: effects of functional activity10.1016/S0142-9612(00)00053-3 ↗
68. Carbon fiber reinforced PEEK optima—a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
69. Carbon fiber reinforced PEEK optima—a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
70. Infrared thermographic techniques for non-destructive damage characterization of carbon fibre reinforced polymers during tensile fatigue testing10.1016/j.ijfatigue.2006.02.036 ↗
71. Fixation of long bone segmental defects: A biomechanical study
72. How stiff should semi-rigid fixation of the human tibia be? A clue to the answer10.1302/0301-620X.65B3.6841402 ↗
73. The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials10.1302/0301-620X.64B1.7040407 ↗
74. Fatigue of biomaterials: a review10.1016/S0142-1123(00)00052-9 ↗
75. Is hardware removal a necessity?
76. Effect of UD carbon on the specific mechanical properties of glass mat composites for marine applications10.1177/0021998309353215 ↗
77. Potential application of graphite fiber and methyl methacrylate resin composites as internal fixation plates10.1002/jbm.820080513 ↗
78. Biomechanical evaluation of periprosthetic femoral fracture fixation10.2106/JBJS.F.01561 ↗
79. Development of a multi-component fiber-reinforced composite implant for load-sharing conditions10.1016/j.medengphy.2008.11.006 ↗
80. Fatigue strength of human cortical bone: age, physical, and material heterogeneity effects10.1002/jbm.a.31576 ↗