In dentistry, prosthetic structures must be able to support masticatory loads combined with a high biocompatibility and wear resistance in the presence of a corrosive environment. In order to improve the simultaneous wear and corrosion response of highly biocompatible prosthetic structures, a veneering poly-ether-ether-ketone (PEEK) to Ti6Al4V substrate was assessed by tribocorrosion analyses under conditions mimicking the oral environment. Samples were synthesized by hot pressing the PEEK veneer onto Ti6Al4V cylinders. The tribocorrosion tests on Ti6Al4V or PEEK/Ti6Al4V samples were performed on a reciprocating ball-on-plate tribometer at 30N normal load, 1Hz and stroke length of 3mm. The tests were carried out in artificial saliva at 37°C. Open circuit potential (OCP) was measured before, during and after reciprocating sliding tests. The worn surfaces were characterized by scanning electron microscopy. The results revealed a lower wear rate on PEEK combined with a lower coefficient of friction (COF), when compared to Ti6Al4V. In fact, PEEK protected Ti6Al4V substrate against the corrosive environment and wear avoiding the release of metallic ions to the surrounding environment.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Corrosion and tribocorrosion behaviors of AISI 316 stainless steel and Ti6Al4V alloys in artificial seawater10.1016/S1003-6326(14)63157-5 ↗
2. Widespread dissemination of metal debris from implants10.1302/0301-620X.76B5.8083255 ↗
3. Dry sliding and tribocorrosion behaviour of hot pressed CoCrMo biomedical alloy as compared with the cast CoCrMo and Ti6Al4V alloys10.1016/j.matdes.2013.05.032 ↗
4. Occlusal wear simulation with the ACTA wear machine10.1016/0300-5712(94)90167-8 ↗
5. Scratch resistance of high performance polymers10.1016/j.triboint.2011.04.008 ↗
6. Dry sliding wear behavior of Ti–6Al–4V implant alloy subjected to various surface treatments10.1007/s12666-012-0147-4 ↗
7. Guleryuz, H., Cimenoglu, H., 2004. A study to improve tribological performance of Ti–6Al–4V alloy for biomedical applications. Medical Device Materials. Proceedings of the Materials & Processes for Medical Devices Conference. pp. 357–361.
8. Wear particles, periprosthetic osteolysis and the immune system10.1016/j.biomaterials.2007.06.035 ↗
9. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties10.1016/j.biomaterials.2009.12.030 ↗
10. Systemic metal–protein binding associated with total joint replacement arthroplasty10.1002/(SICI)1097-4636(20000305)49:3<353::AID-JBM8>3.0.CO;2-T ↗
11. Influence of surface conditioning on bonding to polyetheretherketon (PEEK)10.1016/j.dental.2012.09.010 ↗
12. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
13. Polyetheretherketone (PEEK) surface functionalization by low-energy ion-beam irradiation under a reactive O2 environment and its effect on the PEEK/copper10.1021/la035396h ↗
14. Effects of Ti ions and particles on neutrophil function and morphology10.1016/S0142-9612(02)00115-1 ↗
15. Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva10.1016/j.jmbbm.2013.01.019 ↗
16. Friction and wear behavior of flame-sprayed PEEK coatings10.1016/S0043-1648(02)00053-4 ↗
17. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants10.1002/jbm.b.32669 ↗
18. Electrochemical and materials aspects of tribocorrosion systems10.1088/0022-3727/39/15/S01 ↗
19. Artificial saliva for in vitro studies of dental materials10.1016/S0300-5712(96)00068-1 ↗
20. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
21. Fibroblast response to metallic debris in vitro10.2106/00004623-199306000-00005 ↗
22. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
23. Ourahmoune, R., Salvia, M., 2011. Effect of sandblasting substrate treatment on single lap shear strength of adhesively bonded PEEK and its composites. In: Proceedings of the18th International Conference on Composite Materials. pp. 2–7.
24. A New Ti–15Zr–4Nb–4Ta alloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
25. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
26. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
27. Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides10.1016/j.wear.2012.05.030 ↗
28. Wear and corrosion interactions on titanium in oral environment: literature review10.1007/s40735-015-0013-0 ↗
29. PEEK dental implants: a review of the literature10.1563/AAID-JOI-D-11-00002 ↗
30. Evaluation of tribological behaviour of PEEK and glass fibre reinforced PEEK composite under dry sliding and water lubricated conditions10.1016/j.wear.2008.02.008 ↗
31. Corrosion behaviour of titanium in the presence of Streptococcus mutans10.1016/j.jdent.2013.03.008 ↗
32. The effects on bone cells of metal ions released from orthopaedic implants. A review
33. Feedback control during mastication of solid food textures—a clinical-experimental study10.1016/S0022-3913(98)70134-9 ↗
34. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement10.2106/00004623-200004000-00002 ↗
35. Tribological behaviour of carbon-nanofibre-reinforced poly(ether ether ketone)10.1016/j.wear.2004.07.010 ↗
36. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface10.1016/j.spinee.2014.12.018 ↗
37. On dry sliding friction and wear behaviour of PEEK and PEEK/SiC-composite coatings10.1016/j.wear.2005.03.017 ↗