journal article·2009-07

The biomechanics of arterial elastin

Namrata Gundiah, Mark B. Ratcliffe, Lisa A. Pruitt

Publisher page

Abstract

Uniaxial mechanical experiments have shown that a neo-Hookean/Gaussian model is suitable to describe the mechanics of arterial elastin networks [Gundiah, N., Ratcliffe, M.B., Pruitt, L.A., 2007. Determination of strain energy function for arterial elastin: Experiments using histology and mechanical tests. J. Biomech. 40, 586-594]. Based on the three-dimensional elastin architecture in arteries, we have proposed an orthotropic material symmetry for arterial elastin consisting of two orthogonally oriented and symmetrically placed families of mechanically equivalent fibers. In this study, we use these results to describe the strain energy function for arterial elastin, with dependence on a reduced subclass of invariants, as W=W(I(1),I(4)). We use previously published equations for this dependence [Humphrey, J.D., Strumpf, R.K., Yin, F.C.P., 1990a. Determination of a constitutive relation for passive myocardium: I. A new functional form. J. Biomech. Eng. 112, 333-339], in combination with a theoretical guided Rivlin-Saunders framework [Rivlin, R.S., Saunders, D.W., 1951. Large elastic deformations of isotropic materials VII. Experiments on the deformation of rubber. Phil. Trans. R. Soc. A 243, 251-288] and biaxial mechanical experiments, to obtain the form of this dependence. Using mechanical equivalence of elastin in the circumferential and longitudinal directions, we add a term in I(6) to W that is similar to the form in I(4). We propose a semi-empirical model for arterial elastin given by W = c(0)(I(1) - 3) + c(1)(I(4) - 1)2 + c(2)(I(6) - 1)2, where c(0), c(1) and c(3) are unknown coefficients. We used the Levenberg-Marquardt algorithm to fit theoretically calculated and experimentally determined stresses from equibiaxial experiments on autoclaved elastin tissues and obtain c(0) = 73.96+/-22.51 kPa, c(1) = 1.18+/-1.79 kPa and c(2) = 0.8+/-1.26 kPa. Thus, the entropic contribution to the strain energy function, represented by c(0), is a dominant feature of elastin mechanics. Because there are no significant differences in the coefficients corresponding to invariants I(4) and I(6), we surmise that there is an equal distribution of fibers in the circumferential and axial directions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Connective tissue disorders research · Coronary Interventions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Optical properties of single elastic fibers indicate random protein conformation10.1038/287865a0 ↗
2. Banga · 1966
3. Transmural organization of the arterial media: The lamellar unit revisited10.1161/01.ATV.5.1.19 ↗
4. The structures of elastin and their function10.1016/S0300-9084(99)00221-7 ↗
5. Fung · 1993
6. Gosline · 1980
7. Elastic proteins: Biological roles and mechanical properties10.1098/rstb.2001.1022 ↗
8. Determination of strain energy function for arterial elastin: Experiments using histology and mechanical tests10.1016/j.jbiomech.2006.02.004 ↗
9. The elastic properties of elastin10.1021/ja01557a016 ↗
10. Elastic properties of elastin10.1002/bip.1974.360130404 ↗
11. Holzapfel · 2000
12. A new axisymmetrical membrane element for anisotropic, finite strain analysis of arteries10.1002/(SICI)1099-0887(199608)12:8<507::AID-CNM998>3.0.CO;2-K ↗
13. Determination of a constitutive relation for passive myocardium: I. A new functional form10.1115/1.2891193 ↗
14. Determination of a constitutive relation for passive myocardium: II. Parameter estimation10.1115/1.2891194 ↗
15. The structure and chemical characterization of elastin fibers as revealed by elastase and by electron microscopy10.1002/ar.1091140404 ↗
16. Elastin dehydration through the liquid and the vapor phase — A comparison of osmotic stress models10.1002/(SICI)1097-0282(199611)39:5<627::AID-BIP2>3.0.CO;2-Y ↗
17. The effects of hydration on the dynamic mechanical properties of elastin10.1002/bip.360290805 ↗
18. Mechanical properties of elastin along the thoracic aorta in the pig10.1016/j.jbiomech.2006.10.025 ↗
19. The influence of the invariant I8 on the stress-deformation and ellipticity characteristics of doubly-fiber reinforced non-linearly elastic solids10.1016/j.ijnonlinmec.2006.02.001 ↗
20. A theory of large elastic deformation10.1063/1.1712836 ↗
21. The chemistry of connective tissues. 2. Soluble proteins derived from partial hydrolysis of elastin10.1042/bj0610011 ↗
22. Remarks on the behavior of simple directionally reinforced incompressible nonlinearly elastic solids10.1023/A:1007410321319 ↗
23. Large elastic deformations of isotropic materials VII. Experiments on the deformation of rubber
24. The reason for the shape of the distensibility curves of arteries10.1139/y57-080 ↗
25. Molecular biology of elastin as related to aging and atherosclerosis10.1016/0531-5565(70)90017-3 ↗
26. Multiaxial mechanical behavior of biological materials10.1146/annurev.bioeng.5.011303.120714 ↗
27. Evolution of elastin structure10.1007/978-1-4684-9093-0_27 ↗
28. The elasticity of a network of long-chain molecules- II10.1039/TF9433900241 ↗
29. Instabilities of a finitely deformed fiber-reinforced elastic material10.1115/1.3166983 ↗
30. Elastin: A representative ideal protein elastomer10.1098/rstb.2001.1023 ↗
31. Wang, J., 2004. The contribution of elastin, collagen and smooth muscle cells to the biomechanics of large elastic arteries. In: Bioengineering, Berkeley, Ph.D. University of California Berkeley10.1115/IMECE2004-59886 ↗
32. A lamellar unit of aortic medial structure and function in mammals10.1161/01.RES.20.1.99 ↗
33. The degree of nonlinearity and anisotropy of blood vessel elasticity10.1073/pnas.94.26.14255 ↗
34. A strain energy function for arteries accounting for wall composition and structure10.1016/j.jbiomech.2003.11.026 ↗