Multiscale design of surface morphological gradient for osseointegration
Source abstract
Abstract
Rapid and stable osseointegration signifies a major concern in design of implantable prostheses, which stimulates continuous development of new implant materials and structures. This study aims to develop a graded configuration of a bead/particle coated porous surface for implants by exploring how its micromechanical features determine osseointegration through multiscale modeling and remodeling techniques. A typical dental implantation setting was exemplified for investigation by using the remodeling parameters determined from a systematic review of bone-implant-contact (BIC) ratio published in literature. The global responses of a macroscale model were obtained through 48 month remodeling simulation, which forms the basis for the 27 microscopic models created with different particle gradients ranging from 30 to 70μm. The osseointegration responses are evaluated in terms of the BIC ratio and the averaged 10% peak Tresca shear stress (PTS). Within the sampling designs considered, the configuration with 50-30-30μm particle sizes provides the best outcome, counting 20% more BIC ratio and 0.17MPa less PTS compared with the worst case scenario, also outperforming the best uniform morphology of 70μm particles. Furthermore, the response surface method (RSM) was utilized to formulate the bone remodeling responses in terms of gradient parameters across three layers. Gradient 30.0-30.0-32.1 is found an optimal gradient for BIC ratio, and 70-45.4-40.8 the best for the minimum PTS. The multiobjective optimization was finally performed to simultaneously maximize BIC ratio and minimize PTS for achieving the best possible overall outcome. Due to strong competition between these two design objectives, a Pareto front is generated. To make a proper trade-off, the minimum distance selection criterion is considered and the gradient of 37.1-70.0-67.7 appears an optimal solution. This study provides a novel surface configuration and design methodology for individual patient that allow optimizing topographical gradient for a desirable patient-specific biomechanical environment to promote osseointegration.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Cellular and Composite Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model10.1067/mpr.2001.112415 ↗
2. Framework for optimal design of porous scaffold microstructure by computational simulation of bone regeneration10.1016/j.biomaterials.2006.02.039 ↗
3. An evaluation of skeletal attachment to LTI pyrolytic carbon, porous titanium, and carbon-coated porous titanium implants10.1097/00003086-198401000-00033 ↗
4. Dental implant surface enhancement and osseointegration
5. Multiscale design and multiobjective optimization of orthopedic hip implants with functionally graded cellular material10.1115/1.4006115 ↗
6. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone10.1097/00003086-198007000-00045 ↗
7. Bradley, N., 2007. The response surface methodology. Department of Mathematical Sciences. South Bend, Indiana University. Master of Science in Applicaed Mathematics & Computer Science, 36–38.
8. Bone remodelling in bioshape10.1016/j.entcs.2010.12.003 ↗
9. Fibrin structure and cocentration alter clot elastic-modulus but do not alter platelet-mediated force development10.1097/00001721-199502000-00013 ↗
10. Characterization of functionally graded hydroxyapatite/titanium composite coatings plasma-sprayed on Ti alloys10.1002/jbm.b.30465 ↗
11. Computational design for multifunctional microstructural composites10.1142/S0217979209060920 ↗
12. Microstructure design of biodegradable scaffold and its effect on tissue regeneration10.1016/j.biomaterials.2011.03.064 ↗
13. A histological comparison in the dog of porous-coated vs threaded dental implants10.1177/00220345900690050401 ↗
14. Properties of solid core and porous surface Ti-6Al-4V implants manufactured by powder metallurgy10.1016/j.jallcom.2006.12.143 ↗
15. Biological factors contributing to failures of osseointegrated oral implants (I). Success criteria and epidemiology10.1046/j.0909-8836..t01-2-.x ↗
16. The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model
17. Prediction of mandibular bone remodelling induced by fixed partial dentures10.1016/j.jbiomech.2010.02.016 ↗
18. A comparative mechanical and bone remodelling study of all-ceramic posterior inlay and onlay fixed partial dentures10.1016/j.jdent.2011.10.003 ↗
19. Ductile sliding between mineral crystals followed by rupture of collagen crosslinks: experimentally supported micromechanical explanation of bone strength10.1016/j.jtbi.2009.05.021 ↗
20. Bone's mechanostat: a 2003 update10.1002/ar.a.10119 ↗
21. Multiobjective optimization of multi-cell sections for the crashworthiness design10.1016/j.ijimpeng.2007.09.003 ↗
22. Pore diameter of more than 100mum is not requisite for bone ingrowth in rabbits10.1002/jbm.1069 ↗
23. Strength of trabecular bone
24. Comparison of implant stability after different implant surface treatments in dog bone10.1590/S1678-77572010000400016 ↗
25. Systematic study of osteoblast and fibroblast response to roughness by means of surface-morphology gradients10.1016/j.biomaterials.2007.01.019 ↗
26. Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge10.1002/jbm.b.30233 ↗
27. A mathematical model for simulating the bone remodeling process under mechanical stimulus10.1016/j.dental.2006.10.004 ↗
28. Finite element based bone remodeling and resonance frequency analysis for osseointegration assessment of dental implant10.1016/j.finel.2011.03.009 ↗
29. Effect of bone to implant contact percentage on bone remodelling surrounding a dental implant10.1016/j.ijom.2010.03.020 ↗
30. Mandibular bone remodeling induced by dental implant10.1016/j.jbiomech.2009.08.024 ↗
31. Dental implant induced bone remodeling and associated algorithms10.1016/j.jmbbm.2008.11.007 ↗
32. Bone remodeling induced by dental implants of functionally graded materials10.1002/jbm.b.31531 ↗
33. Design optimization of functionally graded dental implant for bone remodeling10.1016/j.compositesb.2009.04.015 ↗
34. Bone ingrowth into a porous coated implant predicted by a mechano-regulatory tissue differentiation algorithm10.1007/s10237-007-0100-3 ↗
35. Surface engineering of titanium by collagen immobilization. Surface characterization and in vitro and in vivo studies10.1016/S0142-9612(03)00360-0 ↗
36. Investigation of the integration process of dental implants by means of a numerical analysis10.1016/S0109-5641(97)80103-0 ↗
37. Osteocyte function, osteocyte death and bone fracture resistance10.1016/S0303-7207(99)00174-4 ↗
38. O'Brien · 2008
39. Physical characteristics of Ti-6Al-4V implants fabricated by electrodischarge compaction10.1002/jbm.820251202 ↗
40. Empirical comparison of MOPSO methods—guide selection and diversity preservation
41. 3D hierarchical geometric modeling and multiscale FE analysis as a base for individualized medical diagnosis of bone structure10.1016/j.bone.2010.12.022 ↗
42. Multiscale FE method for analysis of bone micro-structures10.1016/j.jmbbm.2011.03.003 ↗
43. An effective use of crowding distance in multiobjective particle swarm optimization
44. Elasticity and fracture strain of whole blood clots
45. A comparison of 2D and 3D finite element analysis of a restored tooth10.1111/j.1365-2842.2005.01552.x ↗
46. Surface morphology optimization for osseointegration of coated implants10.1016/j.biomaterials.2010.05.077 ↗
47. A numerical investigation of porous titanium as orthopedic implant material10.1016/j.mechmat.2011.06.002 ↗
48. Effect of microstructural configurations on the mechanical responses of porous titanium: a numerical design of experiment analysis for orthopedic applications10.1016/j.mechmat.2008.03.009 ↗
49. Zirconium oxide coating improves implant osseointegration in vivo10.1016/j.dental.2007.06.003 ↗
50. On stiffness of scaffolds for bone tissue engineering-a numerical study10.1016/j.jbiomech.2010.02.020 ↗
51. Crashworthiness design of vehicle by using multiobjective robust optimization10.1007/s00158-010-0601-z ↗
52. Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits10.1016/S8756-3282(97)00204-4 ↗
53. A mathematical model of bone remodelling under overload and its application to evaluation of bone resportion around dental implants
54. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss10.1016/j.jbiomech.2012.05.032 ↗
55. Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants10.1016/j.dental.2008.03.029 ↗
56. Finite element analysis of crestal bone loss around porous-coated dental implants10.1002/jab.770060408 ↗
57. Mechanical stress-induced apoptosis in the cardiovascular system
58. Rabbit annulus fibrosus cell apoptosis induced by mechanical overload via a mitochondrial apoptotic pathway
59. Processing and biocompatibility evaluation of laser processed porous titanium10.1016/j.actbio.2007.05.009 ↗
60. A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone10.1016/j.jbiomech.2006.11.019 ↗
61. Morphological behavior of osteoblast-like cells on surface-modified titanium in vitro10.1016/S0142-9612(01)00259-9 ↗
62. Preparation of graded porous titanium coatings on titanium implant materials by plasma spraying10.1002/1097-4636(200011)52:2<333::AID-JBM12>3.0.CO;2-T ↗