journal article·2012-11

Fabric-based Tsai–Wu yield criteria for vertebral trabecular bone in stress and strain space

Uwe Wolfram, Thomas Gross, Dieter H. Pahr, Jakob Schwiedrzik, Hans-Joachim Wilke, Philippe K. Zysset

Publisher page

Abstract

Osteoporosis related vertebral fractures are an increasing clinical problem in ageing societies. The prediction of vertebral fracture load from QCT-based anatomy-specific finite element simulations could be very useful in the management of patients with osteoporosis, especially with regard to a possible fracture prevention or treatment optimisation. A key property in finite element analysis is the yield surface for the trabecular bone material. This study is aimed at identifying continuum-level yield criteria for vertebral trabecular bone using micro-finite element models subjected to uni-axial, shear, and tri-axial loading. A fabric-dependent, orthotropic Tsai-Wu yield criterion is proposed in both stress and strain spaces. Nonlinear micro-finite element models of cubic vertebral trabecular bone samples with 5.62 mm edge length were generated from μCT-scans. Kinematic boundary conditions were imposed and the specimen was loaded force controlled beyond yield in 17 different load cases (six uni-axial, three shear and eight multi-axial). The proposed yield criteria were fitted to the resulting yield data. Yield strains on-axis were significantly lower (10% in tension and 6% in compression) than in the transverse directions. Average yield strains were 0.7% in tension, 1.1% in compression, 1.0% in shear and ranged from 0.6% to 1.1% under multi-axial loading. In axial direction, maximum yield stress was 2.6 MPa in tension and 4.7 MPa in compression. Lowest shear stress was found in the transverse plane with 1.3 MPa. Multi-axial yield stresses ranged between values for uni-axial tension and compression. Yield stresses depended significantly and substantially on both volume fraction and fabric. Yield strains depended also significantly on both bone volume fraction and fabric, but only weakly on the former. The standard error of the estimate and the concordance correlation coefficient of the yield surface were 5.47% and 0.93 in strain space and 13.58% and 0.96 in stress space. The results of this study are not only consistent with experimental data from the literature but also extend the current knowledge of yield to multi-axial load cases that can hardly be realised in a biomechanical experiment. The presented yield data and criteria will help improving the prediction of vertebral ultimate load using anatomy-specific finite element models.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Bone health and osteoporosis research · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. The modified super-ellipsoid yield criterion for human trabecular bone10.1115/1.1763177 ↗
2. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
3. Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site10.1016/j.jbiomech.2007.05.008 ↗
4. Heterogeneity of yield strain in low-density versus high-density human trabecular bone10.1016/j.jbiomech.2009.05.023 ↗
5. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
6. Fabric dependence of an anisotropic strength criterion10.1016/0167-6636(86)90022-0 ↗
7. A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone10.1115/1.2798339 ↗
8. Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests
9. Application of the tsai-wu quadratic multiaxial failure criterion to bovine trabecular bone10.1115/1.2798051 ↗
10. Yield strain behaviour of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
11. A concordance correlation coefficient to evaluate reproducibility10.2307/2532051 ↗
12. Micromechanical approach to the strength properties of frictional geomaterials10.1016/j.euromechsol.2008.03.002 ↗
13. Vertebral fracture assessment in healthy men: prevalence and risk factors10.1016/j.bone.2008.05.008 ↗
14. The role of fabric in the quasi-static compressive mechanical properties of human trabecular bone from various anatomical locations10.1007/s10237-006-0073-7 ↗
15. Trabecular bone modulus-density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
16. Damage in trabecular bone at small strains10.1080/09243860500095273 ↗
17. Biaxial failure behavior of bovine tibial trabecular bone10.1115/1.1517566 ↗
18. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
19. Influence of boundary conditions on computed apparent elastic properties of cancellous bone10.1007/s10237-007-0109-7 ↗
20. R Development Core Team, 2008. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, Vienna, Austria, ISBN 3-900051-07-0. 〈http://www.R-project.org〉.
21. Direct mechanics assessment of elastic constants of elastic symmetries and properties of trabecular bone architecture10.1016/S0021-9290(96)80021-2 ↗
22. Multi-axial mechanical properties of human trabecular bone10.1007/s10237-008-0128-z ↗
23. Biomechanics of osteoporotic fractures10.1016/j.injury.2007.08.014 ↗
24. A general theory of strength for anisotropic materials10.1177/002199837100500106 ↗
25. The effects of side-artifacts on the elastic modulus of trabecular bone10.1016/j.jbiomech.2006.05.012 ↗
26. Micro-finite element simulation of trabecular-bone post-yield behaviour-effects of material model, element size and type10.1080/10255840701848756 ↗
27. Vertebral trabecular main direction can be determined from clinical ct datasets using the gradient structure tensor and not the inertia tensor—a case study10.1016/j.jbiomech.2009.04.006 ↗
28. Rehydration of vertebral trabecular bone: influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level10.1016/j.bone.2009.09.035 ↗
29. Valid μfinite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions10.1016/j.jbiomech.2010.02.026 ↗
30. Damage accumulation in vertebral trabecular bone depends on loading mode and direction10.1016/j.jbiomech.2011.01.018 ↗
31. A review of morphology-elasticity relationships in human trabecular bone: theories and experiments10.1016/S0021-9290(03)00128-3 ↗
32. A novel 3d microstructural model for trabecular bone: I. The relationship between fabric and elasticity10.1080/01495739808936710 ↗
33. Zysset · 2006