journal article·2016-07Open access

Tribocorrosion behavior of biofunctional titanium oxide films produced by micro-arc oxidation: Synergism and mechanisms

Isabella da Silva Vieira Marques, Maria Fernanda Alfaro, Nilson Cristino da Cruz, Marcelo Ferraz Mesquita, Christos Takoudis, Cortino Sukotjo, Mathew T. Mathew, Valentim Adelino Ricardo Barão

Abstract

Dental implants, inserted into the oral cavity, are subjected to a synergistic interaction of wear and corrosion (tribocorrosion), which may lead to implant failures. The objective of this study was to investigate the tribocorrosion behavior of Ti oxide films produced by micro-arc oxidation (MAO) under oral environment simulation. MAO was conducted under different conditions as electrolyte composition: Ca/P (0.3M/0.02M or 0.1M/0.03M) incorporated with/without Ag (0.62g/L) or Si (0.04M); and treatment duration (5 and 10min). Non-coated and sandblasted samples were used as controls. The surfaces morphology, topography and chemical composition were assessed to understand surface properties. ANOVA and Tukey׳s HSD tests were used (α=0.05). Biofunctional porous oxide layers were obtained. Higher Ca/P produced larger porous and harder coatings when compared to non-coated group (p<0.001), due to the presence of rutile crystalline structure. The total mass loss (Kwc), which includes mass loss due to wear (Kw) and that due to corrosion (Kc) were determined. The dominant wear regime was found for higher Ca/P groups (Kc/Kw≈0.05) and a mechanism of wear-corrosion for controls and lower Ca/P groups (Kc/Kw≈0.11). The group treated for 10min and enriched with Ag presented the lowest Kwc (p<0.05). Overall, MAO process was able to produce biofunctional oxide films with improved surface features, working as tribocorrosion resistant surfaces.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Tribocorrosion behaviour of anodic titanium oxide films produced by plasma electrolytic oxidation for dental implants10.1002/ls.1234 ↗
2. Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants10.1088/0022-3727/46/40/404001 ↗
3. The role of lipopolysaccharide on the electrochemical behavior of titanium10.1177/0022034510396880 ↗
4. Stability of cp-Ti and Ti–6Al–4V alloy for dental implants as a function of saliva pH - an electrochemical study10.1111/j.1600-0501.2011.02265.x ↗
5. The antimicrobial efficacy of polyamide 6/silver-nano- and microcomposites10.1016/j.matchemphys.2007.09.002 ↗
6. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti–6Al–4V alloy with a smooth surface or treated with double-acid-etching10.1371/journal.pone.0093377 ↗
7. Biotribocorrosion (tribo-electrochemical) characterization of anodized titanium biomaterial containing calcium and phosphorus before and after osteoblastic cell culture10.1002/jbm.b.33236 ↗
8. Fernandes · Surf. Coat. Technol. · 2006 · 200 · 621810.1016/j.surfcoat.2005.11.069 ↗
9. Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications10.1016/S0142-9612(03)00560-X ↗
10. Evaluation of corrosion and tribocorrosion of plasma electrolytic oxidation treated Ti–6Al–4V alloy10.1016/j.surfcoat.2014.01.042 ↗
11. Implant osseointegration and the role of microroughness and nanostructures: lessons for spine implants10.1016/j.actbio.2014.03.037 ↗
12. Fabrication and evaluation of a bioactive Sr–Ca–P contained micro-arc oxidation coating on magnesium strontium alloy for bone repair application
13. Formation and characterization of anodic titanium oxide films containing Ca and P10.1002/jbm.820290110 ↗
14. Thick rutile layer on titanium for tribological applications10.1016/j.triboint.2005.08.004 ↗
15. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages10.1016/j.matchar.2006.03.020 ↗
16. Electrochemical methods in tribocorrosion: a critical appraisal10.1016/S0013-4686(01)00679-X ↗
17. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
18. Plasma electrolytic oxidation coatings on γTiAl alloy for potential biomedical applications10.1002/jbm.b.33079 ↗
19. Surface characteristics and biocompatibility of sandblasted and acid-etched titanium surface modified by ultraviolet irradiation: an in vitro study10.1002/jbm.b.32727 ↗
20. Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva10.1016/j.jmbbm.2013.01.019 ↗
21. Effects of cathodic voltages on the structure and properties of ceramic coatings formed on NiTi alloy by micro-arc oxidation10.1016/j.matchemphys.2010.01.002 ↗
22. Effect of load deflection on corrosion behavior of NiTi wire10.1177/154405910708600610 ↗
23. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
24. Electrochemical behavior of bioactive coatings on cp-Ti surface for dental application10.1016/j.corsci.2015.07.019 ↗
25. Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion10.1002/jbm.b.32735 ↗
26. What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?
27. Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems10.1016/j.wear.2011.01.086 ↗
28. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
29. Wear‐accelerated corrosion of passive metals in tribocorrosion systems10.1149/1.1838341 ↗
30. Metal release from ceramic coatings for dental implants10.1016/j.dental.2013.12.011 ↗
31. Understanding growth mechanisms and tribocorrosion behaviour of porous TiO2 anodic films containing calcium, phosphorous and magnesium10.1016/j.apsusc.2015.02.163 ↗
32. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
33. X-ray diffraction and infrared spectroscopy analyses on the crystallinity of engineered biological hydroxyapatite for medical application10.1088/1757-899X/79/1/012028 ↗
34. Micro-arc oxidation as a tool to develop multifunctional calcium-rich surfaces for dental implant applications10.1016/j.msec.2015.05.012 ↗
35. Tribocorrosive behaviour of commonly used temporomandibular implants in a synovial fluid-like environment: Ti–6Al–4V and CoCrMo10.1088/0022-3727/46/40/404002 ↗
36. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
37. Effects of micrometric titanium particles on osteoblast attachment and cytoskeleton architecture10.1016/j.actbio.2009.10.033 ↗
38. H2O2/HCl and heat-treated Ti–6Al-4V stimulates pre-osteoblast proliferation and differentiation10.1016/j.tripleo.2009.05.033 ↗
39. Biomimetic apatite coatings on micro-arc oxidized titania10.1016/j.biomaterials.2003.09.103 ↗
40. Do oral biofilms influence the wear and corrosion behavior of titanium?10.1080/08927011003767985 ↗
41. Mapping erosion-corrosion of carbon steel in oil exploration conditions: Some new approaches to characterizing mechanisms and synergies10.1016/j.triboint.2010.01.005 ↗
42. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant10.1016/S0142-9612(03)00261-8 ↗
43. Oxidized, bioactive implants are rapidly and strongly integrated in bone. Part 1--experimental implants10.1111/j.1600-0501.2005.01230.x ↗
44. The bone response of oxidized bioactive and non-bioactive titanium implants10.1016/j.biomaterials.2005.04.058 ↗
45. The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes10.1016/S1350-4533(01)00050-9 ↗
46. Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – a review10.1016/j.actbio.2013.10.036 ↗
47. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗
48. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
49. Development of Ti–C–N coatings with improved tribological behavior and antibacterial properties10.1016/j.jmbbm.2015.10.020 ↗
50. Enhanced performance of osteoblasts by silicon incorporated porous TiO2 coating10.1016/S1005-0302(12)60030-9 ↗
51. Growth, microstructure and mechanical properties of microarc oxidation coatings on titanium alloy in phosphate-containing solution10.1016/j.apsusc.2004.03.231 ↗
52. Investigation of wear behavior of titanium oxide films, produced by anodic oxidation, on commercially pure titanium in vacuum conditions10.1016/j.surfcoat.2010.08.079 ↗
53. The relationship of surface roughness and cell response of chemical surface modification of titanium10.1007/s10856-012-4611-9 ↗
54. Osteoblast-like cell adhesion on porous silicon-incorporated TiO2 coating prepared by micro-arc oxidation10.1002/jbm.b.31804 ↗
55. Structure and properties of crystalline titanium oxide layers deposited by reactive pulse magnetron sputtering10.1016/j.surfcoat.2003.10.115 ↗