Dynamic compressive response of bovine liver tissues
Source abstract
Abstract
This study aims to experimentally determine the strain rate effects on the compressive stress-strain behavior of bovine liver tissues. Fresh liver tissues were used to make specimens for mechanical loading. Experiments at quasi-static strain rates were conducted at 0.01 and 0.1 s(-1). Intermediate-rate experiments were performed at 1, 10, and 100 s(-1). High strain rate (1000, 2000, and 3000 s(-1)) experiments were conducted using a Kolsky bar modified for soft material characterization. A hollow transmission bar with semi-conductor strain gages was used to sense the weak forces from the soft specimens. Quartz-crystal force transducers were used to monitor valid testing conditions on the tissue specimens. The experiment results show that the compressive stress-strain response of the liver tissue is non-linear and highly rate-sensitive, especially when the strain rate is in the Kolsky bar range. The tissue stiffens significantly with increasing strain rate. The responses from liver tissues along and perpendicular to the liver surface were consistent, indicating isotropic behavior.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: High-Velocity Impact and Material Behavior · Automotive and Human Injury Biomechanics · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. A 10-year experience of complex liver trauma10.1046/j.1365-2168.2002.02272.x ↗
2. Brands, D.W.A., 2002. Predicting brain mechanics during closed head impact — numerical and constitutive aspects. Ph.D. Dissertation Thesis, University of Eindhoven, Eindhoven, The Netherlands.
3. Measuring in-vivo animal soft tissue properties for haptic modeling in surgical simulation
4. In-vivo and in-situ compressive properties of porcine abdominal soft tissues
5. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure10.1016/j.jbiomech.2010.03.038 ↗
6. Measurement of soft-tissue mechanical properties to support development of a physically based virtual animal model
7. Measurements and modeling of the compliance of human and porcine organs10.1016/S1361-8415(01)00048-2 ↗
8. Inertial effects of quartz force transducers embedded in a split Hopkinson pressure bar10.1007/BF02428167 ↗
9. Chafi, M.S., Karami, G., Ziejewski, M., 2007. Simulation of blast-head interactions to study traumatic brain injury. In: The Proceeding of ASME International Mechanical Engineering Congress and Exposition, Seattle, Washington, USA.
10. A quartz-crystal-embedded split Hopkinson pressure bar for soft materials10.1007/BF02327540 ↗
11. A split Hopkinson bar technique for low-impedance materials10.1007/BF02331109 ↗
12. Mechanical compliance of the endocardium10.1016/S0021-9290(02)00228-2 ↗
13. Transversely isotropic properties of porcine liver tissue: experiments and constitutive modeling10.1007/s11517-006-0137-y ↗
14. Constitutive modeling of liver tissue: experiment and theroy10.1007/s10439-009-9812-0 ↗
15. Mechanical characterization of the liver capsule and parenchyma
16. A biomedical model of the liver for reality-based haptic feedback
17. Hu, T., Desai, J., 2004. Soft-tissue material properties under large deformation: strain rate effect. In: Proceeding of the 26th Annual International Conference of the IEEE EMBS, San Francisco, CA, USA, pp. 2758–2761.10.1109/IEMBS.2004.1403789 ↗
18. War surgery of the abdomen
19. Constitutive modeling of porcine liver in indentation using 3D ultrasound imaging10.1016/j.jmbbm.2008.08.006 ↗
20. Independent testing of soft tissue visco-elasticity using indentation and rotary shear deformations
21. An investigation of the mechanical properties of materials at very high rates of loading
22. On the visco-elastic character of liver tissue: experiments and modeling of the linear behavior
23. The mechanical response of human liver and its relation to histology: an in-vivo study10.1016/j.media.2007.06.010 ↗
24. Impact injury mechanisms in abdominal organs
25. Lubricated squeezing flow: a useful method for measureing the viscoelastic properties of soft tissue
26. In-vivo mechanical characterization of human liver10.1016/j.media.2007.10.001 ↗
27. Evaluation of the mechanical properties of human liver and kidney through aspiration experiments10.3233/THC-2004-12306 ↗
28. The effects of testing environment on the viscoelastic properties of soft tissues
29. Management of liver trauma10.1046/j.1365-2168.1999.01210.x ↗
30. Dynamic mechanical response of bovine gray matter and white matter brain tissues under compression10.1016/j.jbiomech.2009.01.023 ↗
31. Dynamic mechanical response of renal cortex under compression: strain rate effect
32. In-vitro measurement of mechanical properties of liver tissue under compression and elongation using a new test piece holding method with surgical glue
33. Santago, A., 2010. Characterizing the biomechanical response of the liver. MS Thesis.
34. Mechanical properties of soft human tissues under dynamic loading10.1016/j.jbiomech.2006.09.021 ↗
35. Dynamic stress equilibrium in split hopkinson pressure bar tests on soft materials10.1007/BF02427897 ↗
36. Dynamic and quasi-static compression response of porcine muscle10.1016/j.jbiomech.2007.02.001 ↗
37. Using pressure to predict liver injury risk from blunt impact
38. Mechanical characterization of porcine abdominal organs
39. A study on the mechanical properties of the kidney, liver, and spleen, by means of tensile stress test with variable strain velocity
40. Penetrating liver war injury: a report on 172 cases10.1093/milmed/168.5.419 ↗
41. An experimental study on biomechanical properties of hepatic tissue using a new measuring method
42. Elastic modulus of human liver and correlation to pathology10.1016/S0301-5629(02)00489-1 ↗