journal article·2011-11

Thiel-fixation preserves the non-linear load–deformation characteristic of spinal motion segments, but increases their flexibility

Hans-Joachim Wilke, Karin Werner, Kim Häussler, Michael Reinehr, Tobias M. Böckers

Publisher page

Abstract

Human cadaveric specimens are recommended as the best option for in-vitro tests. However, fresh human spine specimens are often difficult to obtain. Further problems are the potential risk of infection and they can only be used over a limited test period. Therefore, the use of embalmed specimens is often discussed. The most common method is formalin fixation. However, this type of embalming can result in failure, because the biomechanical properties of the tissue is partially influenced. In recent years the development of the new method, the fixation according to Thiel, could provide an alternative to fresh or formalin-fixed specimens. The aim of the present study is to compare the biomechanical properties between fresh and Thiel-fixed spine specimens, and to compare the data to previous data of a test with formalin fixation. For the study, six L1-L2 spinal segments from 16-week-old calves were biomechanically tested. The parameters, range of motion and neutral zone, were determined in flexion/extension, right/left lateral bending and left/right axial rotation. The results showed that the specimens kept their non-linear load-deformation-characteristic after Thiel fixation. The range of motion of Thiel-fixed specimens increased relative to the unembalmed state by approximately 22% in flexion-extension, 23% in lateral bending (p<0.05) and 45% in axial rotation (p<0.05). In conclusion, the results still suggest a preference for fresh cadaveric spine specimens for quantitative biomechanical in-vitro testing, because they provide the best physiological conditions. However, for preliminary tests, which may only be used for orientation, embalmed specimens using the Thiel fixation method might serve as an alternative. Compared to formalin-fixated specimens which become approximately 5 times stiffer and completely lose their non-linear load-deformation-characteristic, as found in a previous study; the Thiel fixation maintains the non-linear load-deformation-characteristic but increases the range of motion.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Musculoskeletal pain and rehabilitation · Scoliosis diagnosis and treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Thiel method fixed cadaver ears. A new procedure for graduate and continuing education in middle ear surgery10.1007/s00106-001-0601-9 ↗
2. Comparison of fresh and Thiel’s embalmed cadavers according to the suitability for ultrasound-guided regional anesthesia of the cervical region10.1007/s00276-009-0477-z ↗
3. Density of fresh and embalmed human compact and cancellous bone10.1002/ajpa.1330290113 ↗
4. hard tissue biochemistry: a comparison of fresh-frozen and formalin-fixed tissue samples10.1007/BF02411262 ↗
5. The collagen fibril—a model system for studying the staining and fixation of a protein10.1016/0892-0354(90)90018-N ↗
6. Biomechanical studies on the lumbar spine and pelvis10.2106/00004623-195941020-00010 ↗
7. Thiel embalming technique: a valuable method for teaching oral surgery and implantology
8. Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests?10.1007/s00586-007-0485-9 ↗
9. Comparison of fixation of spinal fractures
10. A biomechanical analysis of spinal instrumentation systems in thoracolumbar fractures. Comparison of traditional Harrington distraction instrumentation with segmental spinal instrumentation10.1097/00007632-198504000-00004 ↗
11. The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone10.1016/j.clinbiomech.2008.07.007 ↗
12. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework10.1097/00007632-198810000-00013 ↗
13. Biomechanical time-tolerance of fresh cadaveric human spine specimens10.1002/jor.1100030305 ↗
14. Surgical procedures in mouth, jaw and facial surgery in Thiel embalmed body donors10.1007/PL00010796 ↗
15. An FT-IR microscopic investigation of the effects of tissue preservation on bone10.1007/BF00296221 ↗
16. Biomechanical analysis of structural stability of internal fixation in fractures of the thoracolumbar spine
17. The preservation of the whole corpse with natural color10.1016/S0940-9602(11)80346-8 ↗
18. Supplement to the conservation of an entire cadaver according to W. Thiel10.1016/S0940-9602(02)80121-2 ↗
19. Effect of long-term preservation on the mechanical properties of cortical bone in goats10.1080/17453670810016759 ↗
20. Changes in tensile strength characteristics and histology of rabbit ligaments induced by different modes of postmortal storage10.3109/17453676608993274 ↗
21. A universal spine tester for in vitro experiments with muscle force simulation10.1007/BF02221446 ↗
22. Biomechanical comparison of calf and human spines10.1002/jor.1100140321 ↗
23. Formalin fixation strongly influences biomechanical properties of the spine10.1016/S0021-9290(96)80016-9 ↗
24. Are sheep spines a valid biomechanical model for human spines?10.1097/00007632-199710150-00009 ↗
25. Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition10.1002/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D ↗
26. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants10.1007/s005860050045 ↗
27. Is it possible to simulate physiologic loading conditions by applying pure moments? a comparison of in vivo and in vitro load components in an internal fixator10.1097/00007632-200103150-00014 ↗