On the mechanical integrity of retrieved dental implants
Source abstract
Abstract
The objective of this work is to investigate the potential state of mechanical damage in used, albeit mechanically intact, dental implants, after their retrieval from the oral cavity because of progressive bone loss (peri-implantitis). 100 retrieved dental implants were characterized with no medical record made available prior to the analysis. The implants' composition, dimensions, and surface treatments were characterized using energy dispersive X-ray analysis and scanning electron microscopy (SEM-EDX). Each implant was thoroughly examined for signs of mechanical defects and damage. The implants represent a random combination of two materials, titanium alloy (Ti-6Al-4V) and commercially pure titanium (CP-Ti), surface treatments and geometries. Two kinds of surface defects were identified: crack-like defects and full cracks that were arbitrarily divided according to their length and appearance. We found that over 60% of the implants contained both crack-like defects and full cracks. In the retrieved sample, we observed that the CP-Ti implants contained more defects and cracks than the Ti-6Al-4V ones. For the various surface roughening treatments, a general correlation with the presence of defects was observed, but without a clear differentiation between the treatments. The high incidence of embedded particles among the observed defect further strengthens the role played by the particles upon defects generation, some of which later evolve into full cracks. It was also found that the dimensions of the implant (width and length) were not correlated with the observed defects, for this specific sample. Our observations indicate that early retrieval of biologically failed implants, many of which contain early signs of mechanical failure as shown here, does actually hinder the later occurrence of implant fracture. It seems that once biological complications will be successfully overcome, such defects might grow later into full cracks as a result of cyclic mastication loads (fatigue). In such a case, the occurrence of implants' fracture is likely to markedly increase.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years10.1034/j.1600-051X.29.s3.12.x ↗
2. Prosthetic complications in fixed endosseous implant-borne reconstructions after an observations period of at least 40 months10.1111/j.1365-2842.2006.01638.x ↗
3. Practice-based evidence from 29-year outcome analysis of management of the edentulous jaw using osseointegrated dental implants10.1111/jopr.12084 ↗
4. Osseointegrated implant fracture: causes and treatment10.1563/AAID-JOI-D-09-00135.1 ↗
5. Clinical complications with implants and implant prostheses10.1016/S0022-3913(03)00212-9 ↗
6. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
7. Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media10.1016/j.biomaterials.2005.08.012 ↗
8. Characteristics of early versus late implant failure: a retrospective study10.1016/j.joms.2009.07.050 ↗
9. Fractures of the fixture component of an osseointegrated implant
10. The effect of machined topography and integrity on fatigue life10.1016/j.ijmachtools.2003.10.018 ↗
11. A systematic review of biologic and technical complications with fixed implant rehabilitations for edentulous patients
12. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years
13. Improvements in implant dentistry over the last decade: comparison of survival and complication rates in older and newer publications
14. Meta-analysis of oral implant fracture incidence and related determinants10.1155/2014/263925 ↗
15. Identification of failure mechanisms in retrieved fractured dental implants10.1016/j.engfailanal.2014.01.002 ↗
16. Mechanical assessment of grit blasting surface treatments of dental implants10.1016/j.jmbbm.2014.07.027 ↗
17. Effect of dental implant diameter on fatigue performance. Part I: Mechanical behavior10.1111/j.1708-8208.2012.00477.x ↗
18. Effect of dental implant diameter on fatigue performance. Part II: Failure analysis10.1111/j.1708-8208.2012.00476.x ↗
19. The effect of oral-like environment on dental implants’ fatigue performance10.1111/clr.12084 ↗
20. Long-term implant survival and success: a 10–16-year follow-up of non-submerged dental implants10.1111/j.1600-0501.2010.01912.x ↗
21. Time dependent failure rate and marginal bone loss of implant supported prostheses: a 15-year follow-up study10.1007/s007840050107 ↗
22. Suresh · 1994
23. Tonetti M.S., Schmid J. Pathogenesis of implant failures. Periodontol 2000 1994; 4:127-13810.1111/j.1600-0757.1994.tb00013.x ↗
24. Effects of titanium surface topography on bone integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
25. Clinical evaluation of small-diameter ITI implants: a prospective study