Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation
Source abstract
Abstract
The use of synchrotron radiation micro-computed tomography (SR-microCT) is becoming increasingly popular for studying the relationship between microstructure and bone mechanics subjected to in situ mechanical testing. However, it is well known that the effect of SR X-ray radiation can considerably alter the mechanical properties of bone tissue. Digital volume correlation (DVC) has been extensively used to compute full-field strain distributions in bone specimens subjected to step-wise mechanical loading, but tissue damage from sequential SR-microCT scans has not been previously addressed. Therefore, the aim of this study is to examine the influence of SR irradiation-induced microdamage on the apparent elastic properties of trabecular bone using DVC applied to in situ SR-microCT tomograms obtained with different exposure times. Results showed how DVC was able to identify high local strain levels (> 10,000 µε) corresponding to visible microcracks at high irradiation doses (~ 230 kGy), despite the apparent elastic properties remained unaltered. Microcracks were not detected and bone plasticity was preserved for low irradiation doses (~ 33 kGy), although image quality and consequently, DVC performance were reduced. DVC results suggested some local deterioration of tissue that might have resulted from mechanical strain concentration further enhanced by some level of local irradiation even for low accumulated dose.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source
2. Damage assessment in metallic structural materials using high resolution synchrotron X-ray tomography10.1016/S0168-583X(02)01692-0 ↗
3. Clinical evaluation of bone strength and fracture risk10.1007/s11914-017-0346-3 ↗
4. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone10.1016/j.bone.2010.02.025 ↗
5. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
6. Battistoni, G., Cerutti, F., Fassò, A., Ferrari, A., Muraro, S., Ranft, J., Roesler, S., Sala, P.R., 2007. The FLUKA code: Description and benchmarking. In: Proceedings of the AIP Conference Proceedings, vol. 896, pp. 31–49. doi: 〈http://dx.doi.org/10.1063/1.2720455〉.10.1063/1.2720455 ↗
7. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
8. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
9. Launch of the I13-2 data beamline at the Diamond Light Source synchrotron10.1088/1742-6596/849/1/012038 ↗
10. The FLUKA Code: developments and challenges for high energy and medical applications10.1016/j.nds.2014.07.049 ↗
11. Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images10.1088/0031-9155/58/22/8099 ↗
12. Bone quality: where do we go from here?10.1007/s00198-003-1489-x ↗
13. In situ experiments with X ray tomography: an attractive tool for experimental mechanics10.1007/s11340-010-9333-7 ↗
14. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
15. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
16. Precision of DVC approaches for strain analysis in bone imaged with µCT at different dimensional levels10.3389/fmats.2017.00031 ↗
17. Application of digital volume correlation to study the efficacy of prophylactic vertebral augmentation10.1016/j.clinbiomech.2016.07.010 ↗
18. Bone J: free and extensible bone image analysis in Image J10.1016/j.bone.2010.08.023 ↗
19. In-situ deformation of an open-cell flexible polyurethane foam characterised by 3D computed microtomography10.1023/A:1014920902712 ↗
20. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
21. Extracting accurate strain measurements in bone mechanics: a critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
22. Nanoscale changes in collagen are reflected in physical and mechanical properties of bone at the microscale in diabetic rats10.1016/j.bone.2013.11.015 ↗
23. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
24. Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra10.1016/j.jbiomech.2013.04.004 ↗
25. Significant deterioration in nanomechanical quality occurs through incomplete extrafibrillar mineralization in rachitic bone: evidence from in-situ synchrotron X-ray scattering and backscattered electron imaging10.1002/jbmr.1495 ↗
26. Multiscale alterations in bone matrix quality increased fragility in steroid induced osteoporosis10.1016/j.bone.2015.11.019 ↗
27. Theoretical analysis of the experimental artifact in trabecular bone compressive modulus10.1016/0021-9290(93)90021-6 ↗
28. Feasibility of micro-crack detection in human trabecular bone images from 3D synchrotron microtomography
29. Variability and anisotropy of mechanical behavior of cortical bone in tension and compression10.1016/j.jmbbm.2013.02.021 ↗
30. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
31. Synchrotron imaging assessment of bone quality10.1007/s12018-016-9223-3 ↗
32. Long-term effects of bisphosphonate therapy: perforations, microcracks and mechanical properties
33. Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis10.1016/j.medengphy.2013.02.001 ↗
34. Microdamage accumulation in bovine trabecular bone in uniaxial compression10.1115/1.1428745 ↗
35. Properties of growing trabecular ovine bone. Part I: mechanical and physical properties10.1302/0301-620X.82B6.0820910 ↗
36. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
37. Sterilization of allograft bone: effects of gamma irradiation on allograft biology and biomechanics10.1007/s10561-006-9020-1 ↗
38. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
39. Differences in the mechanical behavior of cortical bone between compression and tension when subjected to progressive loading10.1016/j.jmbbm.2008.11.008 ↗
40. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements10.1016/j.jbiomech.2006.11.020 ↗
41. 3D local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
42. Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: an organ-level study10.1016/j.jbiomech.2016.10.018 ↗
43. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
44. Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code10.1088/0031-9155/52/12/004 ↗
45. Coherent imaging at the Diamond beamline I13
46. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
47. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
48. Peirce's criterion for the elimination of suspect experimental data
49. Effect of high-energy X-ray doses on bone elastic properties and residual strains10.1016/j.jmbbm.2011.05.035 ↗
50. SPECTRA: a synchrotron radiation calculation code10.1107/S090904950101425X ↗
51. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light10.1016/j.bone.2006.01.147 ↗
52. 3D real-time micromechanical compressive behaviour of bone-cement interface: experimental and finite element studies10.1016/j.jbiomech.2011.10.011 ↗
53. Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression10.1016/j.jbiomech.2014.09.012 ↗
54. Elastic full-field strain analysis and microdamage progression in the vertebral body from digital volume correlation10.1111/str.12202 ↗
55. Journal of the mechanical behavior of biomedical materials strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement- bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
56. Time-lapsed assessment of microcrack initiation and propagation in murine cortical bone at submicrometer resolution10.1016/j.bone.2009.04.248 ↗
57. Damage accumulation in vertebral trabecular bone depends on loading mode and direction10.1016/j.jbiomech.2011.01.018 ↗
58. Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep model10.1016/j.medengphy.2008.01.007 ↗