journal article·2016-04

Long-term retention behaviour of resin matrix attachment systems for overdentures

Nicole Passia, Muhamad Ghazal, Matthias Kern

Publisher page

Abstract

Objectives The purpose of this laboratory study was to evaluate the long-term retention behaviour of two resin matrix attachment systems for overdentures and the influence of the implant angulation. Methods Sixteen titanium patrices of each attachment system were connected to their corresponding implant analogues and fixed in an auto curing resin either orthogonally (n=8) or 20° tilted (n=8). The corresponding matrices, one made from polyetherketoneketone (PEKK; CM LOC, Cendres+Métaux, Biel, Switzerland), one made from polyethylene (PE; Locator, Zest Anchors, Escondido, California, USA), were fixed in a stylised unilaterally removable dental prosthesis resulting in 4 groups with 8 specimens in each group. Overall, 30,000 joining and separating cycles of the matrix were performed in a chewing simulator. After each joining movement, the unilaterally removable dental prosthesis was loaded eccentrically with 100N at a distance of 12mm from the attachment to simulate clinical loading conditions. Retentive forces were measured during the test using force transducers. The statistical analysis was performed using Tukey-HSD. Results Both attachment systems showed a significant decrease in retention over time, which occurred earlier in the tilted groups than in the orthogonal groups. After 5000-30,000 joining and separating cycles the PE matrix attachment provided significantly lower retention than the PEKK matrix attachment system. Conclusion Within the limitations of this investigation, the combination of a titanium patrix and a matrix made from polyetherketoneketone seems to be a promising material combination for long-term retention, also on tilted implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. A comparative prospective study of splinted and unsplinted Branemark implants in mandibular overdenture therapy: a preliminary report10.1016/0022-3913(94)90188-0 ↗
2. Comparative study of retentive anchor systems for overdentures
3. In vitro retention force changes of prefabricated attachments for overdentures10.1046/j.1365-2842.2003.01140.x ↗
4. Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: a 3-year prospective study
5. Comparison of retention and release periods for implant overdenture attachments
6. Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study
7. The economics of complete dentures and implant-related services: a framework for analysis and preliminary outcomes10.1016/S0022-3913(98)70189-1 ↗
8. Single implant in the middle of the mandible: an update
9. Analysis of retention and wear of ball attachments
10. Investigation of retentive force reduction and wear of the locator attachment system with different implant angulations10.11607/jomi.3687 ↗
11. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures10.11607/jomi.3621 ↗
12. Attachment systems for mandibular implant overdentures: a systematic review10.4047/jap.2012.4.4.197 ↗
13. Comparative study of two precision overdenture attachment designs10.1016/S0022-3913(96)90298-X ↗
14. Retention and wear of precision-type attachments10.1016/0022-3913(83)90233-0 ↗
15. The incomprehensible success of the implant stabilised overdenture in the edentulous mandible: a literature review on transfer of chewing forces to bone surrounding implants
16. Effects of overdenture retention designs and implant orientations on load transfer characteristics10.1016/S0022-3913(96)90441-2 ↗
17. 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study10.1034/j.1600-0501.1996.070413.x ↗
18. The effect of simulated function on the retention of bar-clip retained removable prostheses10.1016/S0022-3913(96)90465-5 ↗
19. Attachment systems for implant retained overdentures: a literature review10.1097/01.id.0000202419.21665.36 ↗
20. Retentive characteristics of overdenture attachments during repeated dislodging and cyclic loading
21. The retentive forces of the locator attachment system at different angulations
22. Retentive characteristics of a vinylpolysiloxane overdenture attachment system10.1007/s00784-014-1307-1 ↗
23. Comparison of tibial insert polyethylene damage in rotating hinge and highly constrained total knee arthroplasty: a retrieval analysis
24. Fracture of the polyethylene tibial post in a posterior stabilized knee prosthesis: a case report and review of literature10.1016/j.jor.2015.01.002 ↗
25. Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study10.1016/S0022-3913(09)60045-7 ↗
26. Effect of implant angulation on attachment retention in mandibular two-implant overdentures: a clinical study10.1111/cid.12030 ↗
27. The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study10.1111/jopr.12144 ↗
28. Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning10.1016/j.dental.2013.12.008 ↗
29. Tribology of polymers: adhesion, friction, wear and mass-transfer10.1016/j.triboint.2005.07.016 ↗
30. Wear of feldspathic ceramic, nano-filled composite resin and acrylic resin artificial teeth when opposed to different antagonists10.1111/j.1600-0722.2008.00573.x ↗
31. Wear of resin denture teeth by two-body contact10.1016/j.dental.2005.03.009 ↗
32. Prosthodontic complications with implant overdentures: a systematic literature review
33. Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment10.1016/S0022-3913(11)60088-7 ↗
34. Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures10.1007/s007840050119 ↗
35. Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems10.1111/clr.12156 ↗
36. Wear simulation effects on overdenture stud attachments10.4012/dmj.2011-057 ↗
37. Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces10.1111/j.1600-0501.2010.02137.x ↗