journal article·2017-03Open access

Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: Local analysis on bone and cement-bone microstructures

Gianluca Tozzi, Enrico Dall’Ara, Marco Palanca, Marco Curto, Federica Innocente, Luca Cristofolini

Abstract

Combination of micro-focus computed tomography (micro-CT) in conjunction with in situ mechanical testing and digital volume correlation (DVC) can be used to access the internal deformation of materials and structures. DVC has been exploited over the past decade to measure complex deformation fields within biological tissues and bone-biomaterial systems. However, before adopting it in a clinically-relevant context (i.e. bone augmentation in vertebroplasty), the research community should focus on understanding the reliability of such method in different orthopaedic applications involving the use of biomaterials. The aim of this study was to evaluate systematic and random errors affecting the strain computed with two different DVC approaches (a global one, "ShIRT-FE", and a local one, "DaVis-DC") in different microstructures within augmented vertebrae, such as trabecular bone, cortical bone and cement-bone interdigitation. The results showed that systematic error was insensitive to the size of the computation sub-volume used for the DVC correlation. Conversely, the random error (which was generally the largest component of error) was lower for a 48-voxel (1872micrometer) sub-volume (64-221 microstrain for ShIRT-FE, 88-274 microstrain for DaVis-DC), than for a 16-voxel (624micrometer) sub-volume (359-1203 microstrain for ShIRT-FE, 960-1771 microstrain for DaVis-DC) for the trabecular and cement regions. Overall, the local random error did not appear to be influenced by either bone microarchitecture or presence of biomaterial. For the 48-voxel sub-volume the global approach was less sensitive to the gradients in grey-values at the cortical surface (random error below 200 microstrain), while the local approach showed errors up to 770 microstrain. Mean absolute error (MAER) and standard deviation of error (SDER) were also calculated and substantially improved when compared to recent literature for the cement-bone interface. The multipass approach for DaVis-DC further reduced the random error for the largest volume of interest. The random error did not follow any recognizable pattern with the six strain components and only ShiRT-FE seemed to produce lower random errors in the normal strains. In conclusion this study has provided, for the first time, a preliminary indication of the reliability and limitations for the application of DVC in estimating the micromechanics of bone and cement-bone interface in augmented vertebrae.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Medical Imaging and Analysis · Spine and Intervertebral Disc Pathology · Bone health and osteoporosis research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
2. A preliminary in vitro biomechanical evaluation of prophylactic cement augmentation of the thoracolumbar vertebrae10.1142/S0219519416500743 ↗
3. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
4. Application of digital volume correlation to study the efficacy of prophylactic vertebral augmentation10.1016/j.clinbiomech.2016.07.010 ↗
5. Reproducible reference frame for in vitro testing of the human vertebrae10.1016/j.jbiomech.2013.10.005 ↗
6. BoneJ: free and extensible bone image analysis in ImageJ10.1016/j.bone.2010.08.023 ↗
7. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
8. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
9. Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra10.1016/j.jbiomech.2013.04.004 ↗
10. New vertebral compression fractures after prophylactic vertebroplasty in osteoporotic patients10.2214/AJR.10.5937 ↗
11. Properties of acrylic bone cement: state of the art review10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
12. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
13. Computation of full-field displacement in a scaffold implant using Digital Volume Correlation and Finite Element10.1016/j.medengphy.2013.02.001 ↗
14. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
15. Use of digital image correlation to investigate the biomechanics of the vertebra10.1142/S0219519415400047 ↗
16. 3D local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
17. Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: an organ-level study10.1016/j.jbiomech.2016.10.018 ↗
18. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
19. Systematic errors in digital image correlation due to undermatched subset shape functions10.1007/BF02410987 ↗
20. 3D real-time micromechanical compressive behaviour of bone-cement interface: experimental and finite element studies10.1016/j.jbiomech.2011.10.011 ↗
21. Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression10.1016/j.jbiomech.2014.09.012 ↗
22. Elastic full-field strain analysis and microdamage progression in the vertebral body from digital volume correlation10.1111/str.12202 ↗
23. Mechanical characterisation of a metallic foam-cement composite under selected loading conditions10.1007/s10856-013-5000-8 ↗
24. Spatial resolution and measurement uncertainty of strains in bone and bone-cement interface using digital volume correlation10.1016/j.jmbbm.2015.12.017 ↗