journal article·2020-07

Topological optimization of 3D printed bone analog with PEKK for surgical mandibular reconstruction

Kang-jie Cheng, Yun-feng Liu, Russell Wang, Jian-xing Zhang, Xian-feng Jiang, Xing-tao Dong, Xu Xu

Publisher page

Abstract

Purpose The purpose of this study was to analyze mechanical behaviors of a topologically optimized and 3D-printed mandibular bone block with polyetherketoneketone (PEKK) for surgical mandibular reconstruction. Materials and methods 3D virtual mandibular models were reconstructed from cone beam computed tomography images. A proposed mandibular resection of the mandibular body (40 mm anterior-posteriorly) was segmented. Internal structure of the resected bone was designed with topological optimization. Dental implants and implant-supported crowns were integrated into the design. A second 3D virtual model was created with the same size and location of the defect but was reconstructed with a fibular graft and implant-supported crowns. The biomechanical behaviors of the two models were compared by finite element method (FEM) under the same boundary constraints and three loading locations, namely, central incisors, lower left and right side first molar areas. Results The FEM results showed the maximum stresses and displacements of the topology optimized model were much lower than those of the model with fibular bone graft. The highest stress of the optimized mandibular model was located on the lower edge of the posterior border of bone analog, and fixation screws. The maximum displacement occurred at the lower edge of the proximal mandibular stump or the lower edge of the distal mandibular body on the contralateral site. Under the same three loading locations, the maximum stress of the optimized model significantly decreased by 67.9%, 71.9% and 68.6% compared to the fibular graft model. Conclusions The 3D printed bone analog with topological optimization is patient-specific and has advantages over the conventional fibular bone graft for surgical mandibular reconstruction. The optimized PEKK bone analog model creates more normal stress-strain trajectories than the fibular graft model and likely provides better functional and cosmetic outcomes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Additive Manufacturing and 3D Printing Technologies · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. The use of vascularized fibula flap in mandibular reconstruction; A comprehensive systematic review and meta-analysis of the observational studies10.1016/j.jcms.2019.01.037 ↗
2. Computer-assisted surgery for reconstruction of complex mandibular defects using osteomyocutaneous microvascular fibular free flaps: use of a skin paddle-outlining guide for soft-tissue reconstruction. A technical report10.1016/j.jcms.2018.11.018 ↗
3. Optimal shape design as a material distribution problem10.1007/BF01650949 ↗
4. Material interpolation schemes in topology optimization
5. Assessment of functional improvement with implant-supported prosthetic rehabilitation after mandibular reconstruction with a microvascular free fibula flap: a study of 25 patients10.1016/j.prosdent.2014.08.005 ↗
6. Osseointegrated implants: a comparative study of bone thickness in four vascularized bone flaps10.1097/00006534-199309000-00010 ↗
7. A new method for computer-aided operation planning for extensive mandibular reconstruction10.1097/01.prs.0000219076.83890.e8 ↗
8. Clinical outcome and patient satisfaction after mandibular reconstruction with free fibula flaps10.1016/j.ijom.2007.04.013 ↗
9. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
10. Intensity of artefacts in cone beam CT examinations caused by titanium and glass fibre-reinforced composite implants10.1259/dmfr.20170471 ↗
11. Comparative evaluation of a four-implant-supported polyetherketoneketone framework prosthesis: a three-dimensional finite element analysis based on cone beam computed tomography and computer-aided design10.11607/ijp.5369 ↗
12. Deformation and energy absorption diagrams for cellular solids10.1016/0001-6160(84)90177-9 ↗
13. Computer assisted chewing power in patients with segmental resection of the mandible10.1007/s10006-005-0656-y ↗
14. Nelson · 1986
15. A large calvarial bone defect in a child: osseointegration of an implant10.1016/j.wneu.2019.01.028 ↗
16. The mechanical properties of poly(ether-ether-ketone) (PEEK) with emphasis on the large compressive strain response10.1016/j.polymer.2006.11.032 ↗
17. Evaluation and reduction of magnetic resonance imaging artifacts induced by distinct paltes for osseous fixation. An in vitro study @ 3 T10.1259/dmfr.20170361 ↗
18. Patient specific glass fiber reinforced composite versus titanium plate. A comparative biomechanical analysis under cyclic dynamic loading10.1016/j.jmbbm.2018.12.014 ↗
19. Relations of mechanical properties to density and CT numbers in human bone10.1016/1350-4533(95)97314-F ↗
20. Accuracy of fibula reconstruction using patient-specific CAD/CAM reconstruction plates and dental implants: a new modality for functional reconstruction of mandibular defects10.1016/j.jcms.2015.03.015 ↗
21. A 99 line topology optimization code written in Matlab10.1007/s001580050176 ↗
22. Comparison of the microtensile bond strength of a polyetherketoneketone (PEKK) tooth post cemented with various surface treatments and various resin cements10.3390/ma11060916 ↗
23. Carbon fiber reinforced PEEK optima—a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
24. Biomechanical evaluation of endodontic post-restored teeth —— finite element analysis10.1142/S0219519413500127 ↗
25. The CAD-CAM technique for mandibular reconstruction: an 18 patients oncological case-series10.1016/j.jcms.2014.04.011 ↗
26. Polyetheretherketone as a biomaterial for spinal applications10.1016/j.biomaterials.2005.07.011 ↗
27. Comparative finite element analysis of the biomechanical stability of 2.0 fixation plates in atrophic mandibular fractures
28. Antibacterial properties of PEKK for orthopedic applications10.2147/IJN.S134983 ↗
29. Mandible reconstruction using patient-specific pre-bent reconstruction plates: comparison of standard and transfer key methods
30. Biomechanics of mandibular reconstruction: a review10.1016/j.ijom.2009.11.003 ↗