Modeling dental implant insertion
Source abstract
Abstract
The success of dental implantation is connected with the so-called implant primary stability, a synonym for the implant anchoring inside the bone. The primary stability is related to the applied peak torque to the implant during the insertion process. This work simulates the process of insertion of a typical commercial implant into the jaw bone (mandible) using a 3D dynamic non-linear finite-elements software. The model considers the geometrical and mechanical properties of the implant, the bone-implant friction, and the insertion procedure parameters, namely angular velocity and normal load. The numerical results assess the influence of those parameters on the evolution of the insertion torque and the resulting bone damage. It is found that, within the model's assumptions, the angular insertion velocity (up to 120rpm) has little or no effect on the process. The application of a normal load, in addition to the implant rotation, enforces an extrusion process in addition to the screwing one. The respective contribution of the cortical and trabecular bone components to the insertion torque reveals that, despite its significantly lower strength, the trabecular bone has a definite contribution to the insertion process. This work shows that if the various physical, geometrical and mechanical parameters of the bone-implant system are well-defined, the insertion process can be simulated prior to the surgical act, and predict, tailor and contribute to maximize the success of dental implantation in a personalized manner.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment10.1111/j.1600-051X.2007.01047.x ↗
2. The mechanical properties of cellular solids10.1007/BF02645546 ↗
3. Methods used to assess implant stability: current status
4. Prediction of dental implant torque with a fast and automatic finite element analysis: a pilot study10.1016/j.tripleo.2009.11.010 ↗
5. A 7-year follow-up of 93 immediately loaded titanium dental implants10.1563/0-730.1 ↗
6. Density and architecture have greater effects on the toughness of trabecular bone than damage10.1016/j.bone.2008.12.030 ↗
7. The mechanical behaviour of cancellous bone10.1016/0021-9290(85)90287-8 ↗
8. Evaluation of dental IMPLANT insertion torque using a manual ratchet10.1016/j.mjafi.2013.07.010 ↗
9. Artificial composite bone as a model of human trabecular bone: the implant-bone interface10.1016/j.jbiomech.2006.04.007 ↗
10. Dynamic modelling and simulation of dental implant insertion process—a finite element study10.1016/j.finel.2011.03.005 ↗
11. Micro-CT finite element model and experimental validation of trabecular bone damage and fracture10.1016/j.bone.2013.06.028 ↗
12. The influence of bone volume fraction and ash fraction on bone strength and modulus10.1016/S8756-3282(01)00467-7 ↗
13. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
14. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation
15. Osseointegration under immediate loading: biomechanical stress–strain and bone formation–resorption10.1097/01.ID.0000034394.75768.E3 ↗
16. Mechanical properties of cortical and trabecular bone
17. An experimental investigation on thermal exposure during bone drilling10.1016/j.medengphy.2012.03.002 ↗
18. Is trabecular bone related to primary stability of miniscrews?10.2319/052513-39.1 ↗
19. A review of implant design, geometry and placement
20. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis10.1034/j.1600-0501.1996.070308.x ↗
21. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study10.1111/j.1708-8208.2000.tb00110.x ↗
22. A novel computational method for real-time preoperative assessment of primary dental implant stability10.1111/j.1600-0501.2004.01071.x ↗
23. Three-year post-placement survival of implants mobile at placement10.1902/annals.2000.5.1.32 ↗
24. Drilling of bone: a comprehensive review10.1016/j.jcot.2013.01.002 ↗
25. Use of stress analysis methods to evaluate the biomechanics of oral rehabilitation with implants
26. The mechanical properties of cortical bone10.2106/00004623-197456050-00012 ↗
27. Bone quality and the immediate loading of implants—critical aspects based on literature, research, and clinical experience10.1097/ID.0b013e3181991248 ↗
28. The periotest method
29. Edentulation alters material properties of cortical bone in the human mandible10.1177/154405910208100907 ↗
30. Simulia · 2014
31. Abaqus/Explicit Version 6.14-2, Abaqus Documentation
32. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K ↗
33. Considerations preliminary to the application of early and immediate loading protocols in dental implantology10.1034/j.1600-0501.2000.011001012.x ↗
34. Step-wise analysis of the dental implant insertion process using the finite element technique10.1111/j.1600-0501.2007.01427.x ↗
35. Experimental analysis of drilling process in cortical bone10.1016/j.medengphy.2013.08.006 ↗