Effect of dissolution/precipitation on the residual stress redistribution of plasma-sprayed hydroxyapatite coating on titanium substrate in simulated body fluid (SBF)
Source abstract
Abstract
The residual stress distributions in hydroxyapatite (HAp) coating with and without mixed hydroxyapatite/titanium (HAp/Ti) bond coating on commercially pure Titanium substrate (cp-Ti) were evaluated by Raman piezo-spectroscopy analysis. The Raman shifted position 962cm(-1), which is the symmetrical stretching of surrounded oxygen atoms with phosphorous atom ( [Formula: see text] ), was referred to analyses of stress dependency. The piezo-spectroscopic coefficient, which is a Raman shift value per stress (cm(-1)/GPa), was fitted from the result of four-points bending test of rectangular HAp bar and as-sprayed HAp on Zn plate. The calculated values were 3.89cm(-1)/GPa for the former and 7.11cm(-1)/GPa for the latter. By using these calibrations, the compressive residual stress in HAp coating with HAp/Ti bond coating (HA-B) has been found to be distributed in the range of -137MPa to -75MPa. For the heat-treated HAp coating (HA-B-HT) specimen, the compressive residual stresses placed in the range of -40--22MPa. The changes in the values of residual stress of the HAp coating after immersion in SBF were also evaluated. The residual stress in HA-WB specimens tend to change from compressive to tensile after 30 days immersion. The HA-B-HT specimens exhibited similar behavior and reached to zero stress after the immersion. The mechanism of the changes in residual stress would be the effect of stress redistribution around melted calcium phosphate particles to remained HAp splats.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Onlay silicone and hydroxyapatite–tricalciumphosphate composite (HAP-TCP) blocks interfere with nasal bone growth in rabbits10.1597/1545-1569_1995_032_0282_osahtc_2.3.co_2 ↗
2. Feature article: calcium phosphate based resorbable ceramics: influence of MgO, ZnO and SiO2 dopants,10.1111/j.1551-2916.2006.01207.x ↗
3. Vibrational spectra of hydrothermally prepared hydroxyapatites10.1111/j.1151-2916.1971.tb12207.x ↗
4. Determination of the piezospectroscopic coefficients for chromium-doped sapphire10.1111/j.1151-2916.1995.tb08493.x ↗
5. Elliot · 1991 · 170
6. Compositional and microstructural changes in engineered plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrates during incubation in protein-free simulated body fluid10.1002/1097-4636(2000)53:6<685::AID-JBM11>3.0.CO;2-B ↗
7. In vitro testing of plasma-sprayed hydroxyapatite coatings10.1007/BF00121092 ↗
8. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength10.1016/0142-9612(94)90241-0 ↗
9. ISO., 2007a 13779-2 Implant for Surgery-Hydroxyapatite- Part 2 Coatings of Hydroxyapatite.
10. ISO., 2007b 13779-4 Implant for surgery-Hydroxyapatite- Part 4 Determination of coating adhesion strength.
11. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants10.1002/jbm.820290104 ↗
12. FT-Raman spectroscopy: a tool for monitoring the demineralization of bones10.1366/0003702001948853 ↗
13. Bone compaction enhanced fixation of weight bearing hydroxyapatite-coated implants10.1016/j.arth.2005.02.015 ↗
14. Acoustic emission and fatigue damage induced in plasma sprayed hydroxyapatite coating layer10.1016/j.jmbbm.2011.11.011 ↗
15. Failure behavior of plasma-sprayed HAp coating on commercially pure titanium substrate in simulatedbody fluid (SBF) under bending load
16. A new concept of gentamicin loaded HAP/TCP bone substitute for prophylactic action: in vitro release validation10.1007/s10856-007-0163-9 ↗
17. Adhesive and bending failure of thermal sprayed hydroxyapatite coatings: effect of nanostructures at interface and crack propagation phenomenon during bending10.1016/j.engfracmech.2006.06.001 ↗
18. Miura, N., Akao, K., Aoki, S., 1985. Thermal expansion of calcium phosphate ceramics. In: Proceedings of the Annual Meeting of the Japanese Society for Dental Materials and Devices Dental Materials Journal. 4 (special issue 5), p. 137.
19. Orthopaedic applications of hydroxyapatite10.1016/0142-9612(91)90196-H ↗
20. Raman piezo-spectroscopic analysis of natural and synthetic biomaterials10.1007/s00216-004-2780-1 ↗
21. Vibrational spectroscopic study of tetracalcium phosphate in pure polycrystalline form and as a constituent of a self-setting bone cement10.1002/(SICI)1097-4636(19980615)40:4<640::AID-JBM16>3.0.CO;2-J ↗
22. Characterization and fatigue damage of plasma sprayed HAp top coat with Ti and HAp/Ti bond coat layers on commercially pure titanium substrate10.1016/j.jmbbm.2008.11.001 ↗
23. Electrochemical depositions of calcium phosphate film on commercial pure titanium and Ti-6Al-4V in two types of electrolyte at room temperature10.1016/j.msec.2008.06.028 ↗
24. The hydroxyapatite-tapered stem: any added value10.1053/j.sart.2011.03.006 ↗
25. Compositionally graded hydroxyapatite tricalcium phosphate coating on Ti by laser and induction plasma10.1016/j.actbio.2010.09.016 ↗
26. Induction plasma sprayed nano hydroxyapatite coatings on titanium for orthopaedic and dental implants10.1016/j.surfcoat.2010.10.042 ↗
27. Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings10.1016/S0142-9612(96)00147-0 ↗
28. The effect of structural characteristics on the in vitro bioactivity of hydroxyapatite10.1002/jbm.10087 ↗
29. Tanaka · 2009
30. Residual stress measurement of an EB-PVD Y2O3–ZrO3 thermal barrier coating by micro-Raman spectroscopy10.1016/j.surfcoat.2009.08.042 ↗
31. Effect of varying HAP/TCP ratios in tape-cast biphasic calcium phosphate ceramics on response in vitro10.2485/jhtb.18.71 ↗
32. Measurement of residual stresses in plasma-sprayed hydroxyapatite coatings on titanium alloy10.1016/j.surfcoat.2004.02.038 ↗