In vitro degradation, flexural, compressive and shear properties of fully bioresorbable composite rods
Source abstract
Abstract
Several studies have investigated self-reinforced polylactic acid (SR-PLA) and polyglycolic acid (SR-PGA) rods which could be used as intramedullary (IM) fixation devices to align and stabilise bone fractures. This study investigated totally bioresorbable composite rods manufactured via compression moulding at ~100 °C using phosphate glass fibres (of composition 50P(2)O(5)-40CaO-5Na(2)O-5Fe(2)O(3) in mol%) to reinforce PLA with an approximate fibre volume fraction (v(f)) of 30%. Different fibre architectures (random and unidirectional) were investigated and pure PLA rods were used as control samples. The degradation profiles and retention of mechanical properties were investigated and PBS was selected as the degradation medium. Unidirectional (P50 UD) composite rods had 50% higher initial flexural strength as compared to PLA and 60% higher in comparison to the random mat (P50 RM) composite rods. Similar initial profiles for flexural modulus were also seen comparing the P50 UD and P50 RM rods. Higher shear strength properties were seen for P50 UD in comparison to P50 RM and PLA rods. However, shear stiffness values decreased rapidly (after a week) whereas the PLA remained approximately constant. For the compressive strength studies, P50 RM and PLA rods remained approximately constant, whilst for the P50 UD rods a significantly higher initial value was obtained, which decreased rapidly after 3 days immersion in PBS. However, the mechanical properties decreased after immersion in PBS as a result of the plasticisation effect of water within the composite and degradation of the fibres. The fibres within the random and unidirectional composite rods (P50 RM and P50 UD) degraded leaving behind microtubes as seen from the SEM micrographs (after 28 days degradation) which in turn created a porous structure within the rods. This was the main reason attributed for the increase seen in mass loss and water uptake for the composite rods (~17% and ~16%, respectively).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. ASTM D2584-94, 1994. Standard Test Method for Ignition Loss of Cured Reinforced Resins.
2. A facile synthesis route to prepare microtubes from phosphate glass fibres10.1002/adma.200700039 ↗
3. Processing, characterisation and biocompatibility of iron-phosphate glass fibres for tissue engineering10.1016/j.biomaterials.2003.10.013 ↗
4. Retention of mechanical properties and cytocompatibility of a phosphate-based glass fiber/polylactic acid composite10.1002/jbm.b.31182 ↗
5. Cytocompatibility and effect of increasing MgO content in a range of quaternary invert phosphate-based glasses10.1177/0885328209102761 ↗
6. Degradable phosphate glass fiber reinforced polymer matrices: mechanical properties and cell response
7. BS 2782-3: Methods 340A and 340B, 1978. Methods of testing plastics. Mechanical properties. Determination of shear strength of moulding material. Determination of shear strength of sheet material.
8. BS 2782-10: Method 1008B:1996, ISO 3597-2:1993, Methods of testing plastics. Glass reinforced plastics. Determination of flexural strength on rods made of roving-reinforced resin.
9. BS ISO 3597-3, 2003. Textile-glass-reinforced plastics. Determination of mechanical properties on rods made of roving-reinforced resin. Determination of compressive strength.
10. BS EN ISO 10993-13, 2010. Biological evaluation of medical devices. Identification and quantification of degradation products from polymeric medical devices.
11. Chad Munro, M.C., 2010. Intramedullary rod with vent. USA.
12. Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone10.1002/jab.770010109 ↗
13. Investigation of crystallinity, molecular weight change, and mechanical properties of PLA/PBG bioresorbable composites as bone fracture fixation plates
14. Biodegradation behavior of ultra-high-strength hydroxyapatite/poly (-lactide) composite rods for internal fixation of bone fractures10.1016/S0142-9612(99)00232-X ↗
15. Self-reinforcement and hydrolytic degradation of amorphous lactic acid based poly(ester-amide), and of its composite with sol–gel derived fibers
16. Influence of compatibilizing agent molecular structure on the mechanical properties of phosphate glass fiber-reinforced PLA composites. Journal of Polymer Science Part A10.1002/pola.24086 ↗
17. Interfacial properties of phosphate glass fibres/PLA composites: effect of the end functionalities of oligomeric PLA coupling agents10.1016/j.compscitech.2010.06.012 ↗
18. A 5–7 year in vivo study of high-strength hydroxyapatite/poly(l-lactide) composite rods for the internal fixation of bone fractures10.1016/j.biomaterials.2005.09.003 ↗
19. A totally bioresorbable fibrillar reinforced composite system: structure and properties
20. Biodegradable ultra high strength poly(L-lactide) rods for bone fixation10.1002/masy.200350731 ↗
21. Lin, S., Krebs, S., Nazre, A., King, R., 1994. Totally Bioabsorbable composites, in 39th International SAMPE Symposium. p. 1981–1985.
22. Degradability of polymers for implantable biomedical devices10.3390/ijms10094033 ↗
23. Absorbable self-reinforced polylactide (SR–PLA) composite rods for fracture fixation: strength and strength retention in the bone and subcutaneous tissue of rabbits
24. Maruyama, T., Saha, S., Mongiano, D.O., Mudge, K., 1995. A biomechanical evaluation of metacarpal fracture fixation with absorbable polyglycolide rods, in: Biomedical Engineering Conference. Proceedings of the 1995 Fourteenth Southern. 1995.
25. Phosphate glass fibre composites for bone repair10.1016/S1672-6529(08)60132-8 ↗
26. Synthesis and degradation of sodium iron phosphate glasses and their 〈I〉in vitro〈/I〉 cell response10.1002/jbm.a.30161 ↗
27. Strength requirements for internal and external prostheses10.1016/S0021-9290(98)00190-0 ↗
28. Pertti, T., Pentti, R., Juha, L., Markku, T., Seppo, V., 1988. Material for osteosynthesis devices, US Patent, Editor: United States.
29. Pietrzak, W.S., Caminear, D.S., Perns, S.V., Mechanical characteristics of an absorbable copolymer internal fixation pin. The Journal of Foot and Ankle Surgery 41 (6), pp. 379–388.10.1016/S1067-2516(02)80084-9 ↗
30. Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods. An experimental study on rats
31. Review article. The mechanical properties of cortical bone
32. Pullout strengths of self-reinforced Poly-L-Lactide (SR–PLLA) rods versus kirschner wires in bovine femur10.1097/00005131-200108000-00008 ↗
33. Influence of calcium phosphates on the degradation of poly lactic acid for medical implants10.1515/bmte.1996.41.s1.420 ↗
34. Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly -lactide (PLLA). Part II: practical properties of miniscrews and miniplates10.1016/S0142-9612(01)00072-2 ↗
35. Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly–lactide (PLLA): Part I. Basic characteristics10.1016/S0142-9612(98)00241-5 ↗
36. Törmälä · 2010
37. Bioabsorbable polymers: materials technology and surgical applications10.1243/0954411981533872 ↗
38. Ultra-high-strength absorbable self-reinforced polyglycolide (SR–PGA) composite rods for internal fixation of bone fractures: in vitro and in vivo study10.1002/jbm.820250102 ↗
39. Strength and strength retention in vitro, of absorbable, self-reinforced polyglycolide (PGA) rods for fracture fixation10.1016/0142-9612(87)90028-7 ↗
40. Biodegradable self-reinforced polyglycolide (SR–PGA) composite rods coated with slowly biodegradable polymers for fracture fixation: strength and strength retention in vitro and in vivo