The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion
Source abstract
Abstract
Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental over-tightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/ stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2N/mm (cortical screws) and 13.4N/mm (cancellous screws) in sawbone blocks and 20.9N/mm (cortical screws) and 6.1N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4N/mm (cortical screws) and 16.8N/mm (cancellous screws) in sawbone blocks and 29.3N/mm (cortical screws) and 8.3N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the effect of sawbone density or human bone sBMD on stopping and stripping torque.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone fractures and treatments · Hip and Femur Fractures · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. The Biomechanics of Three Different Fracture Fixation Implants for Distal Femur Repair in the Presence of a Tumor-like Defect10.1177/0954411912454368 ↗
2. Concurrent ipsilateral fractures of the hip and shaft of the femur: a systematic review of 722 cases
3. Operative stabilization of supracondylar femur fractures above total knee arthroplasty: a comparison of four treatment methods10.1016/S0883-5403(03)00339-5 ↗
4. A study of some factors which affect the strength of screws and their insertion and holding power in bone10.1016/0021-9290(68)90023-7 ↗
5. Limb bone bilateral asymmetry: variability and commonality among modern humans10.1016/j.jhevol.2005.09.004 ↗
6. Comparison of torque measurements between cortical screws and emergency replacement screws in the cadaver mandible10.1016/0278-2391(92)90195-6 ↗
7. Comparative left–right mechanical testing of cancellous bone from normal femoral heads10.1016/0021-9290(96)00061-9 ↗
8. Contributors to secondary osteoporosis and metabolic bone diseases in patients presenting with a clinical fracture10.1210/jc.2010-2135 ↗
9. Torque and pullout analysis of six currently available self-tapping and emergency screws10.1016/S0278-2391(10)80389-1 ↗
10. Evaluation of emergency screws in nonstripped pilot holes in bone
11. Comparison between uniaxial pull-out tests and torque measurement of 2.0-mm self-tapping screws
12. 2001
13. Factors affecting the pullout strength of cancellous bone screws10.1115/1.2796022 ↗
14. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty10.1002/jor.1100100314 ↗
15. Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading10.1016/j.medengphy.2003.10.006 ↗
16. Effect of screw torque level on cortical bone pullout strength10.1097/BOT.0b013e318030261e ↗
17. Human torque control in the use of bone screws
18. Stripping of the bone screws at insertion. The relation of torque and angular displacement in predicting admissible torque values
19. Biomechanical measurements of axial crush injury to the distal condyles of human and synthetic femurs10.1177/0954411912438038 ↗
20. Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses
21. Evaluation of compression generated by self compressing orthofix bone pins and lag screws in simulated lateral humeral condylar fractures10.1160/VCOT-06-07-0057 ↗
22. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques10.1054/arth.2000.4339 ↗
23. Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study10.1016/j.jmbbm.2012.09.005 ↗
24. Stripping torque as a predictor of successful internal fracture fixation10.1111/j.1445-2197.2005.03497.x ↗
25. Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty. A basic science and clinical study10.1097/00003086-199212000-00007 ↗
26. Fulkerson, E., Egol, K., Preston, C., Iesaka, K., Kummer, F., Koval, K., 2004, Fixation of periprothetic femoral shaft fractures: a biomechanical comparison of locked plating and conventional cable plates (Ogden Construct). In: Proceedings of the Orthopedic Trauma Association 20th Annual Meeting, Florida, USA.10.1097/01.bot.0000199119.38359.96 ↗
27. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates10.1097/01.bot.0000199119.38359.96 ↗
28. Structural properties of a new design of composite replicate femurs and tibias10.1016/S0021-9290(01)00015-X ↗
29. Heiner, A.D., Brown, T.D., 2003. structural properties of an improved redesign of composite replicate femurs and tibias. In: Proceedings of the Transactions 29th Annual Meeting of the Society for Biomaterials, 26, p. 702.
30. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses,10.1016/j.orthres.2004.11.002 ↗
31. Biomechanics of bone
32. Periprosthetic femoral fractures10.5435/00124635-199405000-00005 ↗
33. Interobserver reliability of the young-burgess and tile classification systems for fractures of the pelvic ring10.1097/BOT.0b013e31817440cf ↗
34. Caudo-cephalad loading of pedicle screws:mechanisms of loosening and methods of augmentation10.1097/00007632-199312000-00012 ↗
35. Effect of insertion torque on bone screw pullout strength10.3928/0147-7447-20010501-12 ↗
36. Bending strength and holding power of a prototype tibial locking screw10.1097/00003086-200210000-00034 ↗
37. Bending strength and holding power of tibial locking screws10.1097/00003086-200104000-00031 ↗
38. The epidemiology of fractures of the distal femur10.1016/S0020-1383(00)80034-0 ↗
39. A fatigue life analysis of small fragment screws10.1097/00005131-200109000-00006 ↗
40. Biomechanical measurements of cortical screw stripping torque in human versus artificial femurs10.1177/0954411912450998 ↗
41. The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour10.1177/0954411911420004 ↗
42. Fractures beneath hip prostheses: a special indication for parham bands and plating
43. A biomechanical comparison of epiphyseal versus metaphyseal fixed bone-conserving hip arthroplasty10.2106/JBJS.J.01709 ↗
44. A comparison of screw insertion torque and pullout strength10.1097/BOT.0b013e3181c4a655 ↗
45. Biomechanical properties of canine cortical bone allografts: effects of preparation and storage10.2460/ajvr.1988.49.06.873 ↗
46. Sawbones. Vashon, WA, USA. 〈http://www.sawbones.com/catalog/pdf/us_catalog.pdf〉.
47. Effect of sterilization and storage treatments on screw pullout strength in human allograft bone10.1097/00003086-199405000-00044 ↗
48. Tencer · 1994
49. Automated surgical screwdriver: automated screw placement10.1243/09544119JEIM375 ↗
50. 2008
51. Biomechanical measurements of torsion-tension coupling in human cadaveric femurs10.1115/1.4002937 ↗
52. A Biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model
53. Cortical screw purchase in synthetic and human femurs10.1115/1.3194755 ↗
54. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis10.1243/09544119JEIM409 ↗
55. Biomechanical evaluation of periprosthetic femoral fracture fixation