Constitutive modeling of porcine liver in indentation using 3D ultrasound imaging
Source abstract
Abstract
In this work we present an inverse finite-element modeling framework for constitutive modeling and parameter estimation of soft tissues using full-field volumetric deformation data obtained from 3D ultrasound. The finite-element model is coupled to full-field visual measurements by regularization springs attached at nodal locations. The free ends of the springs are displaced according to the locally estimated tissue motion, and the normalized potential energy stored in all springs serves as a measure of model-experiment agreement for material parameter optimization. We demonstrate good accuracy of estimated parameters and consistent convergence properties on synthetically generated data. We present constitutive model selection and parameter estimation for perfused porcine liver in indentation, and demonstrate that a quasilinear viscoelastic model with shear modulus relaxation offers good model-experiment agreement in terms of indenter displacement (0.19 mm RMS error) and tissue displacement field (0.97 mm RMS error).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Automotive and Human Injury Biomechanics · Bone health and osteoporosis research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Registration of mr prostate images with biomechanical modeling and nonlinear parameter estimation10.1118/1.2163391 ↗
2. Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery10.1016/j.neuroimage.2006.11.060 ↗
3. Material property differentiation in indentation testing using secondary sensors10.1007/s11340-007-9087-z ↗
4. Application of soft tissue modelling to image-guided surgery10.1016/j.medengphy.2005.10.005 ↗
5. Concepts and preliminary data toward the realization of image-guided liver surgery10.1007/s11605-007-0090-6 ↗
6. Robust nonrigid registration to capture brain shift from intraoperative MRI10.1109/TMI.2005.856734 ↗
7. Needle steering and motion planning in soft tissues10.1109/TBME.2005.846734 ↗
8. Inverse parameter fitting of biological tissues: A response surface approach10.1007/s10439-005-8338-3 ↗
9. Measuring soft tissue properties using digital image correlation and finite element modelling
10. Fung · 1993
11. Are in vivo and in situ brain tissues mechanically similar?10.1016/j.jbiomech.2003.12.032 ↗
12. Hibbit, Karlsson, Sorensen · 2007
13. Holzapfel · 2000
14. Modular nonrigid image registration framework using nonlinear mechanical regularization (in review)
15. Kerdok, A.E., 2006. Characterizing the nonlinear mechanical response of liver to surgical manipulation. Ph.D. Thesis, Harvard University
16. Effects of perfusion on the viscoelastic characteristics of liver10.1016/j.jbiomech.2005.07.005 ↗
17. Convergence properties of the Nelder-Mead simplex method in low dimensions10.1137/S1052623496303470 ↗
18. Optical flow estimation using high frame rate sequences
19. Lucas, B.D., Kanade, T., 1981. An iterative image registration technique with an application to stereo vision. In: Proceedings of the 7th International Joint Conference on Artificial Intelligence (IJCAI ’81). pp. 674–679
20. The mechanical response of human liver and its relation to histology: An in vivo study10.1016/j.media.2007.06.010 ↗
21. Method of testing very soft biological tissues in compression10.1016/j.jbiomech.2004.03.004 ↗
22. Constitutive modelling of brain tissue: Experiment and theory10.1016/S0021-9290(97)00092-4 ↗
23. Mechanical properties of brain tissue in-vivo: Experiment and computer simulation10.1016/S0021-9290(00)00120-2 ↗
24. In vivo mechanical characterization of human liver
25. Indentation analysis of biphasic articular cartilage: Nonlinear phenomena under finite deformation10.1115/1.2895700 ↗
26. Zhu · 1998
27. Zienkiewicz · 1977